37-005-30915

Well Details

Well ID: 37-005-30915
Loading map...
Country: United States
State: Pennsylvania
County: Armstrong
Municipality: Rayburn Township
Operator Name: EXCO RESOURCES PA LLC
Well Pad ID: 149253
Farm/Lease Name: SCHRECENGOST PAD 8 UNIT 1H
License Status:
Spud Date:
Permit Date: 2011-09-29
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: Yes
Latitude: 40.825117
Longitude: -79.475525

For data sources see[1][2][3]

Well History

Date Event
2011-09-29 New Permit Application
2012-01-19 Performed Spud Operation

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2012-05-27 2012-05-27 6,730 4,679,925

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 DAP-901 Calfrac Well Services Scale Inhibitor
DWP-612 Calfrac Well Services Friction Reducer
Water BaseFluid/Mix Water Water 7732-18-5 100.00 84.92
Sand (Proppant) Calfrac Well Services Propping Agent
Hydrochloric Acid Calfrac Well Services Clean Perforations Propargyl Alcohol 10.00 0.00014000
Acetic acid 64-19-7 1.00 0.00019000
Citric acid 77-92-9 60.00 0.00303000
Ilmenite (FeTiO3), conc. 98072-94-7 0.10 0.00153000
Sodium chloride 7647-14-5 1.00 0.00001000
Polyethylene glycol 25322-68-3 70.00 0.01
Quartz 14808-60-7 100.00 14.65
Biotite 1302-27-8 0.10 0.00285000
Polyacrylamide polymer 40.00 0.03
Hydrochloric acid 7647-01-0 37.00 0.30
Nonionic surfactant 5.00 0.00384000
Amine salt 5.00 0.00093000
Goethite 1310-14-1 0.10 0.00548000
Illite 12173-60-3 1.00 0.00414000
Methanol 67-56-1 60.00 0.00646000
Apatite 64476-38-6 0.10 0.00285000
Formalin 50-00-0 0.10 0.00003000
Oxyalkylated polyamine 5.00 0.00093000
Ammonium chloride 12125-02-9 10.00 0.00112000
Fatty acids 30.00 0.00043000
Olefin 5.00 0.00007000
Carbonic acid calcium salt (1:1) 471-34-1 1.00 0.02
2,2-Dibromo-3-nitrilopropionamide 10222-01-2 40.00 0.01
Polyoxyalkylenes 30.00 0.00043000
Distillates, petroleum, hydrotreated light 64742-47-8 30.00 0.02
Organic phosphonate 2 10.00 0.00186000
Polyoxyalkylenes surfactant 5.00 0.00384000
Thiourea polymer 68527-49-1 30.00 0.00043000
Organic phosphonate 1 30.00 0.00559000
DWP-944 Calfrac Well Services Biocide
DAP-103 Calfrac Well Services Iron Control

