{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.594178,"lon":-79.412125,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Armstrong | |
Municipality: South Bend Township | |
Operator Name: CHEVRON APPALACHIA LLC | |
Well Pad ID: 147239 | |
Farm/Lease Name: SPRING CHURCH UNIT 1H | |
License Status: Active | |
Spud Date: 2013-12-17 | |
Permit Date: 2012-09-06 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: Yes | |
Latitude: 40.594178 | |
Longitude: -79.412125 |
Date | Event |
---|---|
2012-09-06 | New Permit Application |
2013-09-24 | New Permit Application |
2013-12-14 | Performed Spud Operation |
2014-05-08 | Drilling Completion |
2014-11-11 | Perforation |
2016-06-03 | Deviated |
For data sources see[4]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2014-11-11 | 2014-12-03 | 7,969 | 5,494,340 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | Proppant | Schlumberger | Proppant | Crystalline Silica | 14808-60-7 | 100 | 9.25082 | 0 |
B466 | Schlumberger | Friction Reducer | Distillates (petroleum), hydrotreated light | 64742-47-8 | 30 | 0.00375926 | 0 | |
Ammonium Acetate | 631-61-8 | 6 | 0.00075185 | 0 | ||||
Alcohol Ethoxylates | Proprietary | 5 | 0.00062654 | 0 | ||||
J580 | Schlumberger | Gelling Agent, Water | Carbohydrate Polymer | Proprietary | 100 | 0.00164893 | 0 | |
L058 | Schlumberger | Iron Stabilizer | Sodium erythorbate | 6381-77-7 | 100 | 0.0006662 | 0 | |
J134 | Schlumberger | Gel Breaker | Hemicellulase enzyme | 9012-54-8 | 100 | 0.00003314 | 0 | |
Base Fluid | Chevron | Carrier/Base Fluid | Water (Including Mix Water Supplied by Client) | 7732-18-5 | 100 | 90.5871 | 0 | |
EC6116A | Nalco | Biocide | 2,2-Dibromo-3-nitrilopropionamide | 10222-01-2 | 30 | 0.00076603 | 0 | |
Dibromoacetonitrile | 3252-43-5 | 5 | 0.00012767 | 0 | ||||
Polyethylene Glycol | 25322-68-3 | 60 | 0.00153206 | 0 | ||||
EC6673W | Nalco | Iron Control | Ethylene Glycol | 107-21-1 | 30 | 0.00077021 | 0 | |
EC6486A | Nalco | Scale Inhibitor | Ethylene Glycol | 107-21-1 | 30 | 0.00083301 | 0 | |
A264 | Schlumberger | Corrosion Inhibitor | Methanol | 67-56-1 | 40 | 0.00005178 | 0 | |
Aliphatic alcohols, ethoxylayed #1 | Proprietary | 30 | 0.00003884 | 0 | ||||
Aliphatic acids | Proprietary | 30 | 0.00003884 | 0 | ||||
Prop-2-yn-1-ol | 107-19-7 | 10 | 0.00001295 | 0 | ||||
15% Acid | Schlumberger | Perf Cleanup | Hydrocloric Acid | 7647-01-0 | 15 | 0.0115821 | 0 |
For data sources see[5]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2013 | CHEVRON APPALACHIA LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2014 | CHEVRON APPALACHIA LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2015 | CHEVRON APPALACHIA LLC | 810,942.00 | 274 | 0.00 | 0 | 0.00 | 0 |
2016 | CHEVRON APPALACHIA LLC | 539,051.00 | 366 | 0.00 | 0 | 0.00 | 0 |
2017 | CHEVRON APPALACHIA LLC | 398,022.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2018 | CHEVRON APPALACHIA LLC | 297,595.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2019 | CHEVRON APPALACHIA LLC | 243,894.00 | 365 | 0.00 | 0 | 0.00 | 0 |
For data sources see[6]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2014 | CHEVRON APPALACHIA LLC | Fracing Fluid Waste | 1,052.50 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123SW001 |
2014 | CHEVRON APPALACHIA LLC | Fracing Fluid Waste | 300.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014 | CHEVRON APPALACHIA LLC | Drilling Fluid Waste | 142.50 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123SW001 |
2014 | CHEVRON APPALACHIA LLC | Drilling Fluid Waste | 177.50 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014 | CHEVRON APPALACHIA LLC | Drill Cuttings | 1,136.14 Tons | LANDFILL | 100434 |
2014 | CHEVRON APPALACHIA LLC | Drill Cuttings | 48.94 Tons | LANDFILL | 100172 |
2015 | CHEVRON APPALACHIA LLC | Fracturing Fluid Waste | 37.02 Tons | LANDFILL | 100172 |
2015 | CHEVRON APPALACHIA LLC | Fracing Fluid Waste | 12,037.50 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2015 | CHEVRON APPALACHIA LLC | Fracing Fluid Waste | 3,580.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123SW001 |
