If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-005-31027 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.710661,"lon":-79.626203,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Armstrong | |
Municipality: South Buffalo Township | |
Operator Name: SNYDER BROS INC | |
Well Pad ID: 147131 | |
Farm/Lease Name: WILLIAM H RENSHAW | |
License Status: Plugged and Abandoned | |
Spud Date: 2012-09-26 | |
Permit Date: 2012-03-13 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Vertical Well | |
Conservation: Yes | |
Latitude: 40.710661 | |
Longitude: -79.626203 |
Date | Event |
---|---|
2012-03-13 | New Permit Application |
2012-09-25 | Performed Spud Operation |
2012-10-05 | Drilling Completion |
2012-11-19 | Perforation |
2012-11-19 | Performed Stage 1 of Stimulation |
2012-11-20 | Performed Stage 2 of Stimulation |
2013-05-07 | NEWLY DRILLED |
2019-04-18 | Begin Plugging |
2019-04-25 | Finished Plugging |
2019-09-05 | Fully Plugged |
For data sources see[4]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2012-11-19 | 2012-11-19 | 7,046 | 158,047 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | SUPER TSC | Nabors Industries | Paraffin & Scale Additive | |||||
Hydrochloric Acid | Nabors Industries | Cement/Formation Breakdown | Hydrochloric acid | 7647-01-0 | 7.50 | 0.01 | ||
Water | 7732-18-5 | 92.50 | 0.21 | |||||
SUPER MAX | Nabors Industries | Surfactant/Foamer | 2-Butoxyethanol | 111-76-2 | 7.00 | 0.00583680 | ||
2-Ethylhexanol | 104-76-7 | 40.00 | 0.05 | |||||
PROPRIETARY | 7.00 | 0.00986490 | ||||||
Isopropanol | 67-63-0 | 30.00 | 0.04 | |||||
Super 100NE | Nabors Industries | Surfactant/Foamer | Isopropanol | 67-63-0 | 30.00 | 0.00014090 | ||
2-Butoxyethanol | 111-76-2 | 7.00 | 0.00003290 | |||||
SUPER TSC | Nabors Industries | Scale Control | ANIONIC POLYMER | 10.00 | 0.00035230 | |||
ANIONIC COPOLYMER | 10.00 | 0.00035230 | ||||||
1,2,4-Butanetricarboxylic acid, 2-phosphono- | 37971-36-1 | 10.00 | 0.00035230 | |||||
1,2-Propylene glycol | 57-55-6 | 50.00 | 0.00176160 | |||||
ICP-1000 | Nabors Industries | Iron Control Additive | 1,2-Propylene glycol | 57-55-6 | 50.00 | 0.00352320 | ||
ANIONIC COPOLYMER | 50.00 | 0.00352320 | ||||||
CLAY TREAT LT | Nabors Industries | Clay Control | Choline chloride | 67-48-1 | 80.00 | 0.00037580 | ||
ACID INHIBITOR 2 | Nabors Industries | Acid Corrosion Inhibitor | Propargyl alcohol | 107-19-7 | 0.00021140 | |||
PROPRIETARY | 0.00004930 | |||||||
Isopropanol | 67-63-0 | 0.00021140 | ||||||
2-Butoxyethanol | 111-76-2 | 0.00021140 | ||||||
KR-153SL | Nabors Industries | Biocide | Diethylene glycol | 111-46-6 | 3.50 | 0.00012330 | ||
Polyethylene glycol | 25322-68-3 | 50.00 | 0.00176160 | |||||
2,2-Dibromo-3-nitrilopropionamide | 10222-01-2 | 20.00 | 0.00070460 | |||||
Ethylene glycol | 107-21-1 | 1.00 | 0.00003520 | |||||
WFR-3B | Nabors Industries | Friction Reducer | Stoddard solvent | 8052-41-3 | 10.00 | 0.00683500 | ||
Distillates, petroleum, hydrotreated light | 64742-47-8 | 30.00 | 0.02 | |||||
Ethoxylated C12-16 alcohols | 68551-12-2 | 4.00 | 0.00273400 | |||||
1,2-Propylene glycol | 57-55-6 | 25.00 | 0.01 |
For data sources see[5]
Stimulation Date | Phase Number | Chemical Agent | Volume (gal) | Treating Pressure (psi) | Breakdown Pressure (psi) |
---|---|---|---|---|---|
2012-11-19 | 1 | Sand | 158,047 | 5,748 | 4,960 |
2012-11-20 | 2 | Sand | 158,047 | 5,595 | 3,704 |
For data sources see[6]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2012 | SNYDER BROS INC | 4,397.00 | 7 | 0.00 | 0 | 0.00 | 0 |
2013 | SNYDER BROS INC | 79,935.00 | 360 | 0.00 | 0 | 0.00 | 0 |
2014 | SNYDER BROS INC | 36,346.00 | 362 | 0.00 | 0 | 0.00 | 0 |
2015 | SNYDER BROS INC | 24,820.00 | 352 | 0.00 | 0 | 0.00 | 0 |
2016 | SNYDER BROS INC | 20,070.00 | 319 | 0.00 | 0 | 0.00 | 0 |
2017 | SNYDER BROS INC | 16,136.00 | 289 | 0.00 | 0 | 0.00 | 0 |
2018 | SNYDER BROS INC | 11,371.00 | 239 | 0.00 | 0 | 0.00 | 0 |
2019 | SNYDER BROS INC | 7,425.00 | 119 | 0.00 | 0 | 0.00 | 0 |
For data sources see[7]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2012 | SNYDER BROS INC | Drill Cuttings | 119.00 Tons | ON SITE ENCAPSULATION | |
2012 | SNYDER BROS INC | Produced Fluid | 80.00 Bbl | INJECTION DISPOSAL WELL | 34-155-21438 |
2012 | SNYDER BROS INC | Fracing Fluid Waste | 240.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2012 | SNYDER BROS INC | Fracing Fluid Waste | 2,040.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NW006 |
2012 | SNYDER BROS INC | Produced Fluid | 80.00 Bbl | INJECTION DISPOSAL WELL | 34-155-21893 |
2012 | SNYDER BROS INC | Produced Fluid | 80.00 Bbl | INJECTION DISPOSAL WELL | 34-155-23795 |
2013 | SNYDER BROS INC | Produced Fluid | 160.00 Bbl | INJECTION DISPOSAL WELL | 34-155-21438 |
2013 | SNYDER BROS INC | Produced Fluid | 80.00 Bbl | INJECTION DISPOSAL WELL | 34-155-21447 |
2014 | SNYDER BROS INC | Produced Fluid | 105.00 Bbl | INJECTION DISPOSAL WELL | 34-155-21438 |
