X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-005-31254

Well Details

Well ID: 37-005-31254
Loading map...
Country: United States
State: Pennsylvania
County: Armstrong
Municipality: South Buffalo Township
Operator Name: MDS ENERGY DEV LLC
Well Pad ID: 152316
Farm/Lease Name: BIBLICAL LIFE
License Status: Active
Spud Date: 2016-05-12
Permit Date: 2016-03-04
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 40.743794
Longitude: -79.646678

For data sources see[1][2][3]

Well History

Date Event
2016-03-04 New Permit Application
2016-04-11 Drilling Completion
2016-04-13 Begin Plugging
2016-04-13 Finished Plugging
2016-05-11 Performed Spud Operation
2019-06-06 Fully Plugged
2019-06-06 Newly Drilled

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2016-07-18 2016-08-06 6,688 13,593,600 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 KSI-16NW Keane Scale Inhibitor Alkyl phosphonic acid Proprietary 3 0.000268758 340.923
ammonia, anhydrous 7664-41-7 0.3 0.00002688 34.092
Sand (Proppant) Keane Proppant Silica Substrate 14808-60-7 100 9.81265 12,447,500.0
Hydrochloric Acid (15%) FSTI Acidizing Water 7732-18-5 85 0.562057 712978
Hydrochloric Acid 7647-01-0 15 0.0991866 125820
FR-16FW Keane Friction Reducer Oleic Acid Diethanolamide 93-83-4 1.5 0.00110657 1403.7
Ammonium chloride 12125-02-9 1.5 0.00110657 1403.7
Alcohols, C12-16, ethoxylated 68551-12-2 1 0.000737715 935.803
Water 7732-18-5 55 0.0405743 51469.1
distillates (petroleum), hydrotreated light 64742-47-8 17.5 0.01291 16376.5
KFR-25 Keane Friction Reducer Water 7732-18-5 50 0.00309807 3929.94
Alcohols, C12-16, ethoxylated 68551-12-2 1.5 0.00009294 117.898
Ammonium chloride 12125-02-9 2 0.000123923 157.198
Oleic Acid Diethanolamide 93-83-4 1.5 0.00009294 117.898
distillates (petroleum), hydrotreated light 64742-47-8 18.5 0.00114629 1454.08
MBC-516 Keane Biocide Glutaraldehyde 111-30-8 27 0.00243074 3083.43
Didecyl dimethyl ammonium chloride 7173-51-5 8.3 0.000747227 947.869
N-alkyl dimethyl benzyl ammonium chloride 68424-85-1 5.5 0.000495151 628.106
Ethanol 64-17-5 2.8 0.000252077 319.763
AI-600P Weatherford Corrosion Inhibitor 1-Octanol 111-87-5 3 0.00004820 61.146
Methanol 67-56-1 1.8 0.00002812 35.669
Triethyl Phosphate 78-40-0 1.8 0.00002812 35.669
Dimethylformamide 68-12-2 15 0.000241016 305.732
Ethylene Glycol 107-21-1 30 0.000482032 611.465
1-Decanol 112-30-1 3 0.00004820 61.146
Pyridine, alkyl derives, quaternized with Benzyl chloride 68909-18-2 10 0.000160677 203.822
Alkyl Pyridine 68391-11-7 0.6 0.00000884 11.21
2-Butoxyethanol 111-76-2 3 0.00004820 61.146
Nonyl Phenol Ethoxylate, Branched 127087-87-0 10 0.000160677 203.822
Cinnamaldehyde 104-55-2 10 0.000160677 203.822
Water Snyder Brothers Carrier/Base Fluid Water 7732-18-5 100 89.4266 113,439,000.0

