If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-005-30952 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.892111,"lon":-79.418181,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Armstrong | |
Municipality: Boggs Township | |
Operator Name: SNYDER BROS INC | |
Well Pad ID: 146805 | |
Farm/Lease Name: HAROLD P MATEER 1M-45.5 | |
License Status: | |
Spud Date: | |
Permit Date: 2011-12-09 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Vertical Well | |
Conservation: Yes | |
Latitude: 40.892111 | |
Longitude: -79.418181 |
Date | Event |
---|---|
2011-12-09 | New Permit Application |
2012-07-12 | Performed Spud Operation |
2012-07-25 | Drilling Completion |
2012-08-02 | Perforation |
2013-06-11 | NEWLY DRILLED |
For data sources see[4]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2012-08-03 | 2012-08-03 | 7,012 | 159,914 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | ACID INHIBITOR 2 | Superior Well Services | Acid Corrosion Inhibitor | Propargyl alcohol | 107-19-7 | 30.00 | 0.02 | |
PROPRIETARY | 7.00 | 0.00541000 | ||||||
Isopropanol | 67-63-0 | 30.00 | 0.02 | |||||
2-Butoxyethanol | 111-76-2 | 30.00 | 0.02 | |||||
ICP-1000 | Superior Well Services | Iron Control Additive | ANIONIC COPOLYMER | 50.00 | 0.38 | |||
1,2-Propylene glycol | 57-55-6 | 50.00 | 0.38 | |||||
CLAY TREAT LT | Superior Well Services | Clay Control | Choline chloride | 67-48-1 | 80.00 | 0.04 | ||
Super 100NE | Superior Well Services | Surfactant/Foamer | Isopropanol | 67-63-0 | 30.00 | 3.45 | ||
2-Butoxyethanol | 111-76-2 | 7.00 | 0.80 | |||||
SUPER TSC | Superior Well Services | Paraffin & Scale Additive | 1,2,4-Butanetricarboxylic acid, 2-phosphono- | 37971-36-1 | 10.00 | 0.03 | ||
1,2-Propylene glycol | 57-55-6 | 50.00 | 0.19 | |||||
ANIONIC POLYMER | 10.00 | 0.03 | ||||||
ANIONIC COPOLYMER | 10.00 | 0.03 | ||||||
SUPER TSC | Superior Well Services | Scale Control | ||||||
KR-153SL | Superior Well Services | Biocide | Diethylene glycol | 111-46-6 | 3.50 | 0.01 | ||
Ethylene glycol | 107-21-1 | 1.00 | 0.00386000 | |||||
2,2-Dibromo-3-nitrilopropionamide | 10222-01-2 | 20.00 | 0.07 | |||||
Polyethylene glycol | 25322-68-3 | 50.00 | 0.19 | |||||
Hydrochloric Acid | Superior Well Services | Cement/Formation Breakdown | Water | 7732-18-5 | 92.50 | 23.82 | ||
Hydrochloric acid | 7647-01-0 | 7.50 | 1.93 | |||||
NO FOAM | Superior Well Services | Antifoam | Distillates, petroleum, hydrotreated heavy paraffinic | 64742-54-7 | 0.00 | 0.00 | ||
WFR-3B | Superior Well Services | Friction Reducer | Distillates, petroleum, hydrotreated light | 64742-47-8 | 30.00 | 3.02 | ||
Stoddard solvent | 8052-41-3 | 10.00 | 1.00 | |||||
Ethoxylated C12-16 alcohols | 68551-12-2 | 4.00 | 0.40 | |||||
1,2-Propylene glycol | 57-55-6 | 25.00 | 2.52 |
For data sources see[5]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2011 | SNYDER BROS INC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2012 | SNYDER BROS INC | 44,107.00 | 112 | 0.00 | 0 | 0.00 | 0 |
2013 | SNYDER BROS INC | 70,087.00 | 351 | 0.00 | 0 | 0.00 | 0 |
2014 | SNYDER BROS INC | 39,384.00 | 362 | 0.00 | 0 | 0.00 | 0 |
2015 | SNYDER BROS INC | 28,788.00 | 358 | 0.00 | 0 | 0.00 | 0 |
2016 | SNYDER BROS INC | 24,990.00 | 352 | 0.00 | 0 | 0.00 | 0 |
2017 | SNYDER BROS INC | 21,351.00 | 358 | 0.00 | 0 | 0.00 | 0 |
2018 | SNYDER BROS INC | 20,906.00 | 357 | 0.00 | 0 | 0.00 | 0 |
2019 | SNYDER BROS INC | 19,001.00 | 357 | 0.00 | 0 | 0.00 | 0 |
