If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-005-31203 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.89711,"lon":-79.655815,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Armstrong | |
Municipality: Sugarcreek Township | |
Operator Name: APEX ENERGY (PA) LLC | |
Well Pad ID: 151333 | |
Farm/Lease Name: PETERSON | |
License Status: Active | |
Spud Date: 2014-07-21 | |
Permit Date: 2014-05-09 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: Yes | |
Latitude: 40.897110 | |
Longitude: -79.655815 |
Date | Event |
---|---|
2014-05-09 | New Permit Application |
2014-07-21 | Performed Spud Operation |
For data sources see[4]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2014-10-07 | 2014-10-16 | 6,142 | 10,210,800 | 0 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | Water | Customer & CWS | Base Fluid & Mix Water | Water | 7732-18-5 | 100 | 87.9853 | 85,496,700.0 |
Sand (Proppant), DAP-903, DAP-925, DWP-614, BioClear 2000, Hydrochloric Acid |
CWS | Propping Agent, Scale Inhibitor, Acid Corrosion Inhibitor, Viscosifier, Biocide, Clean Perforations | Biotite | 1302-27-8 | 0.1 | 0.00333 | 3233.07 | |
Hydrochloric acid | 7647-01-0 | 37 | 0.18033 | 175229 | ||||
Poly(oxyethylene)nonylphenol ether | 9016-45-9 | 5 | 0.003 | 2910.83 | ||||
Methanol | 67-56-1 | 60 | 0.00012 | 117 | ||||
Formaldehyde | 50-00-0 | 0.1 | 0 | 0.2 | ||||
Fatty acids | Proprietary | 30 | 0.00006000 | 58.5 | ||||
Modified thiourea polymer | 68527-49-1 | 30 | 0.00006000 | 58.5 | ||||
Olefin | Proprietary | 5 | 0.00001000 | 9.75 | ||||
Sorbitan monooleate | 1338-43-8 | 5 | 0.003 | 2910.83 | ||||
Polyethylene glycol mixture | 25322-68-3 | 70 | 0.01262 | 12265.1 | ||||
Goethite | 1310-14-1 | 0.1 | 0.0052 | 5054.07 | ||||
2-Propenoic acid, polymer with 2-propenamide, sodium salt | 25987-30-8 | 40 | 0.02396 | 23286.6 | ||||
2-Propenoic acid, polymer with sodium phosphonate | 71050-62-9 | 60 | 0.0067 | 6511.53 | ||||
Propargyl Alcohol | 107-19-7 | 10 | 0.00002000 | 19.5 | ||||
Illite | 12173-60-3 | 1 | 0.00645 | 6270.94 | ||||
Apatite | 64476-38-6 | 0.1 | 0.00333 | 3233.07 | ||||
Polyoxyalkylenes | Proprietary | 30 | 0.00006000 | 58.5 | ||||
Distillates (petroleum), hydrotreated middle | 64742-46-7 | 30 | 0.01797 | 17465 | ||||
Crystalline silica (Quartz) | 14808-60-7 | 100 | 11.7138 | 11,382,500.0 | ||||
Ilmenite | 98072-94-7 | 0.1 | 0.00239 | 2322.57 | ||||
Sodium chloride | 7647-14-5 | 1 | 0 | 1.95 | ||||
Calcite | 471-34-1 | 1 | 0.01968 | 19120.5 | ||||
2,2-Dibromo-3-Nitrilopropionamide | 10222-01-2 | 20 | 0.01262 | 12265.1 |
For data sources see[5]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2014 | APEX ENERGY (PA) LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2015 | APEX ENERGY (PA) LLC | 683,497.00 | 349 | 0.00 | 0 | 2,069.33 | 265 |
2016 | APEX ENERGY (PA) LLC | 1,251,722.00 | 298 | 0.00 | 0 | 1,126.70 | 181 |
2017 | APEX ENERGY (PA) LLC | 1,105,729.51 | 319 | 0.00 | 0 | 953.89 | 150 |
2018 | APEX ENERGY (PA) LLC | 817,582.00 | 294 | 0.00 | 0 | 165.02 | 280 |
2019 | APEX ENERGY (PA) LLC | 952,830.00 | 365 | 0.00 | 0 | 25.30 | 273 |
For data sources see[6]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2015 | APEX ENERGY (PA) LLC | Produced Fluid | 982.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123SW005 |
2015 | APEX ENERGY (PA) LLC | Produced Fluid | 300.00 Bbl | CENT WASTE TRT FAC NPDES DISCHARGE | PA0254185 |
2015 | APEX ENERGY (PA) LLC | Produced Fluid | 285.00 Bbl | INJECTION DISPOSAL WELL | 34-155-21438 |
2015 | APEX ENERGY (PA) LLC | Produced Fluid | 300.00 Bbl | CENT WASTE TRT FAC NPDES | PA0254185 |
2015 | APEX ENERGY (PA) LLC | Produced Fluid | 2,122.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NW009 |
2015 | APEX ENERGY (PA) LLC | Produced Fluid | 890.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016 | APEX ENERGY (PA) LLC | Produced Fluid | 4,988.00 Bbl | INJECTION DISPOSAL WELL | 34-155-23196 |
2016 | APEX ENERGY (PA) LLC | Produced Fluid | 330.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NW009 |
2016 | APEX ENERGY (PA) LLC | Produced Fluid | 1,430.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016 | APEX ENERGY (PA) LLC | Produced Fluid | 3,325.00 Bbl | INJECTION DISPOSAL WELL | 34-155-24078 |
2016 | APEX ENERGY (PA) LLC | 570.00 Bbl | INJECTION DISPOSAL WELL | 34-155-23196 | |
2016 | APEX ENERGY (PA) LLC | Produced Fluid | 220.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123SW005 |
2017 | APEX ENERGY (PA) LLC | 3,260.00 Bbl | INJECTION DISPOSAL WELL | 34-155-23196 | |
2017 | APEX ENERGY (PA) LLC | 80.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW009 | |
2017 | APEX ENERGY (PA) LLC | Produced Fluid | 3,455.00 Bbl | INJECTION DISPOSAL WELL | 34-155-23196 |
2017 | APEX ENERGY (PA) LLC | Produced Fluid | 80.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW009 |