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2016 MDS ENERGY DEV LLC 188,862.00 31 0.00 0 0.00 0
2017 MDS ENERGY DEV LLC 2,002,926.00 347 0.00 0 0.00 0
2018 MDS ENERGY DEV LLC 1,716,372.00 365 0.00 0 0.00 0
2019 MDS ENERGY DEV LLC 1,321,118.00 365 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2016 MDS ENERGY DEV LLC Fracturing Fluid Waste 687.06 Bbl INJECTION DISPOSAL WELL 34-155-24063
2016 MDS ENERGY DEV LLC 4,016.37 Bbl REUSE OTHER THAN ROAD SPREADING
2016 MDS ENERGY DEV LLC 687.06 Bbl INJECTION DISPOSAL WELL 34-155-24063
2016 MDS ENERGY DEV LLC Fracturing Fluid Waste 264.92 Bbl INJECTION DISPOSAL WELL 34-007-24355
2016 MDS ENERGY DEV LLC 104.81 Bbl INJECTION DISPOSAL WELL 34-133-24462
2016 MDS ENERGY DEV LLC Produced Fluid 253.28 Bbl INJECTION DISPOSAL WELL 34-155-24079
2016 MDS ENERGY DEV LLC 253.28 Bbl INJECTION DISPOSAL WELL 34-155-24079
2016 MDS ENERGY DEV LLC Produced Fluid 311.50 Bbl INJECTION DISPOSAL WELL 34-155-23196
2016 MDS ENERGY DEV LLC Drill Cuttings 1,314.53 Tons LANDFILL 100585
2016 MDS ENERGY DEV LLC Fracturing Fluid Waste 3,792.20 Bbl REUSE OTHER THAN ROAD SPREADING
2016 MDS ENERGY DEV LLC Synthetic Liner Materials 1.55 Tons LANDFILL 100434
2016 MDS ENERGY DEV LLC Produced Fluid 508.01 Bbl INJECTION DISPOSAL WELL 34-155-24063
2016 MDS ENERGY DEV LLC Produced Fluid 224.17 Bbl REUSE OTHER THAN ROAD SPREADING
2016 MDS ENERGY DEV LLC 1,292.60 Bbl INJECTION DISPOSAL WELL 34-099-23158
2016 MDS ENERGY DEV LLC Other Oil & Gas Wastes 1.15 Tons LANDFILL 100585
2016 MDS ENERGY DEV LLC 264.92 Bbl INJECTION DISPOSAL WELL 34-007-24355
2016 MDS ENERGY DEV LLC 337.41 Bbl INJECTION DISPOSAL WELL 34-155-23196
2016 MDS ENERGY DEV LLC Fracturing Fluid Waste 1,292.60 Bbl INJECTION DISPOSAL WELL 34-099-23158
2016 MDS ENERGY DEV LLC Produced Fluid 1,533.27 Bbl INJECTION DISPOSAL WELL 34-099-23158
2016 MDS ENERGY DEV LLC Fracturing Fluid Waste 50.73 Tons LANDFILL 100585
2016 MDS ENERGY DEV LLC Produced Fluid 104.81 Bbl INJECTION DISPOSAL WELL 34-133-24462
2016 MDS ENERGY DEV LLC Fracturing Fluid Waste 397.41 Bbl INJECTION DISPOSAL WELL 34-155-23196
2017 MDS ENERGY DEV LLC 8,758.81 Bbl INJECTION DISPOSAL WELL 34-155-24079
2017 MDS ENERGY DEV LLC 4,745.06 Bbl REUSE (AT WELL PAD)
2017 MDS ENERGY DEV LLC Waste Water Treatment Sludge 6.47 Tons LANDFILL 100594
2017 MDS ENERGY DEV LLC 1.72 Tons LANDFILL 100594
2017 MDS ENERGY DEV LLC Synthetic Liner Materials 4.58 Tons LANDFILL 100594
2017 MDS ENERGY DEV LLC Produced Fluid 798.52 Bbl INJECTION DISPOSAL WELL 34-099-23158
2017 MDS ENERGY DEV LLC Waste Water Treatment Sludge 4.24 Tons LANDFILL 100585
2017 MDS ENERGY DEV LLC 32.02 Bbl INJECTION DISPOSAL WELL 34-099-23158
2017 MDS ENERGY DEV LLC Produced Fluid 10,207.13 Bbl INJECTION DISPOSAL WELL 34-155-24079
2017 MDS ENERGY DEV LLC Synthetic Liner Materials 3.31 Tons LANDFILL 100585
2017 MDS ENERGY DEV LLC Produced Fluid 5,272.00 Bbl REUSE (AT WELL PAD)
2018 MDS ENERGY DEV LLC Produced Fluid 12,193.20 Bbl INJECTION DISPOSAL WELL 34-099-23158
2018 MDS ENERGY DEV LLC Produced Fluid 599.70 Bbl REUSE (AT WELL PAD)
2018 MDS ENERGY DEV LLC Produced Fluid 299.90 Bbl INJECTION DISPOSAL WELL 34-155-24079
2019 MDS ENERGY DEV LLC Produced Fluid 295.50 Bbl INJECTION DISPOSAL WELL 34-099-23171
2019 MDS ENERGY DEV LLC Produced Fluid 1,557.50 Bbl REUSE (AT WELL PAD)
2019 MDS ENERGY DEV LLC Produced Fluid 77.10 Bbl INJECTION DISPOSAL WELL 34-099-2-3171
2019 MDS ENERGY DEV LLC Produced Fluid 7,784.50 Bbl INJECTION DISPOSAL WELL 34-099-23158

