If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-005-31181 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.888469,"lon":-79.502486,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Armstrong | |
Municipality: East Franklin Township | |
Operator Name: SNYDER BROS INC | |
Well Pad ID: 150514 | |
Farm/Lease Name: LEWIS M WOLFE ETUX 1M-30 | |
License Status: | |
Spud Date: | |
Permit Date: 2013-11-07 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Vertical Well | |
Conservation: Yes | |
Latitude: 40.888469 | |
Longitude: -79.502486 |
Date | Event |
---|---|
2013-11-07 | New Permit Application |
2014-09-04 | Performed Spud Operation |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2014 | SNYDER BROS INC | 1,343.00 | 66 | 0.00 | 0 | 0.00 | 0 |
2015 | SNYDER BROS INC | 5,821.00 | 338 | 0.00 | 0 | 0.00 | 0 |
2016 | SNYDER BROS INC | 3,971.00 | 343 | 0.00 | 0 | 0.00 | 0 |
2017 | SNYDER BROS INC | 4,160.00 | 348 | 0.00 | 0 | 0.00 | 0 |
2018 | SNYDER BROS INC | 3,007.00 | 317 | 0.00 | 0 | 0.00 | 0 |
2019 | SNYDER BROS INC | 2,591.00 | 244 | 0.00 | 0 | 0.00 | 0 |
For data sources see[5]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2014 | SNYDER BROS INC | Drilling Fluid Waste | 110.00 Bbl | INJECTION DISPOSAL WELL | 34-155-23732 |
2014 | SNYDER BROS INC | Drill Cuttings | 112.00 Tons | ON SITE ENCAPSULATION | |
2014 | SNYDER BROS INC | Drilling Fluid Waste | 120.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NW009 |
2014 | SNYDER BROS INC | Drilling Fluid Waste | 620.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123SW005 |
2014 | SNYDER BROS INC | Drilling Fluid Waste | 681.00 Bbl | REUSE OTHER THAN ROAD SPREADING |
For data sources see[6]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2216862 | Primary Facility | 2013-10-24 | Routine/Complete Inspection | No Violations Noted | Inspection performed as part of the OG-57 waiver review process. The E&S plan as compiled should effectively minimize accelerated erosion and sedimentation provided it is implemented and maintained properly. It was noted in the E&S plan that the area for the drill pit will be evaluated to insure the bottom of the drill pit is at least 20 inches above the seasonal high groundwater table. When this evaluation is performed the Department requests that the operator forward a copy of this report for inclusion with the approved E&S plan. In addition should the evaluation show that the encapsulation of the drill cuttings and/or the utilization of a below grade drill pit is not feasbile the operator should forward this documentation and a revised E&S plan as a result of this evaluation. |
2233347 | Primary Facility | 2014-01-02 | Routine/Complete Inspection | No Violations Noted | Site construction had been completed, drilling had not commenced at the time of the inspection. SIte and access road E&S controls had been implemented as outlined in the E&S plan. There was no observed accelerated erosion or sedimentation in relation to the site or access road. |
2250418 | Primary Facility | 2014-03-04 | Routine/Complete Inspection | No Violations Noted | Drilling had not commenced at the time of the inspection. E&S controls had been implemented as outlined in the E&S plan. There was no observed accelerated erosion or sedimentation in relation to the site or access road. |
2266929 | Primary Facility | 2014-04-29 | Routine/Complete Inspection | No Violations Noted | Drilling had not commenced at the time of the inspection. E&S controls had been implemented as outlined in the E&S plan. There was no observed accelerated erosion or sedimentation in relation to the site or access road. |
2293469 | Primary Facility | 2014-08-07 | Routine/Complete Inspection | No Violations Noted | Drilling had not commenced at the time of the inspection. E&S controls had been implemented as outlined in the E&S plan. There was no observed accelerated erosion or sedimentation in relation to the site or access road. It was noted that the cut slope required additional seeding and mulching to achieve temporary stabilization. If the cut slope is left as is a more significant erosion issue could develop. |
2304233 | Primary Facility | 2014-09-16 | Routine/Complete Inspection | No Violations Noted | Dril rig onsite, drilling was ongoing at the time of the inspection. Lined drill pit located onsite and it contained drill cuttings and fluids. Drill pit had more than two feet of lined freeboard. There was no observed accelerated erosion or sedimentation in relation to the site or access road. |
2306674 | Primary Facility | 2014-09-12 | Drilling/Alteration | No Violations Noted | First Class Energy rig#10 RD20 shut down at time of inspection. No reps on location. Pit lined and freeboard maintained. |
2320425 | Primary Facility | 2014-11-05 | Routine/Complete Inspection | No Violations Noted | Drilling appeared to have been completed, well appeared to be equipped for production. Drill pit located onsite and it contained cuttings and fluids. Pit had more than two feet of lined freeboard. There was no observed accelerated erosion or sedimentation in relation to the site or access road. |
2357493 | Primary Facility | 2015-03-31 | Routine/Complete Inspection | No Violations Noted | Well appeared to be equipped for production, brine tanks located onsite and they appeared to be in sound condition. Site had been regraded, seeded & mulched. There was no observed accelerated erosion or sedimentation in relation to the site or access road. |
2394450 | Primary Facility | 2015-07-31 | Site Restoration | No Violations Noted | Well appeared to be equipped for production, however it did not appear to have been stimulated. The site had been effectively stabilized and there was no observed accelerated erosion or sedimentation in relation to the site or access road. |
2520854 | Primary Facility | 2016-09-21 | Routine/Complete Inspection | No Violations Noted | Well appeared to be equipped for production, however it did not appear to have been stimulated. The site had been effectively stabilized and there was no observed accelerated erosion or sedimentation in relation to the site or access road. |
For data sources see[7]