If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-005-30881 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.780206,"lon":-79.561142,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Armstrong | |
Municipality: North Buffalo Township | |
Operator Name: MDS ENERGY DEV LLC | |
Well Pad ID: 146599 | |
Farm/Lease Name: MICHAEL SHANEOUR ETUX 1M-20 | |
License Status: | |
Spud Date: | |
Permit Date: 2011-09-14 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Vertical Well | |
Conservation: Yes | |
Latitude: 40.780206 | |
Longitude: -79.561142 |
Date | Event |
---|---|
2011-09-14 | New Permit Application |
2012-09-28 | Permit Renewal Application |
2013-02-21 | Performed Spud Operation |
2013-07-29 | Drilling Completion |
2013-08-14 | Perforation |
2015-11-06 | NEWLY DRILLED |
For data sources see[4]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2013-08-15 | 2013-08-16 | 6,898 | 156,916 | 0 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | HCL Acid (0%-7.5%) | Nabors Completion and Production Services | Bulk Acid | Hydrogen Chloride | 7647-01-0 | 7 | 0.012198 | 0 |
HCl Acid (12.5%-18.0%) | Nabors Completion and Production Services | Bulk Acid | Hydrogen Chloride | 7647-01-0 | 16 | 0.031565 | 0 | |
Super 100 NE | Nabors Completion and Production Services | Surfactants & Foamers | Methyl Alcohol | 67-56-1 | 15 | 0.020813 | 0 | |
Isopropyl Alcohol | 67-63-0 | 40 | 0.055501 | 0 | ||||
2-Butoxyethanol | 111-76-2 | 5 | 0.006938 | 0 | ||||
N-Cocoamidopropyl-N,N-dimethyl-N-2-hydroxypropylsulfobetaine |
68139-30-0 | 15 | 0.020813 | 0 | ||||
Nitrogen per MSCF | Nabors Completion and Production Services | Nitrogen Materials | Nitrogen | 7727-37-9 | 100 | 27.9916 | 0 | |
KR-153SL | Nabors Completion and Production Services | Biocides | 2,2-dibromo-3-nitrilopropionamide | 10222-01-2 | 20 | 0.001282 | 0 | |
Polyethlyene-Glycol | 25322-68-3 | 50 | 0.003206 | 0 | ||||
Water | MDS Energy LTD | Water | Water | 7732-18-5 | 100 | 51.5937 | 0 | |
Sand | Nabors Completion and Production Services | Sand - Bulk - Pennsylvania | Crystalline Silica, quartz | 14808-60-7 | 99.9 | 19.7594 | 0 | |
Acid Inhibitor 2 (AI-2) | Nabors Completion and Production Services | Acid Corrosion Inhibitors | Tar bases, quinoline derivs, benzyl chloride-quaternized | 72480-70-7 | 10 | 0.00009800 | 0 | |
Ethoxylated Nonylphenol | 68412-54-4 | 13 | 0.000127 | 0 | ||||
Glycol Ethers | 111-46-6 | 40 | 0.000391 | 0 | ||||
Isopropyl Alcohol | 67-63-0 | 40 | 0.000391 | 0 | ||||
Propargyl Alcohol | 107-19-7 | 40 | 0.000391 | 0 | ||||
ICP-1000 | Nabors Completion and Production Services | Iron Control Additives | Anionic Copolymer | Proprietary | 50 | 0.005746 | 0 | |
Propylene glycol | 57-55-6 | 50 | 0.005746 | 0 | ||||
Other Ingredients | Nabors Completion and Production Services | Other Ingredients | Proprietary | Proprietary | 50 | 0.00281332 | 0 | |
Proprietary | Proprietary | 15 | 0.000843888 | 0 | ||||
Polymer | Proprietary | 1 | 0.00146417 | 0 | ||||
Anionic Polyacrylamide | 910644-97-2 | 40 | 0.0403765 | 0 | ||||
Water | 7732-18-5 | 50 | 0.0732086 | 0 | ||||
Water | 7732-18-5 | 48 | 0.000478382 | 0 | ||||
Ammonium salts | Proprietary | 100 | 0.0292834 | 0 | ||||
Proprietary | Proprietary | 100 | 0.146417 | 0 | ||||
Propylene glycol | 57-55-6 | 15 | 0.0151416 | 0 | ||||
Phosphoric Acid | 7664-38-2 | 100 | 0.00146417 | 0 | ||||
Water | 7732-18-5 | 60 | 0.00337555 | 0 | ||||
Water | 7732-18-5 | 80 | 0.00489562 | 0 | ||||
2-Butoxyethanol | 111-76-2 | 13 | 0.000129002 | 0 | ||||
ammonium, (2-Hydroxyethyl)trimethyl-, chloride | 67-48-1 | 80 | 0.000581584 | 0 | ||||
Monoethanolamine | Proprietary | 100 | 0.00146417 | 0 | ||||
Proprietary | Proprietary | 1 | 0.00146417 | 0 | ||||
Demineralized Water | 7732-18-5 | 50 | 0.000363355 | 0 | ||||
Water | 7732-18-5 | 87.5 | 0.153995 | 0 | ||||
Alkyl Phosphate Ether | Proprietary | 1 | 0.00146417 | 0 | ||||
Proprietary | Proprietary | 2 | 0.00201888 | 0 | ||||
Water | 7732-18-5 | 40 | 0.0403765 | 0 | ||||
Solvent | Proprietary | 1 | 0.00146417 | 0 | ||||
Polymer | Proprietary | 10 | 0.0146417 | 0 | ||||
Dioxane | 123-91-1 | 1 | 0.00000968 | 0 | ||||
WFR-3B | Nabors Completion and Production Services | Friction Reducer | Propylene Glycol | 57-55-6 | 25 | 0.025123 | 0 | |
Ethoxylated alcohols | 68002-97-1 | 4 | 0.00402 | 0 | ||||
Mineral Spirits | 8052-41-3 | 10 | 0.010049 | 0 | ||||
Hydrotreated light distillates, non-aromatic, BTEX free | 64742-47-8 | 30 | 0.030148 | 0 |