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2463270 Primary Facility 2016-03-10 Preoperation Inspection No Violations Noted Site construction had been effectively completed as outlined in the E&S plan contained within the ESCGP. All E&S controls had been constructed and all disturbed earth had been temporarily stabilized. There was no observed accelerated erosion or sedimentation in relation to the site or access road.
2466905 Primary Facility 2016-03-21 Drilling/Alteration No Violations Noted Set 6'x6' cellar 3/14/16/ Drilled 32" hole to 40' set 40' of 26" conductor-grouted inside-out. Drilled mouse hole to 65'-ran 12" casing -grouted.
2467295 Primary Facility 2016-03-23 Routine/Complete Inspection No Violations Noted Drilling had commenced but was not ongoing at the time of the inspection. All site and acces sroad E&S controls outlined in the E&S plan within the ESCGP had been properly implemented. Al disturbed areas had been temporarily stabilized.
2474531 Primary Facility 2016-04-13 Drilling/Alteration No Violations Noted Rig ran-cemented 855' of 13 3/8" pipe with 665 sks cement. Pipe parted @ 411'. Ran camera-saw gap in pipe/cement from 411' to 442'. Notified Department of defective casing/cement with plan to plug-skid.
2486082 Primary Facility 2016-05-19 Drilling/Alteration No Violations Noted First Class Energy Rig had TD'd hole @ 5700' and was tripping pipe out of hole @ time of this inspection. Site equipment looked ok. Nomac 78 finishing Rig was moving equipment in.
2486443 Primary Facility 2016-05-23 Routine/Complete Inspection No Violations Noted Drilling had commenced, but was not ongoing at the time of the inspection. Work was underway to set up the NOMAC drilling rig onsite. Also final touches were being made on the construction of the freshwater impundment and its security fencing along with the tank pad for the flowback tanks to be located onsite. There was no observed accelerated erosion or sedimentation in relation to the site or access road. All erosion controls had been implemented and maintained as outlined in the E&S plan contained within the ESCGP.
2488153 Primary Facility 2016-05-27 Drilling/Alteration No Violations Noted Nomac Rig #78 drilling in the curve @ 6,550' at time of inspection. Drilling log info, BOP test, drilling site equipment looked ok.
2495392 Primary Facility 2016-06-23 Routine/Complete Inspection No Violations Noted Drilling appeared to have been completed, NOMAC drilling rig had been rigged down and moved off-site. OG-71 approved Aboveground Storare Tank (AST) had been constructed onsite in preparation for well stimulation activities. Freshwater impoundment construction had been completed, the impoundment had been lined, and was being filled with purchased water from a nearby hydrant. All disturbed areas had been temporarily stabilized with vegetation. E&S controls had been implemented and maintained as outlined in the E&S plan within the ESCGP and there was no observed accelerated erosion or sedimentation in relation to the site or access road.
2500122 Primary Facility 2016-07-06 Drilling/Alteration No Violations Noted Equipment was being moved in and staged for the frac at the time of this inspection. Well head casing and equipment looked ok.
2552208 Primary Facility 2017-01-13 Routine/Complete Inspection No Violations Noted Drilling had been completed, wells were equipped for production. Brine tanks located onsite within secondary containment. Tanks and containment appeared to be in sound condition. Site had been constructed, E&S Controls had been maintained and the site had been stabilized with vegetation as outlined in the E&S plan contained within the ESCGP. Based upon the condition if the site and the completeness of the Restoration Extension Request submission the request will be granted extending the restoration deadline until March 15, 2019.
2569473 Primary Facility 2017-03-08 Routine/Complete Inspection No Violations Noted Well tagged-in production. Well head casing-production set equipment-tank battery-dike containment looked ok.
2589356 Primary Facility 2017-05-02 Routine/Complete Inspection No Violations Noted All site and access road erosion controls had been properly implemented and maintained as outlined in the ESCGP. There was no observed accelerated erosion or sedimentation in relation to the site or access road. Site had been effectively stabilized with vegetative cover. Waste fluid storage tanks located onsite within secondary containment. Both the tanks and containment appeared to be in sound condition. Well development impoundment located onsite and it contained withdrawn fluids.
2595534 Primary Facility 2017-05-17 Routine/Complete Inspection No Violations Noted Well tagged-on. Well head casing-production set equipment-tank battery-dike containment look ok.
2689112 Primary Facility 2018-01-31 Routine/Partial Inspection No Violations Noted Multi-well pad. At time of inspection, well 1H drilled and appears equipped for production. Wells 2H, 3H, and 4H all drilled and appear equipped for production.
2766356 Primary Facility 2018-08-23 Routine/Complete Inspection No Violations Noted This well is tagged and in production. The annulus is open. The well head casing, piping, production set equipment, containment dike and tank battery look ok.
2821580 Primary Facility 2019-01-03 Routine/Complete Inspection No Violations Noted This well is tagged and in production with the annulus open. The well head casing, piping, production set equipment, containment dike and tank battery look ok.

For data sources see[8]

References