If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-005-31286 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.913975,"lon":-79.373367,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Armstrong | |
Municipality: Boggs Township | |
Operator Name: SNYDER BROS INC | |
Well Pad ID: 154069 | |
Farm/Lease Name: KUHNS 2H | |
License Status: | |
Spud Date: | |
Permit Date: 2017-07-31 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: No | |
Latitude: 40.913975 | |
Longitude: -79.373367 |
Date | Event |
---|---|
2017-07-31 | New Permit Application |
2017-09-05 | Performed Spud Operation |
For data sources see[4]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2017-12-05 | 2017-12-17 | 6,684 | 9,819,050 | 0 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | Hydrochloric Acid (15%) | Keane | Acid Inhibitor | Water | 7732-18-5 | 85 | 0.504429 | 466793 |
Hydrochloric Acid | 7647-01-0 | 15 | 0.0890169 | 82375.3 | ||||
Sand (Proppant) | Keane | Proppant | Crystalline silica: Quartz (SiO2) | 14808-60-7 | 100 | 10.7624 | 9,959,450.0 | |
Water | Ascent | Carrier/Base Fluid | Water | 7732-18-5 | 100 | 88.5466 | 81,940,000.0 | |
KSI-19 | Keane | Scale Inhibitor | Methanol | 67-56-1 | 30 | 0.00394562 | 3651.23 | |
MBC-516 | Keane | Biocide | glutaral | 111-30-8 | 26.7 | 0.00253068 | 2341.86 | |
quaternary ammonium compounds, benzyl-C12-16-alkyldimethyl, chlorides |
68424-85-1 | 5.3 | 0.000503292 | 465.741 | ||||
didecyldimethylammonium chloride | 7173-51-5 | 8 | 0.000755412 | 699.05 | ||||
Other Chemical(s) | Listed Above | See Trade Name(s) List | prop-2-yn-1-ol | 107-19-7 | 5 | 0.00005877 | 54.383 | |
ammonium chloride | 12125-02-9 | 1.5 | 0.00110607 | 1023.55 | ||||
xylene | 1330-20-7 | 5 | 0.00005877 | 54.383 | ||||
Fatty imidazoline | 61790-69-0 | 5 | 0.00005877 | 54.383 | ||||
isoproyl alcohol | 67-63-0 | 5 | 0.00005877 | 54.383 | ||||
didecyldimethylammonium chloride | 7173-51-5 | 8 | 0.000755412 | 699.05 | ||||
quaternary ammonium compounds, benzyl-C12-16-alkyldimethyl, chlorides |
68424-85-1 | 5.3 | 0.000503292 | 465.741 | ||||
ethylbenzene | 100-41-4 | 1 | 0.00001175 | 10.877 | ||||
Distillates (petroleum), hydrotreated light | 64742-47-8 | 20 | 0.0147477 | 13647.3 | ||||
oleic acid diethanolamide | 93-83-4 | 1.5 | 0.00110607 | 1023.55 | ||||
alcohols, C12-16, ethoxylated | 68551-12-2 | 1 | 0.000737383 | 682.366 | ||||
Water | 7732-18-5 | 85 | 0.504429 | 466793 | ||||
Alcohols, C7-9-iso-, C8-rich | 68526-83-0 | 5 | 0.00005877 | 54.383 | ||||
Water | 7732-18-5 | 92.5 | 0 | 0 | ||||
KFR-16FW | Keane | Friction Reducer | oleic acid diethanolamide | 93-83-4 | 1.5 | 0.00110607 | 1023.55 | |
alcohols, C12-16, ethoxylated | 68551-12-2 | 1 | 0.000737383 | 682.366 | ||||
Distillates (petroleum), hydrotreated light | 64742-47-8 | 20 | 0.0147477 | 13647.3 | ||||
Water | 7732-18-5 | 60 | 0.044243 | 40941.9 | ||||
ammonium chloride | 12125-02-9 | 1.5 | 0.00110607 | 1023.55 | ||||
KAI-12 | Keane | Acid Inhibitor | ethylbenzene | 100-41-4 | 1 | 0.00001175 | 10.877 | |
Fatty imidazoline | 61790-69-0 | 5 | 0.00005877 | 54.383 | ||||
prop-2-yn-1-ol | 107-19-7 | 5 | 0.00005877 | 54.383 | ||||
isoproyl alcohol | 67-63-0 | 5 | 0.00005877 | 54.383 | ||||
Alcohols, C7-9-iso-, C8-rich | 68526-83-0 | 5 | 0.00005877 | 54.383 | ||||
xylene | 1330-20-7 | 5 | 0.00005877 | 54.383 | ||||
Methanol | 67-56-1 | 90 | 0.00105781 | 978.89 |
For data sources see[5]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2017 | SNYDER BROS INC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2018 | SNYDER BROS INC | 601,744.00 | 148 | 0.00 | 0 | 0.00 | 0 |
2019 | SNYDER BROS INC | 815,530.00 | 336 | 0.00 | 0 | 0.00 | 0 |
For data sources see[6]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2017 | SNYDER BROS INC | Drill Cuttings | 448.29 Tons | INJECTION DISPOSAL WELL | 34-155-24079 |
2017 | SNYDER BROS INC | Drilling Fluid Waste | 34.80 Bbl | INJECTION DISPOSAL WELL | 34-099-23158 |
2017 | SNYDER BROS INC | Produced Fluid | 65.30 Bbl | REUSE (AT WELL PAD) | |
2017 | SNYDER BROS INC | Drilling Fluid Waste | 65.30 Bbl | REUSE (AT WELL PAD) | |
2017 | SNYDER BROS INC | Drill Cuttings | 1,355.57 Tons | LANDFILL | 100585 |
2017 | SNYDER BROS INC | Drilling Fluid Waste | 970.57 Bbl | INJECTION DISPOSAL WELL | 34-155-24079 |
2018 | SNYDER BROS INC | Synthetic Liner Materials | 8.87 Tons | LANDFILL | 100585 |
2018 | SNYDER BROS INC | Drill Cuttings | 4.58 Tons | LANDFILL | 100585 |
2018 | SNYDER BROS INC | Produced Fluid | 652.90 Bbl | REUSE (AT WELL PAD) | |
2018 | SNYDER BROS INC | Produced Fluid | 714.90 Bbl | INJECTION DISPOSAL WELL | 34-155-24079 |
2018 | SNYDER BROS INC | Produced Fluid | 25,442.00 Bbl | INJECTION DISPOSAL WELL | 34-099-23158 |
2018 | SNYDER BROS INC | Filter Socks | 0.60 Tons | LANDFILL | 100585 |
