If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-005-30969 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.869828,"lon":-79.588119,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Armstrong | |
Municipality: East Franklin Township | |
Operator Name: SNYDER BROS INC | |
Well Pad ID: 146368 | |
Farm/Lease Name: STEVEN H SHAY 1M | |
License Status: | |
Spud Date: | |
Permit Date: 2011-12-13 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Vertical Well | |
Conservation: Yes | |
Latitude: 40.869828 | |
Longitude: -79.588119 |
Date | Event |
---|---|
2011-12-13 | New Permit Application |
2012-01-30 | Performed Spud Operation |
2012-02-08 | Drilling Completion |
2012-05-11 | Perforation |
2012-10-26 | NEWLY DRILLED |
For data sources see[4]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2012-05-15 | 2012-05-15 | 6,616 | 82,311 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | WFR-3B | Superior Well Services | Friction Reducer | Ethoxylated C12-16 alcohols | 68551-12-2 | 4.00 | 0.30 | |
1,2-Propylene glycol | 57-55-6 | 25.00 | 1.89 | |||||
Stoddard solvent | 8052-41-3 | 10.00 | 0.75 | |||||
Distillates, petroleum, hydrotreated light | 64742-47-8 | 30.00 | 2.27 | |||||
KR-153SL | Superior Well Services | Biocide | Ethylene glycol | 107-21-1 | 1.00 | 0.00356000 | ||
Polyethylene glycol | 25322-68-3 | 50.00 | 0.17 | |||||
2,2-Dibromo-3-nitrilopropionamide | 10222-01-2 | 20.00 | 0.07 | |||||
Diethylene glycol | 111-46-6 | 3.50 | 0.01 | |||||
Super 100NE | Superior Well Services | Surfactant/Foamer | Isopropanol | 67-63-0 | 30.00 | 3.13 | ||
2-Butoxyethanol | 111-76-2 | 7.00 | 0.73 | |||||
SUPER TSC | Superior Well Services | Scale Control | ||||||
SUPER TSC | Superior Well Services | Paraffin & Scale Additive | 1,2,4-Butanetricarboxylic acid, 2-phosphono- | 37971-36-1 | 10.00 | 0.03 | ||
ANIONIC POLYMER | 10.00 | 0.03 | ||||||
1,2-Propylene glycol | 57-55-6 | 50.00 | 0.17 | |||||
ANIONIC COPOLYMER | 10.00 | 0.03 | ||||||
Hydrochloric Acid | Superior Well Services | Cement/Formation Breakdown | Water | 7732-18-5 | 92.50 | 20.59 | ||
Hydrochloric acid | 7647-01-0 | 7.50 | 1.67 | |||||
ICP-1000 | Superior Well Services | Iron Control Additive | ANIONIC COPOLYMER | 50.00 | 0.31 | |||
1,2-Propylene glycol | 57-55-6 | 50.00 | 0.31 |
For data sources see[5]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2011 | SNYDER BROS INC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2012 | SNYDER BROS INC | 44,009.00 | 362 | 0.00 | 0 | 0.00 | 0 |
2013 | SNYDER BROS INC | 36,938.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2014 | SNYDER BROS INC | 25,579.00 | 363 | 0.00 | 0 | 0.00 | 0 |
2015 | SNYDER BROS INC | 18,514.00 | 357 | 0.00 | 0 | 0.00 | 0 |
2016 | SNYDER BROS INC | 15,845.00 | 350 | 0.00 | 0 | 0.00 | 0 |
2017 | SNYDER BROS INC | 12,236.00 | 357 | 0.00 | 0 | 0.00 | 0 |
2018 | SNYDER BROS INC | 9,791.00 | 346 | 0.00 | 0 | 0.00 | 0 |
2019 | SNYDER BROS INC | 7,635.00 | 338 | 0.00 | 0 | 0.00 | 0 |
For data sources see[6]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2012 | SNYDER BROS INC | Produced Fluid | 80.00 Bbl | INJECTION DISPOSAL WELL | 34-155-21893 |
2012 | SNYDER BROS INC | Produced Fluid | 160.00 Bbl | INJECTION DISPOSAL WELL | 34-155-23584 |
2012 | SNYDER BROS INC | Fracing Fluid Waste | 1,080.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123SW008 |
2012 | SNYDER BROS INC | Drill Cuttings | 109.00 Tons | ON SITE ENCAPSULATION | |
2012 | SNYDER BROS INC | Produced Fluid | 80.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123SW008 |
2014 | SNYDER BROS INC | Produced Fluid | 95.00 Bbl | INJECTION DISPOSAL WELL | 34-155-23732 |
2017 | SNYDER BROS INC | 95.00 Bbl | INJECTION DISPOSAL WELL | 34-155-23196 | |
2017 | SNYDER BROS INC | Produced Fluid | 95.00 Bbl | INJECTION DISPOSAL WELL | 34-155-23196 |
For data sources see[7]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2038489 | Primary Facility | 2012-01-31 | Routine/Complete Inspection | No Violations Noted | Drilling was ongoing at the time of the inspection. Drill pit located onsite. Pit contained minimal drill cuttings and fluids. Pit had more than the required two feet of lined freeboard. E&S plan had been implemented properly and there was no evidence observed of accelerated erosion or sedimentation. |
2067675 | Primary Facility | 2012-05-14 | Routine/Complete Inspection | No Violations Noted | At the time of inspection the well appears to be drilled and Superior Well Services was onsite beginning the stimulation process. The Department notes that at the time of inspection the drill pit located onsite appears to be in sound condition with the required amount of freeboard. At the time of inspection the E&S plan was onsite and appears to properly implemented and maintained. No accelerated erosion observed in relation to the access road or well pad area. |
2073115 | Primary Facility | 2012-05-23 | Drilling/Alteration | No Violations Noted | Well in production post frac at time of inspection. Pit lined and freeboard maintained. |
2104453 | Primary Facility | 2012-10-02 | Site Restoration | No Violations Noted | At the time of inspection the well appears to be drilled and equipped for production. The well apparatus and brine tanks located onsite appear to be in sound condition. No observation of accelerated erosion or sedimentation in relation to the well pad or access road. The site appears to meet the 70% uniform vegetative coverage criteria for restoration. The site is restored. The Department notes that the well tag is illegible at the time of inspection. The Department suggests the Operator install a legible well tag at their easiest convenience. |
2339612 | Primary Facility | 2015-01-29 | Routine/Complete Inspection | No Violations Noted | Well appeared to be equipped for production. Brine tanks located onsite and they appeared to be in sound condition. There was no observed accelerated erosion or sedimentation in relation to the site or access road. |
2697491 | Primary Facility | 2018-02-23 | Routine/Complete Inspection | No Violations Noted | This well is tagged and in production. The annulus is open. The well head casing, production set equipment, piping and two grounded 100 bbl fluid collection tanks look ok. |
2790229 | Primary Facility | 2018-10-17 | Routine/Complete Inspection | No Violations Noted | This well is tagged and in production. The annulus is open. The well head casing, piping, production set equipment and two grounded 100 bbl fiberglass fluid collection tanks look ok. |
For data sources see[8]