If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-005-30998 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.889747,"lon":-79.613631,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Armstrong | |
Municipality: West Franklin Township | |
Operator Name: SNYDER BROS INC | |
Well Pad ID: 147431 | |
Farm/Lease Name: MO MINTEER FARMS LP 1M-1603 | |
License Status: | |
Spud Date: | |
Permit Date: 2012-02-14 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Vertical Well | |
Conservation: Yes | |
Latitude: 40.889747 | |
Longitude: -79.613631 |
Date | Event |
---|---|
2012-02-14 | New Permit Application |
2012-08-28 | Performed Spud Operation |
2012-09-07 | Drilling Completion |
2012-11-12 | Perforation |
2013-04-25 | NEWLY DRILLED |
For data sources see[4]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2012-11-13 | 2012-11-13 | 6,638 | 164,629 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | WFR-3B | Nabors Industries | Friction Reducer | 1,2-Propylene glycol | 57-55-6 | 25.00 | 0.01 | |
Ethoxylated C12-16 alcohols | 68551-12-2 | 4.00 | 0.00272770 | |||||
Distillates, petroleum, hydrotreated light | 64742-47-8 | 30.00 | 0.02 | |||||
Stoddard solvent | 8052-41-3 | 10.00 | 0.00681930 | |||||
SUPER TSC | Nabors Industries | Paraffin & Scale Additive | 1,2,4-Butanetricarboxylic acid, 2-phosphono- | 37971-36-1 | 10.00 | 0.00034670 | ||
ANIONIC COPOLYMER | 10.00 | 0.00034670 | ||||||
1,2-Propylene glycol | 57-55-6 | 50.00 | 0.00173370 | |||||
SUPER MAX | Nabors Industries | Surfactant/Foamer | 2-Ethylhexanol | 104-76-7 | 40.00 | 0.03 | ||
Isopropanol | 67-63-0 | 30.00 | 0.02 | |||||
2-Butoxyethanol | 111-76-2 | 7.00 | 0.00574440 | |||||
PROPRIETARY | 7.00 | 0.00574440 | ||||||
CLAY TREAT LT | Nabors Industries | Clay Control | Choline chloride | 67-48-1 | 80.00 | 0.00036990 | ||
SUPER TSC | Nabors Industries | Scale Control | ANIONIC POLYMER | 10.00 | 0.00034670 | |||
Hydrochloric Acid | Nabors Industries | Cement/Formation Breakdown | Water | 7732-18-5 | 92.50 | 0.21 | ||
Hydrochloric acid | 7647-01-0 | 7.50 | 0.01 | |||||
ICP-1000 | Nabors Industries | Iron Control Additive | 1,2-Propylene glycol | 57-55-6 | 50.00 | 0.00346750 | ||
ANIONIC COPOLYMER | 50.00 | 0.00346750 | ||||||
ACID INHIBITOR 2 | Nabors Industries | Acid Corrosion Inhibitor | PROPRIETARY | 0.00004850 | ||||
2-Butoxyethanol | 111-76-2 | 0.00020800 | ||||||
Isopropanol | 67-63-0 | 0.00020800 | ||||||
Propargyl alcohol | 107-19-7 | 0.00020800 | ||||||
KR-153SL | Nabors Industries | Biocide | Diethylene glycol | 111-46-6 | 3.50 | 0.00012140 | ||
2,2-Dibromo-3-nitrilopropionamide | 10222-01-2 | 20.00 | 0.00069350 | |||||
Ethylene glycol | 107-21-1 | 1.00 | 0.00003470 | |||||
Polyethylene glycol | 25322-68-3 | 50.00 | 0.00173370 |
For data sources see[5]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2012 | SNYDER BROS INC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2013 | SNYDER BROS INC | 67,322.00 | 363 | 0.00 | 0 | 0.00 | 0 |
2014 | SNYDER BROS INC | 27,476.00 | 355 | 0.00 | 0 | 0.00 | 0 |
2015 | SNYDER BROS INC | 18,907.00 | 354 | 0.00 | 0 | 0.00 | 0 |
2016 | SNYDER BROS INC | 13,116.00 | 339 | 0.00 | 0 | 0.00 | 0 |
2017 | SNYDER BROS INC | 13,603.00 | 352 | 0.00 | 0 | 0.00 | 0 |
2018 | SNYDER BROS INC | 13,696.00 | 356 | 0.00 | 0 | 0.00 | 0 |
2019 | SNYDER BROS INC | 13,396.00 | 363 | 0.00 | 0 | 0.00 | 0 |
For data sources see[6]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2012 | SNYDER BROS INC | Fracing Fluid Waste | 220.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0254185 |
2012 | SNYDER BROS INC | Drill Cuttings | 110.00 Tons | ON SITE ENCAPSULATION | |
2012 | SNYDER BROS INC | Produced Fluid | 240.00 Bbl | INJECTION DISPOSAL WELL | 34-155-21438 |
2012 | SNYDER BROS INC | Produced Fluid | 90.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | EPA ID: 748-163 |
2012 | SNYDER BROS INC | Fracing Fluid Waste | 1,410.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NW006 |
2012 | SNYDER BROS INC | Fracing Fluid Waste | 630.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | EPA ID: 748-163 |
2012 | SNYDER BROS INC | Produced Fluid | 80.00 Bbl | INJECTION DISPOSAL WELL | 34-155-21893 |
