If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-005-31018 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.861092,"lon":-79.593592,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Armstrong | |
Municipality: East Franklin Township | |
Operator Name: SNYDER BROS INC | |
Well Pad ID: 146257 | |
Farm/Lease Name: SAGC 3M-172 | |
License Status: | |
Spud Date: | |
Permit Date: 2012-03-14 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Vertical Well | |
Conservation: Yes | |
Latitude: 40.861092 | |
Longitude: -79.593592 |
Date | Event |
---|---|
2012-03-14 | New Permit Application |
2012-08-16 | Performed Spud Operation |
2012-08-28 | Drilling Completion |
2012-09-06 | Perforation |
2013-07-11 | NEWLY DRILLED |
For data sources see[4]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2012-09-06 | 2012-09-06 | 6,638 | 158,123 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | WFR-3B | Superior Well Services | Friction Reducer | Distillates, petroleum, hydrotreated light | 64742-47-8 | 30.00 | 0.02 | |
Ethoxylated C12-16 alcohols | 68551-12-2 | 4.00 | 0.00299000 | |||||
1,2-Propylene glycol | 57-55-6 | 25.00 | 0.01 | |||||
Stoddard solvent | 8052-41-3 | 10.00 | 0.00747510 | |||||
ACID INHIBITOR 2 | Superior Well Services | Acid Corrosion Inhibitor | 2-Butoxyethanol | 111-76-2 | 0.00021160 | |||
Isopropanol | 67-63-0 | 0.00021160 | ||||||
Propargyl alcohol | 107-19-7 | 0.00021160 | ||||||
PROPRIETARY | 0.00004940 | |||||||
ICP-1000 | Superior Well Services | Iron Control Additive | ANIONIC COPOLYMER | 50.00 | 0.00352600 | |||
1,2-Propylene glycol | 57-55-6 | 50.00 | 0.00352600 | |||||
NO FOAM | Superior Well Services | Antifoam | Distillates, petroleum, hydrotreated heavy paraffinic | 64742-54-7 | 0.00050000 | 0.00000000 | ||
Hydrochloric Acid | Superior Well Services | Cement/Formation Breakdown | Water | 7732-18-5 | 92.50 | 0.21 | ||
Hydrochloric acid | 7647-01-0 | 7.50 | 0.01 | |||||
SUPER TSC | Superior Well Services | Scale Control | ANIONIC COPOLYMER | 10.00 | 0.00035260 | |||
ANIONIC POLYMER | 10.00 | 0.00035260 | ||||||
1,2,4-Butanetricarboxylic acid, 2-phosphono- | 37971-36-1 | 10.00 | 0.00035260 | |||||
1,2-Propylene glycol | 57-55-6 | 50.00 | 0.00176300 | |||||
Super 100NE | Superior Well Services | Surfactant/Foamer | 2-Butoxyethanol | 111-76-2 | 7.00 | 0.00751970 | ||
Isopropanol | 67-63-0 | 30.00 | 0.03 | |||||
CLAY TREAT LT | Superior Well Services | Clay Control | Choline chloride | 67-48-1 | 80.00 | 0.00037610 | ||
SUPER TSC | Superior Well Services | Paraffin & Scale Additive | ||||||
KR-153SL | Superior Well Services | Biocide | 2,2-Dibromo-3-nitrilopropionamide | 10222-01-2 | 20.00 | 0.00070520 | ||
Polyethylene glycol | 25322-68-3 | 50.00 | 0.00176300 | |||||
Ethylene glycol | 107-21-1 | 1.00 | 0.00003530 | |||||
Diethylene glycol | 111-46-6 | 3.50 | 0.00012340 |
For data sources see[5]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2012 | SNYDER BROS INC | 34,761.00 | 76 | 0.00 | 0 | 0.00 | 0 |
2013 | SNYDER BROS INC | 71,653.00 | 362 | 0.00 | 0 | 0.00 | 0 |
2014 | SNYDER BROS INC | 40,833.00 | 363 | 0.00 | 0 | 0.00 | 0 |
2015 | SNYDER BROS INC | 27,547.00 | 355 | 0.00 | 0 | 0.00 | 0 |
2016 | SNYDER BROS INC | 22,762.00 | 357 | 0.00 | 0 | 0.00 | 0 |
2017 | SNYDER BROS INC | 19,889.00 | 355 | 0.00 | 0 | 0.00 | 0 |
2018 | SNYDER BROS INC | 16,375.00 | 352 | 0.00 | 0 | 0.00 | 0 |
2019 | SNYDER BROS INC | 14,578.00 | 358 | 0.00 | 0 | 0.00 | 0 |
For data sources see[6]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2012 | SNYDER BROS INC | Fracing Fluid Waste | 2,340.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | EPA ID: 748-163 |
2012 | SNYDER BROS INC | Produced Fluid | 163.00 Bbl | INJECTION DISPOSAL WELL | 34-155-21893 |
2012 | SNYDER BROS INC | Fracing Fluid Waste | 1,800.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2012 | SNYDER BROS INC | Produced Fluid | 80.00 Bbl | INJECTION DISPOSAL WELL | 34-155-23795 |