For data sources see[5]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2011 | MDS ENERGY LTD | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2012 | MDS ENERGY LTD | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2013 | MDS ENERGY DEV LLC | 27,508.00 | 72 | 0.00 | 0 | 0.00 | 0 |
2014 | MDS ENERGY DEV LLC | 60,990.00 | 364 | 0.00 | 0 | 0.00 | 0 |
2015 | MDS ENERGY DEV LLC | 33,000.70 | 350 | 0.00 | 0 | 0.00 | 0 |
2016 | MDS ENERGY DEV LLC | 23,630.90 | 345 | 0.00 | 0 | 0.00 | 0 |
2017 | MDS ENERGY DEV LLC | 20,923.20 | 355 | 0.00 | 0 | 0.00 | 0 |
2018 | MDS ENERGY DEV LLC | 16,957.00 | 357 | 0.00 | 0 | 0.00 | 0 |
2019 | MDS ENERGY DEV LLC | 16,036.00 | 351 | 0.00 | 0 | 0.00 | 0 |
For data sources see[6]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2013 | MDS ENERGY DEV LLC | Fracing Fluid Waste | 2,355.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NW006 |
2013 | MDS ENERGY DEV LLC | Produced Fluid | 286.00 Bbl | INJECTION DISPOSAL WELL | 34-155-23223 |
2014 | MDS ENERGY DEV LLC | Produced Fluid | 112.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NW009 |
For data sources see[7]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2108010 | Primary Facility | 2012-10-12 | Routine/Complete Inspection | No Violations Noted | Site had been constructed as outlined in the E&S plan. There was no evidence of accelerated erosion or sedimentation in relation to the access road or well-site. |
2140000 | Primary Facility | 2013-02-14 | Routine/Complete Inspection | No Violations Noted | Site had been constructed but had not been drilled. Perimeter E&S controls were installed in accordance with the on-site E&S plan. Pit had been dug and the pit liner appeared to be in good condition. No erosion issues were apparent. |
2149664 | Primary Facility | 2013-03-18 | Drilling/Alteration | No Violations Noted | Well spud in. Pit lined and freeboard maintained. |
2161262 | Primary Facility | 2013-04-24 | Routine/Complete Inspection | No Violations Noted | Drilling was not ongoing at the time of the inspection. Site and access road controls had been implemented properly and there was no observed evidence of accelerated erosion or sedimentation in relation to the site or access road. Drill pit located onsite and it contained a small amount of fluids. Pit had more than the required two feet of lined freeboard. |
2178224 | Primary Facility | 2013-06-26 | Routine/Complete Inspection | No Violations Noted | Drilling was not ongoing at the time of the inspection. Site and access road controls had been implemented properly and there was no observed evidence of accelerated erosion or sedimentation in relation to the site or access road. Drill pit located onsite and it contained a small amount of fluids. Pit had more than the required two feet of lined freeboard. Production equipment was observed onsite, this included brine tanks which appeared to be in sound condition. |
2187857 | Primary Facility | 2013-07-31 | Drilling/Alteration | No Violations Noted | Waiting on frac. Well shut in on 4 1/2” x 2” swage. 7” x 4 1/2” annulus open. Slight expression of gas at base of wellhead. Pit lined and freeboard maintained. Inspection conducted w/OGI D. Catalano. |
2236066 | Primary Facility | 2014-01-14 | Routine/Complete Inspection | No Violations Noted | Well appeared to be equipped for production. Brine tanks located onsite and they appeared to be in sound condition. Site had been regraded and temporarily stabilized. The operator should monitor the site to insure that 70% uniform coverage is achieved. There was no observed accelerated erosion or sedimentation in relation to the site or access road. |
2266948 | Primary Facility | 2014-04-30 | Routine/Complete Inspection | No Violations Noted | Well appeared to be equipped for production, brine tanks located onsite. Brine tanks appeared to be in sound condition. Site had been regraded, seeded, mulched and the vegetation had begun to emerge. The operator should continue to monitor the site to insure that the vegetation begins to take hold. |
2348573 | Primary Facility | 2015-03-02 | Routine/Complete Inspection | No Violations Noted | Well appeared to be equipped for production. There was no observed accelerated erosion or sedimentation in relation to the site or access road. Brine tanks located onsite and they appeared to be in sound condition. |
For data sources see[8]