2012 | SNYDER BROS INC | Produced Fluid | 160.00 Bbl | INJECTION DISPOSAL WELL | 34-155-23795 |
2013 | SNYDER BROS INC | Produced Fluid | 94.00 Bbl | INJECTION DISPOSAL WELL | 34-155-23223 |
2013 | SNYDER BROS INC | Produced Fluid | 175.00 Bbl | INJECTION DISPOSAL WELL | 34-155-21438 |
2013 | SNYDER BROS INC | Produced Fluid | 429.00 Bbl | INJECTION DISPOSAL WELL | 34-155-23732 |
2014 | SNYDER BROS INC | Produced Fluid | 93.00 Bbl | INJECTION DISPOSAL WELL | 34-155-23732 |
2014 | SNYDER BROS INC | Produced Fluid | 120.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NW009 |
2014 | SNYDER BROS INC | Produced Fluid | 110.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123SW005 |
2015 | SNYDER BROS INC | Produced Fluid | 95.00 Bbl | INJECTION DISPOSAL WELL | 34-155-23196 |
2016 | SNYDER BROS INC | Produced Fluid | 95.00 Bbl | INJECTION DISPOSAL WELL | 34-155-23223 |
2018 | SNYDER BROS INC | Produced Fluid | 95.00 Bbl | INJECTION DISPOSAL WELL | 34-099-23158 |
For data sources see[7]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2089679 | Primary Facility | 2012-08-07 | Routine/Complete Inspection | No Violations Noted | Pre-operation inspection as requested by the Operator. At the time of inspection the erosion and sedimentation control plan was onsite and properly implemented and maintained. No observation of accelerated erosion and sedimentation in relation to the access road or well pad area. All BMP's appear to be in sound condition and installed properly. The drill pit located onsite appeared to be in sound condition and had the required 2' of freeboard. The Department also suggests the Operator continue to monitor the site weekly and after significant precipitation events to ensure erosion and sedimentation is kept at a minimum. |
2111187 | Primary Facility | 2012-10-24 | Routine/Complete Inspection | No Violations Noted | At the time of inspection the well appeared drilled but not stimulated or equipped for production. At the time of inspection the erosion and sedimentation control plan was onsite and properly implemented and maintained. No observation of accelerated erosion and sedimentation in relation to the access road or well pad area. All BMP's appear to be in sound condition and installed properly. The drill pit located onsite appeared to be in sound condition and had the required 2' of freeboard. The Department also suggests the Operator continue to monitor the site weekly and after significant precipitation events to ensure erosion and sedimentation is kept at a minimum. |
2134699 | Primary Facility | 2013-01-30 | Routine/Complete Inspection | No Violations Noted | Well operating and properly identified. |
2173566 | Primary Facility | 2013-06-07 | Routine/Complete Inspection | No Violations Noted | Well appeared to be equipped for production. Brine tanks located on-site and they appeared to be in sound condition. Site had been properly restored and the vegetation had begun to emerge. There was no evidence observed of accelerated erosion or sedimentation in relation to the site or access road. The operator should continue to monitor the site to insure that 70% uniform vegetative cover is met |
2185979 | Primary Facility | 2013-07-19 | Site Restoration | No Violations Noted | Well appeared to be equipped for production. Brine tanks located on-site and they appeared to be in sound condition. Site had been properly restored and the vegetation met the 70% uniform coverage criteria. There was no evidence observed of accelerated erosion or sedimentation in relation to the site or access road. |
2487292 | Primary Facility | 2016-05-25 | Routine/Complete Inspection | No Violations Noted | Well appeared to be equipped for production. Brine tanks located onsite and they appeared to be in sound condition. There was no observed accelerated erosion or sedimentation in relation to the site or access road. It was noted that the well pad area had been used as logging and sawmill area. The well pad area had been disturbed as a result of this activity. |
2589503 | Primary Facility | 2017-05-02 | Routine/Complete Inspection | No Violations Noted | Well tagged-on-annulus open. Well head casing-production set equipment-2 grounded 100 bbl fiberglass tanks looked ok. |
For data sources see[8]