2012 | SNYDER BROS INC | Fracing Fluid Waste | 330.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0254185 |
2012 | SNYDER BROS INC | Drill Cuttings | 112.00 Tons | ON SITE ENCAPSULATION | |
2012 | SNYDER BROS INC | Produced Fluid | 492.00 Bbl | INJECTION DISPOSAL WELL | 34-155-21438 |
2012 | SNYDER BROS INC | Fracing Fluid Waste | 770.00 Bbl | STORAGE PENDING DISPOSAL OR REUSE | |
2013 | SNYDER BROS INC | Produced Fluid | 80.00 Bbl | INJECTION DISPOSAL WELL | 34-155-23223 |
2013 | SNYDER BROS INC | Produced Fluid | 80.00 Bbl | INJECTION DISPOSAL WELL | 34-155-21438 |
2013 | SNYDER BROS INC | Produced Fluid | 130.00 Bbl | INJECTION DISPOSAL WELL | 34-155-21893 |
2014 | SNYDER BROS INC | Produced Fluid | 93.00 Bbl | INJECTION DISPOSAL WELL | 34-155-23223 |
2015 | SNYDER BROS INC | Produced Fluid | 95.00 Bbl | INJECTION DISPOSAL WELL | 34-155-23732 |
2016 | SNYDER BROS INC | Produced Fluid | 95.00 Bbl | INJECTION DISPOSAL WELL | 34-155-23196 |
2017 | SNYDER BROS INC | Produced Fluid | 95.00 Bbl | INJECTION DISPOSAL WELL | 34-155-23223 |
2017 | SNYDER BROS INC | 95.00 Bbl | INJECTION DISPOSAL WELL | 34-155-23223 | |
2019 | SNYDER BROS INC | Produced Fluid | 90.00 Bbl | INJECTION DISPOSAL WELL | 34-099-23158 |
For data sources see[7]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2089681 | Primary Facility | 2012-08-07 | Routine/Complete Inspection | No Violations Noted | Pre-operation inspection as requested by the Operator. At the time of inspection the erosion and sedimentation control plan was on site. The site was built according to plan and all BMPs appeared to be properly installed and maintained. The drill pit located onsite appeared to be in sound condition and had the required 2' of freeboard. The Department also suggests the Operator continue to monitor the site weekly and after significant precipitation events to ensure erosion and sedimentation is kept at a minimum. |
2110440 | Primary Facility | 2012-10-24 | Routine/Complete Inspection | No Violations Noted | Well operating and properly identified. |
2111182 | Primary Facility | 2012-10-24 | Routine/Complete Inspection | No Violations Noted | At the time of inspection the site appeared to be drilled and equipped for production. The associated well apparatus and brine tanks appeared to be in very good condition. The Department notes that the operator has re-graded, seeded and mulched the disturbed area, but does not yet have 70% vegetative cover. Department also suggests the Operator continue to monitor the site weekly and after significant precipitation events to ensure erosion and sedimentation is kept at a minimum. |
2173554 | Primary Facility | 2013-06-07 | Site Restoration | No Violations Noted | Well appeared to be equipped for production. Brine tanks located on-site and they appeared to be in sound condition. Site had been properly regraded, seeded, mulched and the vegetation had begun to take hold. It was noted at the time of the inspection that the majority of the site had been disturbed so that the surrounding field could be utilized for agricultural crop development. Due to this the collection ditch located at the bottom of the slope adjacent to the well equipment should be stabilized with durable rock so as to minimize the amount of sediment generated and transported to or across the cultivated field. |
2442028 | Primary Facility | 2016-01-20 | Routine/Complete Inspection | No Violations Noted | Well tagged-in production. Annulus open. Well head casing-production equipment-meter set-2-100 bbl tanks all looked ok. |
2482695 | Primary Facility | 2016-05-10 | Routine/Complete Inspection | No Violations Noted | Well appeared to be equipped for production. Brine tanks located onsite and they appeared to be in sound condition. There was no observed accelerated erosion or sedimentation in relation to the site or access road. It was noted that well was located amidst agricultural fields. |
For data sources see[8]