Well Details

Well ID: 37-005-31024
Loading map...
Country: United States
State: Pennsylvania
County: Armstrong
Municipality: Gilpin Township
Operator Name: MDS ENERGY DEV LLC
Well Pad ID: 146493
Farm/Lease Name: RALPH MYERS ETUX 2M-28
License Status:
Spud Date:
Permit Date: 2012-03-30
Well Type: GAS
Unconventional Well: Y
Configuration: Vertical Well
Conservation: Yes
Latitude: 40.680822
Longitude: -79.575833

For data sources see[1][2][3]

Well History

Date Event
2012-03-30 New Permit Application
2012-03-30 Performed Spud Operation
2012-05-23 Drilling Completion
2012-12-19 Perforation
2013-05-29 NEWLY DRILLED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2012-12-19 2012-12-19 7,252 162,033

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Supermax Surfactant/Foamer Isopropanol 67-63-0 30.00 0.00848000
Proprietary 7.00 0.00198000
2-Butoxyethanol 111-76-2 7.00 0.00198000
2-Ethylhexanol 104-76-7 40.00 0.01
Acid Inhibitor-2 Acid Corrosion Inhibitor Proprietary 7.00 0.00007000
2-Butoxyethanol 111-76-2 30.00 0.00028000
Isopropanol 67-63-0 30.00 0.00028000
Propargyl alcohol 107-19-7 30.00 0.00028000
Nitrogen Stimulant Fluid Nitrogen, liquid 7727-37-9 100.00 28.62
Hydrochloric Acid 0-7.5 Bulk Acid Hydrochloric acid 7647-01-0 7.00 0.01
Acid Inhibitor-2 Nabors Industries Acid Corrosion Inhibitor
Clay Treat Clay Control Choline chloride 67-48-1 80.00 0.00056000
KR-153SL Biocide 2,2-Dibromo-3-nitrilopropionamide 10222-01-2 20.00 0.00116000
Polyethylene glycol 25322-68-3 50.00 0.00291000
Ethylene glycol 107-21-1 1.00 0.00006000
Diethylene glycol 111-46-6 3.50 0.00020000
ICP-1000 Low Freeze Point Dispersant Anionic Copolymer (proprietary) 50.00 0.00557000
1,2-Propylene glycol 57-55-6 50.00 0.00557000
WFR-3B Friction Reducer 1,2-Propylene glycol 57-55-6 25.00 0.02
Distillates, petroleum, hydrotreated light 64742-47-8 30.00 0.03
Ethoxylated C12-16 alcohols 68551-12-2 4.00 0.00415000
Stoddard solvent 8052-41-3 10.00 0.01
Super TSC Scale Control Anionic Copolymer (proprietary)
1,2-Propylene glycol 57-55-6 50.00 0.00264000
1,2,4-Butanetricarboxylic acid, 2-phosphono- 37971-36-1
Hydrochloric Acid 12.5-18 Bulk Acid Hydrochloric acid 7647-01-0 16.00 0.03
Sand Proppant Quartz 14808-60-7 99.90 19.17

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2012 MDS ENERGY LTD 0.00 0 0.00 0 0.00 0
2013 MDS ENERGY LTD 119,750.00 339 0.00 0 0.00 0
2014 MDS ENERGY LTD 49,892.00 344 0.00 0 0.00 0
2015 MDS ENERGY DEV LLC 37,187.00 348 0.00 0 0.00 0
2016 MDS ENERGY DEV LLC 29,446.00 348 0.00 0 0.00 0
2017 MDS ENERGY DEV LLC 27,376.00 365 0.00 0 0.00 0
2018 MDS ENERGY DEV LLC 22,833.00 364 0.00 0 0.00 0
2019 MDS ENERGY DEV LLC 20,171.00 363 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2012 MDS ENERGY LTD Fracing Fluid Waste 1,530.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NW006
2012 MDS ENERGY LTD Drilling Fluid Waste 220.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0254185
2012 MDS ENERGY LTD Drilling Fluid Waste 90.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE EPA ID: 748-163
2012 MDS ENERGY LTD Drilling Fluid Waste 720.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NW006
2013 MDS ENERGY LTD Fracing Fluid Waste 220.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NW006
2013 MDS ENERGY LTD Produced Fluid 80.00 Bbl INJECTION DISPOSAL WELL 34-155-21438
2013 MDS ENERGY LTD Drilling Fluid Waste 85.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NW006
2013 MDS ENERGY LTD Drilling Fluid Waste 230.00 Bbl INJECTION DISPOSAL WELL 34-155-21438
2016 MDS ENERGY DEV LLC Produced Fluid 118.00 Bbl REUSE OTHER THAN ROAD SPREADING