2015 | CHEVRON APPALACHIA LLC | Produced Fluid | 16,689.50 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016 | CHEVRON APPALACHIA LLC | Produced Fluid | 3,792.68 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123SW019 |
2016 | CHEVRON APPALACHIA LLC | Produced Fluid | 6,036.02 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2017 | CHEVRON APPALACHIA LLC | Produced Fluid | 16,601.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW001 |
2017 | CHEVRON APPALACHIA LLC | Produced Fluid | 467.00 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2017 | CHEVRON APPALACHIA LLC | Produced Fluid | 1,868.50 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW019 |
2017 | CHEVRON APPALACHIA LLC | 169.50 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 | |
2017 | CHEVRON APPALACHIA LLC | Produced Fluid | 169.50 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2017 | CHEVRON APPALACHIA LLC | 1,813.50 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW019 | |
2017 | CHEVRON APPALACHIA LLC | 16,601.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW001 | |
2017 | CHEVRON APPALACHIA LLC | 778.00 Bbl | REUSE (AT WELL PAD) | ||
2017 | CHEVRON APPALACHIA LLC | Drilling Fluid Waste | 115.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW019 |
2017 | CHEVRON APPALACHIA LLC | Produced Fluid | 784.00 Bbl | REUSE (AT WELL PAD) | |
2018 | CHEVRON APPALACHIA LLC | Produced Fluid | 694.17 Bbl | REUSE (AT WELL PAD) | |
2018 | CHEVRON APPALACHIA LLC | Produced Fluid | 225.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW019 |
2018 | CHEVRON APPALACHIA LLC | Produced Fluid | 2,221.00 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2018 | CHEVRON APPALACHIA LLC | Produced Fluid | 112.50 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2019 | CHEVRON APPALACHIA LLC | Produced Fluid | 2,635.00 Bbl | REUSE (AT WELL PAD) | |
2019 | CHEVRON APPALACHIA LLC | Produced Fluid | 180.00 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA |
For data sources see[7]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2145485 | Primary Facility | 2013-03-05 | Routine/Complete Inspection | No Violations Noted | Site and access road construction was underway at the time of the inspection. Perimeter site erosion controls had been implemented as outlined in the E&S plan contained within the ESCGP. There was no observed evidence of accelerated erosion or sedimentation with the site or access road. |
2231594 | Primary Facility | 2013-12-07 | Drilling/Alteration | No Violations Noted | Not drillied |
2232873 | Primary Facility | 2013-12-27 | Routine/Complete Inspection | No Violations Noted | Drilling had commenced but was not ongoing at the time of the inspection. Site construction had been completed and the site and access road erosion controls had been implemented as outlined in the E&S included within the ESCGP. There was no observed accelerated erosion or sedimentation. |
2234520 | Primary Facility | 2014-01-06 | Drilling/Alteration | No Violations Noted | rigging up |
2235511 | Primary Facility | 2014-01-09 | Drilling/Alteration | No Violations Noted | drlg 20" hole at 408' |
2238454 | Primary Facility | 2014-01-14 | Drilling/Alteration | No Violations Noted | Rig has moved off well; surface/coal casing set |
2263091 | Primary Facility | 2014-04-16 | Drilling/Alteration | No Violations Noted | rigging up |
2263761 | Primary Facility | 2014-04-18 | Drilling/Alteration | No Violations Noted | preparing to test BOP's |
2263819 | Primary Facility | 2014-04-08 | Routine/Complete Inspection | No Violations Noted | placing matting boards/awiting rig to resume drilling |
2265115 | Primary Facility | 2014-04-22 | Drilling/Alteration | No Violations Noted | WOC on Intermediate String 2442'; w/returns |
2265914 | Primary Facility | 2014-04-28 | Incident- Response to Accident or Event | In Compliance with Policy | Met onsite with Chevron Company Man Russell Justice. Drilling was ongoing at the time of the inspection. Site inspection performed as a follow-up to a spill noitification received on Sunday April 27, 2014. Approximately 15 gallons of a drilling additive, Megamul, was spilled during transfer onsite. The affected media was subsequently excavated and properly disposed of. There was no observed accelerated erosion or sedimentation observed in relation to the site or access road. |