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2011 EXCO RESOURCES PA LLC 0.00 0 0.00 0 0.00 0
2012 EXCO RESOURCES PA LLC 371,737.00 124 0.00 0 0.00 0
2013 EXCO RESOURCES PA LLC 834,877.00 365 0.00 0 0.00 0
2014 EXCO RESOURCES PA LLC 555,726.00 365 0.00 0 0.00 0
2015 EXCO RESOURCES PA LLC 428,042.00 365 0.00 0 0.00 0
2016 EXCO RESOURCES PA LLC 383,333.00 358 0.00 0 0.00 0
2017 EXCO RESOURCES PA LLC 338,203.00 361 0.00 0 0.00 0
2018 EXCO RESOURCES PA LLC 258,536.00 324 0.00 0 0.00 0
2019 EXCO RESOURCES PA LLC 270,243.00 365 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2012 EXCO RESOURCES PA LLC Produced Fluid 2,762.30 Bbl INJECTION DISPOSAL WELL PAS2D205BCLE
2012 EXCO RESOURCES PA LLC Drilling Fluid Waste 3,199.04 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE EPA ID: 748-163
2012 EXCO RESOURCES PA LLC Produced Fluid 2,358.00 Bbl INJECTION DISPOSAL WELL 34-013-20611
2012 EXCO RESOURCES PA LLC Produced Fluid 435.87 Bbl REUSE OTHER THAN ROAD SPREADING
2012 EXCO RESOURCES PA LLC Drill Cuttings 733.35 Tons LANDFILL 100434
2012 EXCO RESOURCES PA LLC Fracturing Fluid Waste 29.07 Tons LANDFILL 100585
2012 EXCO RESOURCES PA LLC Produced Fluid 108.55 Bbl INJECTION DISPOSAL WELL 34-119-27350
2012 EXCO RESOURCES PA LLC Produced Fluid 105.21 Bbl ROAD SPREADING
2012 EXCO RESOURCES PA LLC Drill Cuttings 83.12 Tons LANDFILL 100585
2012 EXCO RESOURCES PA LLC Produced Fluid 1,043.65 Bbl STORAGE PENDING DISPOSAL OR REUSE
2012 EXCO RESOURCES PA LLC Fracing Fluid Waste 6,590.00 Bbl STORAGE PENDING DISPOSAL OR REUSE
2013 EXCO RESOURCES PA LLC Produced Fluid 35.07 Bbl INJECTION DISPOSAL WELL 34-013-20611
2013 EXCO RESOURCES PA LLC Produced Fluid 662.99 Bbl REUSE OTHER THAN ROAD SPREADING
2013 EXCO RESOURCES PA LLC Produced Fluid 4,766.43 Bbl INJECTION DISPOSAL WELL PAS2D205BCLE
2014 EXCO RESOURCES PA LLC Produced Fluid 3,921.07 Bbl INJECTION DISPOSAL WELL PAS2D205BCLE
2015 EXCO RESOURCES PA LLC Produced Fluid 3,191.50 Bbl INJECTION DISPOSAL WELL PAS2D205BCLE
2016 EXCO RESOURCES PA LLC Produced Fluid 2,327.50 Bbl INJECTION DISPOSAL WELL PAS2D205BCLE
2016 EXCO RESOURCES PA LLC Produced Fluid 208.70 Bbl REUSE OTHER THAN ROAD SPREADING
2017 EXCO RESOURCES PA LLC Produced Fluid 2,289.00 Bbl INJECTION DISPOSAL WELL PAS2D205BCLE
2017 EXCO RESOURCES PA LLC 1,609.10 Bbl INJECTION DISPOSAL WELL PAS2D205BCLE
2017 EXCO RESOURCES PA LLC Produced Fluid 101.90 Bbl REUSE (AT WELL PAD)
2017 EXCO RESOURCES PA LLC 101.90 Bbl REUSE (AT WELL PAD)
2018 EXCO RESOURCES PA LLC Produced Fluid 106.90 Bbl INJECTION DISPOSAL WELL 34-007-21847
2018 EXCO RESOURCES PA LLC Produced Fluid 1,591.60 Bbl INJECTION DISPOSAL WELL PAS2D205BCLE
2019 EXCO RESOURCES PA LLC Produced Fluid 1,512.70 Bbl INJECTION DISPOSAL WELL PAS2D205BCLE