2018 | APEX ENERGY (PA) LLC | Other Oil & Gas Wastes | 330.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2018 | APEX ENERGY (PA) LLC | Produced Fluid | 130.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW009 |
2019 | APEX ENERGY (PA) LLC | Other Oil & Gas Wastes | 100.00 Bbl | INJECTION DISPOSAL WELL | 34-155-23196 |
2019 | APEX ENERGY (PA) LLC | Produced Fluid | 2,335.00 Bbl | INJECTION DISPOSAL WELL | 34-155-23223 |
2019 | APEX ENERGY (PA) LLC | Other Oil & Gas Wastes | 320.00 Bbl | INJECTION DISPOSAL WELL | 34-155-23223 |
2019 | APEX ENERGY (PA) LLC | Produced Fluid | 3,065.00 Bbl | INJECTION DISPOSAL WELL | 34-155-23196 |
For data sources see[7]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2287665 | Primary Facility | 2014-07-16 | Drilling/Alteration | No Violations Noted | Pre-spud meeting with Operator. Department representatives; OGI Supervisor E. Ritzer, OGI D. Catalano, OGI R. Hoover. |
2291087 | Primary Facility | 2014-07-22 | Drilling/Alteration | No Violations Noted | Ziegenfuss concentric rig drilling and setting conductor at 30’ at time of inspection. |
2291093 | Primary Facility | 2014-07-30 | Drilling/Alteration | No Violations Noted | Waiting on rig to run and cement 13 3/8” casing and resume tophole drilling. |
2294434 | Primary Facility | 2014-08-05 | Drilling/Alteration | No Violations Noted | First Class Energy rig#10 running 9 5/8” casing at time of inspection. |
2295870 | Primary Facility | 2014-08-15 | Routine/Complete Inspection | No Violations Noted | Drilling was not ongoing at the time of the inspection. E&S controls had been implemented as outlined in the E&S plan contained within the ESCGP. There was no observed accelerated erosion or sedimentation in relation to the site or access road. |
2306663 | Primary Facility | 2014-09-15 | Drilling/Alteration | No Violations Noted | HWD rig#11 super single tripping out of hole after retrieving bridge plug from 6100’ pilot hole at time of inspection. Closed loop system being utilized. |
2325331 | Primary Facility | 2014-12-02 | Routine/Complete Inspection | No Violations Noted | Drilling and well stimulation activities appeared to have been completed. Work was underway to equp the well for production. Secondary containment was in the process of being removed during the inspection. All E&S controls appeared to be functioning properly and had been installed as outlined in the ESCGP for the site. There was no observed accelerated erosion or sedimentation in relation to the site or access road. |
2346511 | Primary Facility | 2015-02-24 | Routine/Complete Inspection | No Violations Noted | Well was equipped for and in production at the time of production. Brine and blowdown tanks located onsite and they appeared to be in sound condition. Site was snow covered and thus E&S control evaluation was not feasible. |
2365462 | Primary Facility | 2015-04-29 | Routine/Complete Inspection | No Violations Noted | Well was equipped for and in production at the time of production. Brine and blowdown tanks located onsite and they appeared to be in sound condition. There was no observed accelerated erosion or sedimentation in relation to the site or access road. |
2422129 | Primary Facility | 2015-10-30 | Routine/Complete Inspection | No Violations Noted | Well appeared to be equipped for and in production at the time of production. Brine tanks located onsite within secodnary containment and they appeared to be in sound condition. There was no observed accelerated erosion or sedimentation in relation to the site or access road. |
2445811 | Primary Facility | 2016-02-01 | Routine/Complete Inspection | No Violations Noted | Well tagged-in production. Well head casing-equipment-production unit-tank battery-dike look ok. |
2607011 | Primary Facility | 2017-06-23 | Routine/Complete Inspection | No Violations Noted | Well appeared to be equipped for production. Brine and condensate tanks located onsite within secondary containment. Tanks and containment appeared to be in sound condition. There was no observed accelerated erosion in relation to the site or access road. All implemented erosion controls appeared to be functioning properly, including the infiltration basin located onsite. |
2685871 | Primary Facility | 2018-01-24 | Routine/Complete Inspection | No Violations Noted | This well is tagged and in production. The well head casing, piping, production set equipment, and 3 fluid collection tanks with containment dikes all look ok. |
2823276 | Primary Facility | 2019-01-08 | Routine/Complete Inspection | No Violations Noted | This well is tagged and in production. The well head casing, piping, production set equipment, containment dikes and tank battery look ok. |
For data sources see[8]