2017 | SNYDER BROS INC | Produced Fluid | 95.00 Bbl | INJECTION DISPOSAL WELL | 34-155-23196 |
2017 | SNYDER BROS INC | 95.00 Bbl | INJECTION DISPOSAL WELL | 34-155-23196 | |
2018 | SNYDER BROS INC | Produced Fluid | 34.00 Bbl | INJECTION DISPOSAL WELL | 34-099-23158 |
2019 | SNYDER BROS INC | Produced Fluid | 110.00 Bbl | INJECTION DISPOSAL WELL | 34-099-23158 |
For data sources see[8]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2099870 | Primary Facility | 2012-09-13 | Routine/Complete Inspection | No Violations Noted | Pre-operation inspection at the request of the Operator. At the time of inspection the Erosion and Sedimentation plan was onsite and all BMPs appear to implemented and maintained as outline in the E&S plan. The drill pit located onsite appears to be in sound condition with the required 2 feet of freeboard. The Department notes that at the time of inspection an erosion ditch is forming on the fill side of the well pad area and left unchecked could result in sedimentation transported offsite. The Department suggests the Operator clean out the area behind the silt fence and mend the eroded fill side of the well pad. The Department suggest the Operator continue to monitor the site weekly and after significant precipitation events to ensure site stability and BMPs are maintained. |
2104747 | Primary Facility | 2012-10-03 | Routine/Complete Inspection | No Violations Noted | At the time of inspection the Operator was actively drilling the onsite. The Erosion and Sedimentation plan was onsite and all BMPs appear to implemented and maintained as outline in the E&S plan. The drill pit located onsite appears to be in sound condition with the required 2 feet of freeboard. The Department notes that suggestions made during the 9/13 inspection in relation to the erosion ditch and sediment fence maintenance have not been corrected. The Department suggests again that the Operator mend the erosion ditch forming on the corner of the well pad furthest from the cut slope and pull the built up sediment away from the sediment fence. The Department suggests the Operator continue to monitor the site weekly and after significant precipitation events to ensure site stability and BMPs are maintained. |
2111180 | Primary Facility | 2012-10-24 | Routine/Complete Inspection | No Violations Noted | At the time of inspection the site appeared to be drilled but not equipped for production The Erosion and Sedimentation plan was onsite and all BMPs appear to implemented and maintained as outline in the E&S plan. The drill pit located onsite appears to be in sound condition with the required 2 feet of freeboard. The Department notes that suggestions made during the 9/13 and 10/3 inspection in relation to the erosion ditch and sediment fence maintenance have been corrected. The Department notes that the Operator mended the erosion ditch forming on the corner of the well pad furthest from the cut slope and pulled the built up sediment away from the sediment fence. The Department suggests the Operator continue to monitor the site weekly and after significant precipitation events to ensure site stability and BMPs are maintained. |
2118997 | Primary Facility | 2012-11-28 | Drilling/Alteration | No Violations Noted | Well producing in line after recent frac. Pit lined and freeboard maintained. |
2170517 | Primary Facility | 2013-05-24 | Site Restoration | No Violations Noted | Well appeared to be equipped for production, brine tank located onsite. Brine tank appeared to be in sound condition. Site had been regraded, seeded, mulched and the vegetation ahd begun to emerge. The operator should continue to monitor the site to isnure the continued growth of the vegetation. There was no observed accelerated erosion or sedimentation observed in relation to the site or access road. |
2185962 | Primary Facility | 2013-07-19 | Site Restoration | No Violations Noted | Well appeared to be equipped for production, brine tank located onsite. Brine tank appeared to be in sound condition. Site had been regraded, seeded, mulched and the vegetation met the 70% uniform coverage criteria. There was no observed accelerated erosion or sedimentation observed in relation to the site or access road. |
2381108 | Primary Facility | 2015-06-22 | Routine/Complete Inspection | No Violations Noted | Well appeared to be equipped for production, brine tanks located onsite and they appeared to be in sound condition. There was no observed accelerated erosion or sedimentation in relation to the site or access road. |
2750679 | Primary Facility | 2018-07-11 | Routine/Complete Inspection | No Violations Noted | This well is tagged and in production. The annulus is open. The well head casing, piping, production set equipment and two grounded 100 bbl fiberglass fluid collection tanks look ok. |
For data sources see[9]