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2032438 Primary Facility 2012-01-03 Drilling/Alteration No Violations Noted not drilled
2034760 Primary Facility 2012-01-10 Drilling/Alteration No Violations Noted not drilled
2038355 Primary Facility 2012-01-18 Drilling/Alteration No Violations Noted not drilled
2038360 Primary Facility 2012-01-24 Drilling/Alteration No Violations Noted
2038374 Primary Facility 2012-01-24 Drilling/Alteration No Violations Noted performing balance cement procedure on mine protective casing
2056809 Primary Facility 2012-04-03 Drilling/Alteration No Violations Noted @ 3915'
2076820 Primary Facility 2012-06-15 Routine/Complete Inspection No Violations Noted operating thru flow back sysytem
2077669 Primary Facility 2012-06-20 Routine/Complete Inspection No Violations Noted Drilling was not ongoing at the time of the inspection. Wells were in the process of being equipped for production. Frac flowback and the freshwater impoundment contained fluids and both had more than the required two feet of lined freeboard. Work was underway to equip the wells onsite for production. Brine tanks were installed, and appeared to be in sound condition. Six frac tanks were located onsite and there was no visible evidence of any spills or leaks related to the frac tanks. Site and access road erosion controls had been implemented and maintained properly.
2086793 Primary Facility 2012-07-27 Routine/Complete Inspection No Violations Noted Drilling was completed, well appeared to be equipped for production. Frac flowback and the freshwater impoundment contained fluids and both had more than the required two feet of lined freeboard. Brine tanks were installed, and appeared to be in sound condition. Brine tank diking was installed. Site and access road erosion controls had been implemented and maintained properly.
2101387 Primary Facility 2012-09-20 Routine/Complete Inspection No Violations Noted Drilling was completed, well appeared to be equipped for production. Frac flowback and the freshwater impoundment contained fluids and both had more than the required two feet of lined freeboard. Brine tanks were installed, and appeared to be in sound condition. Brine tank diking was installed. Site and access road erosion controls had been implemented and maintained properly.
2105779 Primary Facility 2012-10-04 Routine/Complete Inspection No Violations Noted operating
2148883 Primary Facility 2013-03-18 Routine/Complete Inspection No Violations Noted Drilling was completed, well appeared to be equipped for production. Frac flowback and the freshwater impoundment contained fluids and both had more than the required two feet of lined freeboard. Brine tanks were installed, and appeared to be in sound condition. Brine tank diking was installed. Site and access road erosion controls had been implemented and maintained properly.
2198183 Primary Facility 2013-08-22 Routine/Complete Inspection No Violations Noted operating ID
2230446 Primary Facility 2013-12-09 Routine/Complete Inspection No Violations Noted Well appeared to be equipped for production. Brine tank located onsite and it appeared to be in sound condition. Erosion controls had been properly implemented and maintained. Site had been temporarily stabilized. There was no observed accelerated erosion or sedimentation in relation to the access road or well-site.
2244532 Primary Facility 2014-02-11 Routine/Complete Inspection No Violations Noted Well appeared to be equipped for production. Brine tank located onsite and it appeared to be in sound condition. Site was snow covered.
2293414 Primary Facility 2014-08-05 Routine/Complete Inspection No Violations Noted Well appeared to be equipped for production. Brine tank located onsite and it appeared to be in sound condition. Secondary containment for the brine tank was holding water and the water had no sheen. There was no observed accelerated erosion or sedimentation in relation to the site or access road.
2330934 Primary Facility 2014-12-11 Routine/Complete Inspection No Violations Noted Well appeared to be equipped for production. Brine tank located onsite and it appeared to be in sound condition. Secondary containment for the brine tank was holding water and the water had no sheen. There was no observed accelerated erosion or sedimentation in relation to the site or access road.
2359975 Primary Facility 2015-04-08 Routine/Complete Inspection No Violations Noted There was no observed accelerated erosion or sedimentation in relation to the site or access road. Brine tank located onsite and it appeared to be in sound condition.
2444305 Primary Facility 2016-01-28 Routine/Complete Inspection No Violations Noted There was no observed accelerated erosion or sedimentation in relation to the site or access road. Brine tank located onsite and it appeared to be in sound condition. Well appeared to be equipped for production.
2506407 Primary Facility 2016-08-01 Routine/Complete Inspection No Violations Noted There was no observed accelerated erosion or sedimentation in relation to the site or access road. Brine tank located onsite, within secondary containment and it appeared to be in sound condition. Well appeared to be equipped for production.
2556655 Primary Facility 2017-01-30 Routine/Complete Inspection No Violations Noted Well tagged-in production. Well head casing-production set equipment-tank battery-dike containment looked ok.
2589778 Primary Facility 2017-05-03 Routine/Complete Inspection No Violations Noted All site and access road erosion controls had been properly implemented and maintained as outlined in the ESCGP. There was no observed accelerated erosion or sedimentation in relation to the site or access road. Site had been effectively stabilized with vegetative cover. Waste fluid storage tanks located onsite within secondary containment. Both the tanks and containment appeared to be in sound condition.
2673236 Primary Facility 2017-12-20 Routine/Complete Inspection No Violations Noted At time of inspection, well 1H drilled and appears equipped for production. Wells 2H, 3H, and 5H also drilled and appear equipped for production.
2798966 Primary Facility 2018-11-05 Routine/Complete Inspection No Violations Noted Well appears equipped for production. Well head surrounded by cement barriers. Three brine tanks located in secondary containment on site. One brine tank not located in secondary containment, on site.
2836788 Primary Facility 2019-02-05 Routine/Partial Inspection No Violations Noted At the time of inspection, well was producing. Well integrity appeared to be in good condition, with no signs of any leaks. There was some minor rust. The cellar was filled with gravel. The pressure reading for the tubing was reading 295 psi and casing was 450 psi. The well was being injected with a foamer combo. The well was properly labeled and the Emergency Response sign was posted at the site entrance. There were 4 tanks on the pad. 3 were contained within a lined, steel dike and 1 was not contained. 3 line heaters were in use, 1 being a dual heater.

For data sources see[8]