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2046865 Primary Facility 2012-03-01 Routine/Complete Inspection No Violations Noted E&S plan reviewed as part of OG-57 application.
2055837 Primary Facility 2012-04-02 Routine/Complete Inspection No Violations Noted Drilling commenced on 03/31/12, but was not ongoing at the time of the inspection. Site had been constructed as outliend in the approved E&S plan. Spoke with operator representative via phone regarding the addition of rock to the outflow area of the sediment trap implemented at te base of the fill slope. There was no observed accelerated erosion or sedimentation in relation to the access road or well-site.
2063950 Primary Facility 2012-05-01 Routine/Complete Inspection No Violations Noted Inspection performed as a result of a resumption of drilling notice. Drilling had not as of yet re-commenced. Erosion controls had been implemented and maintained properly. There was no accelerated erosion or sedimenation observed in relation to the access road or well-site. Drill pit constructed onsite and it contained minimal fluids attributed to precipitation. Operator should continue to maintain the site and access road until well development activities are completed.
2067208 Primary Facility 2012-05-03 Drilling/Alteration No Violations Noted @680' ; Pit & E&S OK
2067291 Primary Facility 2012-05-08 Drilling/Alteration No Violations Noted Preparing to install Intermediate casing
2093043 Primary Facility 2012-08-20 Routine/Complete Inspection No Violations Noted Drilling appeared to have been completed. Well was not equipped for production. Site had been effectively temporarily stabilized. E&S controls had been properly implemented and maintained. There was no observed accelerated erosion or sedimentation in relation to the access road or well-site.
2103404 Primary Facility 2012-09-28 Routine/Complete Inspection No Violations Noted Drilling appeared to have been completed, well was not equipped for production. Frac impoundment located onsite and it had more than the required two feet of lined freeboard. There was no evidence observed of accelerated erosion or sedimentation related to the access road or well-site. It was noted that the sediment trap implemented at the outlets of the collection ditches required routine maintenance to insure its continued functionality.
2144156 Primary Facility 2013-03-01 Routine/Complete Inspection No Violations Noted Site had been effectively regraded and temporarily stabilized. There was no observed accelerated erosion or sedimentation in relation to the site or access road. It was noted that the sediment trap implemented at the base of the fill slope for the well pad had been left in place. The operator is reminded that they are responsible for continued maitenance of this erosion control. Well appeared to be equipped for production and brine tanks were located onsite. Brine tanks appeared to be in sound condition.
2168109 Primary Facility 2013-05-15 Site Restoration No Violations Noted Site had been effectively regraded and temporarily stabilized. There was no observed accelerated erosion or sedimentation in relation to the site or access road. Well appeared to be equipped for production and brine tanks were located onsite. Brine tanks appeared to be in sound condition. The sediment trap that had been at the base of the well-site had been removed and that area had been regraded. The site had been seeded and mulched and the vegetation was beginning to take hold. The operator should continue to monitor the site for erosion where the sediment trap had been and to insure that 70% uniform vegetative cover had been achieved.
2348563 Primary Facility 2015-03-02 Routine/Complete Inspection No Violations Noted Well appeared to be equipped for production. Brine tanks located onsite and they appeared to be in sound condition. There was no observed accelerated erosion or sedimentation in relation to the site or access road.
2679081 Primary Facility 2018-01-08 Routine/Partial Inspection No Violations Noted At time of inspection, well is drilled and appears equipped for production.
2762543 Primary Facility 2018-08-10 Routine/Complete Inspection No Violations Noted This well is tagged and in production. The well head casing, piping, production set equipment and 2 grounded 100 bbl fiberglass fluid collection tanks look ok.
2836128 Primary Facility 2019-02-04 Routine/Complete Inspection No Violations Noted On 2/4/19 at 1343 hrs., I conducted a routine inspection of MDS Energy Development, LLC's Ralph Myers etux 2M-28 well (API 005-31024) in Gilpin Twp., Armstrong Co. The well pad is restored and permanently stabilized. The well is equipped for production. A site ID sign is present at the entrance to the well pad. I was unable to access the property to determine if a well tag was affixed to the well head due to a locked gate. I will contact he operator at a later date to arrange access to the site. There are no violations noted for this inspection.

For data sources see[8]