X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-015-20115

Well Details

Well ID: 37-015-20115
Loading map...
Country: United States
State: Pennsylvania
County: Bradford
Municipality: West Burlington Township
Operator Name: CHIEF OIL & GAS LLC
Well Pad ID: 148620
Farm/Lease Name: JENNINGS UNIT 1H
License Status: ACTIVE
Spud Date:
Permit Date: 2008-12-01
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.742969
Longitude: -76.620871

For data sources see[1][2][3]

Well History

Date Event
2008-12-01 New Permit Application
2008-12-09 Performed Spud Operation
2009-03-12 DEVIATED
2010-04-02 Perforation

For data sources see[4]


Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2008 CHIEF OIL & GAS LLC 0.00 0 0.00 0 0.00 0
2009 CHIEF OIL & GAS LLC 0.00 0 0.00 0 0.00 0
2010 CHIEF OIL & GAS LLC 13,432.00 164 0.00 0 0.00 0
2011 CHIEF OIL & GAS LLC 142,516.00 331 0.00 0 0.00 0
2012 CHIEF OIL & GAS LLC 34,556.33 357 0.00 0 0.00 0
2013 CHIEF OIL & GAS LLC 21,434.00 359 0.00 0 0.00 0
2014 CHIEF OIL & GAS LLC 16,996.00 356 0.00 0 0.00 0
2015 CHIEF OIL & GAS LLC 10,779.06 362 0.00 0 0.00 0
2016 CHIEF OIL & GAS LLC 9,530.44 346 0.00 0 0.00 0
2017 CHIEF OIL & GAS LLC 7,885.21 365 0.00 0 0.00 0
2018 CHIEF OIL & GAS LLC 6,121.17 365 0.00 0 0.00 0
2019 CHIEF OIL & GAS LLC 6,348.32 363 0.00 0 0.00 0

For data sources see[5]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2009 CHIEF OIL & GAS LLC Brine 400.00 Bbl Brine or Industrial Waste Treatment Plt PA0008451
2009 CHIEF OIL & GAS LLC Fracking Fluid 130.00 Bbl Brine or Industrial Waste Treatment Plt PA0101508
2009 CHIEF OIL & GAS LLC Fracking Fluid 400.00 Bbl Brine or Industrial Waste Treatment Plt PA0027057
2009 CHIEF OIL & GAS LLC Drilling 20,707.00 Bbl Brine or Industrial Waste Treatment Plt PA0101508
2010 CHIEF OIL & GAS LLC Drilling Fluid Waste 1,680.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0101508
2010 CHIEF OIL & GAS LLC Drilling Fluid Waste 2,118.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0027057
2010 CHIEF OIL & GAS LLC Fracing Fluid Waste 1,075.50 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0027057
2010 CHIEF OIL & GAS LLC Produced Fluid 170.00 Bbl INJECTION DISPOSAL WELL 34-155-23795
2010 CHIEF OIL & GAS LLC Produced Fluid 714.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0008451
2010 CHIEF OIL & GAS LLC Produced Fluid 65.50 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0101508
2011 CHIEF OIL & GAS LLC Fracing Fluid Waste 99.00 Bbl REUSE OTHER THAN ROAD SPREADING
2011 CHIEF OIL & GAS LLC Fracing Fluid Waste 240.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE EPA ID: 748-163
2011 CHIEF OIL & GAS LLC Fracing Fluid Waste 2,243.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0008451
2012 CHIEF OIL & GAS LLC Produced Fluid 94.50 Bbl REUSE OTHER THAN ROAD SPREADING
2013 CHIEF OIL & GAS LLC Produced Fluid 182.70 Bbl REUSE OTHER THAN ROAD SPREADING
2014 CHIEF OIL & GAS LLC Produced Fluid 28.00 Bbl REUSE OTHER THAN ROAD SPREADING
2015 CHIEF OIL & GAS LLC Produced Fluid 18.37 Bbl REUSE OTHER THAN ROAD SPREADING

For data sources see[6]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1754412 Primary Facility 2008-12-04 Routine/Complete Inspection Violation(s) Noted
1761968 Primary Facility 2009-01-12 Routine/Complete Inspection No Violations Noted
1966598 Primary Facility 2011-03-31 Compliance Evaluation No Violations Noted
1976270 Primary Facility 2011-05-26 Routine/Partial Inspection Violation(s) Noted
2017458 Primary Facility 2011-11-07 Follow-up Inspection No Violations Noted
2049152 Primary Facility 2012-03-07 Follow-up Inspection No Violations Noted
2324560 Primary Facility 2014-11-14 Routine/Complete Inspection No Violations Noted
2491256 Primary Facility 2016-06-06 Routine/Complete Inspection No Violations Noted
2497035 Primary Facility 2016-06-29 Routine/Complete Inspection No Violations Noted Construction Inspection Conducted on 6/29/2016. Arrived: 12:00 Departed: 13:00.

The 1H well was in the production phase and the 2H is being prepared for plugging. Two poly/felt liner containments are in use by around the two well heads. The two corroided production tanks are still on site on site but are no longer being used for production (the lines are disconnected). A poly water buffalo tank was plumbed into the production waste line and placed within containment. The operator informed the DEP that the poly tank would be sufficient because the 1H does not produce a great deal of waste water.

Margaret Farrell with Chief Oil and Gas was contacted by phone on 6/29/2016 and she will inform the DEP once the corroided production tanks are removed from the location.

Well API Inspection ID Status Previous Inspection Violations 1H 015-20115 2497035 Production Ready 6/6/2016 No 2H 015-20283 2497037 Pre

2597214 Primary Facility 2017-05-24 Routine/Complete Inspection No Violations Noted The 1H well is staged for production. The 2H well is plugged. No leaks detected from production equipment. Site stable. No violations enforced at this time.
2614268 Primary Facility 2017-07-11 Routine/Complete Inspection No Violations Noted Inspection to assess overall site conditions. No violations cited.
2682660 Primary Facility 2018-01-16 Plugging(Includes Plugged/Mined Through) No Violations Noted Routine inspection of a plugged well. The 2H is plugged with a 2" candy cane vent as a monument. No obvious issues were observed. There is also a well in production on the pad; the 1H. I conducted a visual inspection of the well. There were no obvious issues.
2802235 Primary Facility 2018-11-09 Site Restoration No Violations Noted NOT approval.

Electrical conductivity readings taken from pooled water on site with an Oakton PCSTestr 35. A puddle near the center of the pad gave a 0.11 mS/cm reading. JLP

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
1754412 552299 12/04/2008 2008-12-04 201G - Failure to post permit number, operator name, address, telephone number in a conspicuous manner at the site during drilling Administrative
1976270 612213 05/26/2011 2011-05-26 78.56(1) - Pit and tanks not constructed with sufficient capacity to contain pollutional substances. Administrative High conductivity in puddles (2-8 mS/cm) on right corner area of pad. Puddles elsewhere on pad are low cond. Investigating identity and source of high cond. Sample: 2371084,085.

Penalties Applied

Violation ID Penalty ID Penalty Code Penalty Status Penalty Date Enforcement Date Penalty Amount Amount Collected
552299 241085 NOV - Notice of Violation Comply/Closed 2009-01-12

For data sources see[7]

References