2273430 | Primary Facility | 2014-05-13 | Drilling/Alteration | No Violations Noted | TMD 12233'; production casing cemented |
2273433 | Primary Facility | 2014-05-22 | Drilling/Alteration | No Violations Noted | Drilling complete; production casing installed |
2308417 | Primary Facility | 2014-09-30 | Routine/Complete Inspection | No Violations Noted | Drilling was not ongoing at the time of the inspection. Secondary containment construction was underway for the constructed AST's located on the secondary pad adjacent to the primary pad where the well heads are located. All access road and site erosion controls had been implemented and maintained as outlined in the E&S plan contained within the ESCGP. There was no observed accelerated erosion or sedimentation. |
2334513 | Primary Facility | 2015-01-09 | Routine/Complete Inspection | No Violations Noted | Work was ongoing and equipment was onsite to continue equipping the well for production. The were two constructed AST's for fluid containment located on a secondary pad along a shared access road with the well pad. There was no observed accelerated erosion or sedimentation in relation to the well-site. |
2352627 | Primary Facility | 2015-03-16 | Routine/Complete Inspection | No Violations Noted | Drilling and well stimualtion acitivities had been completed. Brine tanks located onsite and they appeared to be in sound conditon. There was no observed accelerated erosion or sedimentation in relation to the site or access road. |
2375540 | Primary Facility | 2015-06-02 | Routine/Complete Inspection | No Violations Noted | Drilling and well stimualtion acitivities had been completed. Brine tanks located onsite and they appeared to be in sound conditon. There was no observed accelerated erosion or sedimentation in relation to the site or access road. |
2433914 | Primary Facility | 2015-12-17 | Routine/Complete Inspection | No Violations Noted | Drilling and well stimualtion acitivities had been completed. Brine tanks located onsite and they appeared to be in sound conditon. There was no observed accelerated erosion or sedimentation in relation to the site or access road. |
2445866 | Primary Facility | 2016-02-02 | Routine/Complete Inspection | No Violations Noted | Well tagged-in production. Well head casing-equipment-production unit-tanks-dike all look ok. |
2489937 | Primary Facility | 2016-06-03 | Routine/Complete Inspection | No Violations Noted | Drilling and well stimualtion acitivities had been completed, well appeared to be equipped for production. Brine tanks located onsite and they appeared to be in sound conditon. There was no observed accelerated erosion or sedimentation in relation to the site or access road. |
2549274 | Primary Facility | 2016-12-29 | Routine/Complete Inspection | No Violations Noted | Earthwork to bring the site into agreement with the PCSM plan had been completed. The disturbed areas had been stabilized with seed and mulch with the vegetation beginning to emerge. The vegetation had not yet attained 70% uniform coverage. There was no observed accelerated erosion or sedimentation. Brine tanks located onsite and they appeared to be in sound condition. |
2595908 | Primary Facility | 2017-05-19 | Routine/Complete Inspection | No Violations Noted | Well tagged-in production. Well head casing-production set equipment-tank battery-dike containment look ok. |
2668633 | Primary Facility | 2017-12-06 | Site Restoration | No Violations Noted | At time of inspection, wells 3H and 1H drilled and appear equipped for production. |
2748714 | Primary Facility | 2018-07-05 | Routine/Complete Inspection | No Violations Noted | This well is tagged and in production. The well head casing, piping, production set equipment, tank battery and containment dike look ok. |
2749026 | Primary Facility | 2018-07-05 | Routine/Complete Inspection | No Violations Noted | Multi-well pad. At time of inspection, wells 1H and 3H are both drilled and appear equipped for production. |