2018 | SNYDER BROS INC | Produced Fluid | 52.76 Tons | LANDFILL | 100585 |
2018 | SNYDER BROS INC | Produced Fluid | 76.10 Bbl | INJECTION DISPOSAL WELL | 34-155-23196 |
2019 | SNYDER BROS INC | Produced Fluid | 483.40 Bbl | INJECTION DISPOSAL WELL | 34-099-23171 |
2019 | SNYDER BROS INC | Produced Fluid | 12,031.00 Bbl | INJECTION DISPOSAL WELL | 34-099-23158 |
2019 | SNYDER BROS INC | Produced Fluid | 2,902.10 Bbl | REUSE (AT WELL PAD) |
For data sources see[7]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2633821 | Primary Facility | 2017-09-08 | Routine/Complete Inspection | No Violations Noted | Drilling had commenced but was not ongoing at the time if the inspection. There was no observed accelerated erosion or sedimentation in relation to the site or access road. All erosion controls had been implemented as outlined in the E&S plan included within the ESCGP. |
2656149 | Primary Facility | 2017-11-02 | Drilling/Alteration | No Violations Noted | The Rig was tripping out of the hole from the TD @ 12217' at the time of this inspection. Tripping pipe out @ 7000'. Plan is to cement 5 1/2" production casing to surface in the morning. The drilling log information and all equipment on site looked ok. |
2668393 | Primary Facility | 2017-12-06 | Routine/Complete Inspection | No Violations Noted | At time of inspection, stimulation activities ongoing for Wells 1H and 2H. |
2673338 | Primary Facility | 2017-12-20 | Routine/Complete Inspection | No Violations Noted | At time of inspection, wells 2H and 1H have been frac'd, flow back has not yet occurred. Equipment is currently being removed from the location. |
2681347 | Primary Facility | 2018-01-11 | Routine/Complete Inspection | No Violations Noted | At time of inspection, plugs are being drilled out as part of the flowback process for wells 1H and 2H. |
2707391 | Primary Facility | 2018-03-20 | Routine/Partial Inspection | No Violations Noted | Inspection conducted in response to spud notifications for wells 3H, 4H, and 5H.
At time of inspection, wells 1H and 2H drilled and frac'd. Well 3H drilled to 40 feet and covered with steel plate. Wells 4H and 5H drilled to 40 feet and covered with steel plates. Department unable to adequately inspect the entire location due to ongoing high pressure testing occurring on part of the well pad. |
2724437 | Primary Facility | 2018-04-18 | Routine/Partial Inspection | No Violations Noted | At time of inspection, well 2H drilled and frac'd. Well 1H also drilled and frac'd. Wells 3H, 4H, and 5H spudded, not yet completed, covered with steel plates. |
2743294 | Primary Facility | 2018-06-13 | Routine/Partial Inspection | No Violations Noted | At time of inspection, well 2H drilled and frac'd. Well 1H also drilled and frac'd.
Drilling rig currently on-site. Wells 3H, 4H, and 5H previously spudded, not yet frac'd. |
2818049 | Primary Facility | 2018-12-17 | Routine/Complete Inspection | No Violations Noted | At time of inspection well appears to be in production. Well head surrounded by cement barriers. Three brine tanks on site.
No activity taking place on site at this time. |
2823166 | Primary Facility | 2019-01-08 | Routine/Complete Inspection | No Violations Noted | This well is tagged, in production and temporarily shut in for a sales line upgrade which is taking place at the time of this inspection in order to provide additional pipeline capacity for the 5 wells on this unconventional well pad. The well head casing, piping, production set equipment, containment dike and tank battery look ok. |
2828383 | Primary Facility | 2019-01-17 | Routine/Complete Inspection | No Violations Noted | On 1/17/19 at 0903 hrs., I conducted a routine inspection of Snyder Brothers, Inc.'s Kuhns well pad and associated wells in Boggs Twp., Armstrong Co. Five wells have been drilled and are equipped for production, including well 2H (API 005-31286). Well tags are present at the well heads. There are no violations noted for this inspection. |
2853261 | Primary Facility | 2019-03-05 | Routine/Partial Inspection | No Violations Noted | At the time of inspection, well was producing. Well integrity was in good condition, with no signs of any leaks or spills onsite. The well did not have any corrosion. The cellar was below ground level, with water inside. No bubbles were seen. The digital gauges on the well showed the tubing pressure to be 1339 psi and the casing pressure was 1659 psi. The well was properly labeled and the Emergency Response sign was posted at the site entrance. There were 3 dual line heaters and 5 separators onsite. The 1H & 2H wells had smaller separators than the rest of the wells. There were also 3 tall tanks and a smaller horizontal tank contained within a lined, steel dike. |
For data sources see[8]