For data sources see[6]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2012 | SNYDER BROS INC | Fracing Fluid Waste | 440.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0254185 |
2012 | SNYDER BROS INC | Drill Cuttings | 118.00 Tons | ON SITE ENCAPSULATION | |
2012 | SNYDER BROS INC | Fracing Fluid Waste | 330.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2012 | SNYDER BROS INC | Fracing Fluid Waste | 175.00 Bbl | INJECTION DISPOSAL WELL | 34-155-23795 |
2012 | SNYDER BROS INC | Fracing Fluid Waste | 935.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | EPA ID: 748-163 |
2012 | SNYDER BROS INC | Fracing Fluid Waste | 180.00 Bbl | INJECTION DISPOSAL WELL | 34-133-20525 |
2012 | SNYDER BROS INC | Produced Fluid | 80.00 Bbl | INJECTION DISPOSAL WELL | 34-155-21893 |
2013 | SNYDER BROS INC | Produced Fluid | 97.00 Bbl | INJECTION DISPOSAL WELL | 34-155-21438 |
2013 | SNYDER BROS INC | Produced Fluid | 175.00 Bbl | INJECTION DISPOSAL WELL | 34-155-23732 |
2015 | SNYDER BROS INC | Produced Fluid | 95.00 Bbl | INJECTION DISPOSAL WELL | 34-155-23196 |
2016 | SNYDER BROS INC | Produced Fluid | 105.00 Bbl | INJECTION DISPOSAL WELL | 34-155-23196 |
2018 | SNYDER BROS INC | Produced Fluid | 134.00 Bbl | INJECTION DISPOSAL WELL | 34-099-23158 |
For data sources see[7]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2079748 | Primary Facility | 2012-06-25 | Routine/Complete Inspection | No Violations Noted | Site preparation was in its final stages at the time of the inspection. Site construction and E&S control implementation had been performed in accordance with the E&S plan located onsite. The E&S controls implemented should effectively minimize accelerated erosion and sedimentation provided they are properly maintained. Seeding and mulching pertaining to temporary stabilization should be completed by 06/27/12 according to operator reprsentative Melanie Peligreneli. |
2082448 | Primary Facility | 2012-07-11 | Routine/Complete Inspection | No Violations Noted | Site preperation was completed, drilling equipment is to be moved onsite 07/11/12 and 07/12/12. Drill pit located onsite. Pit liner appeared to be in sound condition. Site and access road erosion controls had been properly implemented and maintained. There was no observed accelerated erosion or sedimentation observed in relation to either the access road or well-site. |
2083763 | Primary Facility | 2012-07-12 | Drilling/Alteration | No Violations Noted | Equipment on site: no personnel |
2083776 | Primary Facility | 2012-07-13 | Drilling/Alteration | No Violations Noted | Penetrated open mine @ 226'. |
2101349 | Primary Facility | 2012-09-19 | Routine/Complete Inspection | No Violations Noted | Drilling had been completed, well appeared to be equipped for production. Brine tanks located onsite and they appeared to be in sound condition. Site had been properly restored and the vegetation had begun to take hold and it met the 70% uniform coverage. |
2383145 | Primary Facility | 2015-06-29 | Routine/Complete Inspection | No Violations Noted | Well appeared to be equipped for production, brine tanks located onsite and they appeared to be in sound condition. There was no observed accelerated erosion or sedimentation in relation to the site or access road. |
2748382 | Primary Facility | 2018-07-03 | Routine/Complete Inspection | No Violations Noted | This well is tagged and in production. The annulus is open. The well head casing, piping, production set equipment and 2 grounded 100 bbl fiberglass fluid collection tanks look ok. |
For data sources see[8]