37-015-20277

Well Details

Well ID: 37-015-20277
Loading map...
Country: United States
State: Pennsylvania
County: Bradford
Municipality: Springfield Township
Operator Name: EOG RESOURCES INC
Well Pad ID: 146991
Farm/Lease Name: HARKNESS 2H
License Status:
Spud Date:
Permit Date: 2009-05-14
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.860615
Longitude: -76.677019

For data sources see[1][2][3]

Well History

Date Event
2009-05-14 New Permit Application
2010-02-23 Performed Spud Operation
2010-03-16 Permit Renewal Application
2011-02-16 Perforation
2011-09-20 DEVIATED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2011-02-19 2011-02-19 5,421 4,538,184

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Ferrotrol 300L Baker Hughes Iron Control
Citric acid 77-92-9 70.00 0.00811000
Frac Sand (All Meshes) CWT Baker Hughes Proppant Quartz 14808-60-7 100.00 11.31
FRW-18 Baker Hughes Friction Reducer
Distillates, petroleum, hydrotreated light 64742-47-8 30.00 0.02
CI-14 Baker Hughes Corrosion Inhibitor Olefin 5.00 0.00007000
Propargyl alcohol 107-19-7 5.00 0.00007000
Polyoxyalkylenes 30.00 0.00040000
Methanol 67-56-1 100.00 0.00133000
Fatty Acids 10.00 0.00013000
Water Operator Carrier
Water 7732-18-5 100.00 86.84
Scaletrol 720 Baker Hughes Scale Inhibitor Diethylene glycol 111-46-6 5.00 0.00056000
Ethylene glycol 107-21-1 45.00 0.00503000
Hydrochloric Acid 10.1-15 Baker Hughes Acidizing Hydrochloric acid 7647-01-0 15.00 0.26
Water 7732-18-5 85.00 1.51
Alpha 1427 Baker Hughes Biocide Water 7732-18-5 60.00 0.01
Glutaraldehyde 111-30-8 30.00 0.00705000
Quaternary ammonium compounds,
benzyl-C12-16-alkyldimethyl, chlorides
68424-85-1 7.00 0.00164000
Ethanol 64-17-5 5.00 0.00117000
Didecyl dimethyl ammonium chloride 7173-51-5 10.00 0.00235000

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2009 EOG RESOURCES INC 0.00 0 0.00 0 0.00 0
2010 EOG RESOURCES INC 0.00 0 0.00 0 0.00 0
2011 EOG RESOURCES INC 715,333.00 275 0.00 0 0.00 0
2012 EOG RESOURCES INC 836,370.00 366 0.00 0 0.00 0
2013 EOG RESOURCES INC 558,699.00 365 0.00 0 0.00 0
2014 EOG RESOURCES INC 412,557.32 365 0.00 0 0.00 0
2015 EOG RESOURCES INC 317,020.33 365 0.00 0 0.00 0
2016 EOG RESOURCES INC 266,910.28 366 0.00 0 0.00 0
2017 EOG RESOURCES INC 229,104.37 365 0.00 0 0.00 0
2018 EOG RESOURCES INC 195,194.37 365 0.00 0 0.00 0
2019 EOG RESOURCES INC 171,365.11 365 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2011 EOG RESOURCES INC Produced Fluid 5,303.00 Bbl REUSE OTHER THAN ROAD SPREADING
2011 EOG RESOURCES INC Drill Cuttings 248.88 Tons LANDFILL 31346244
2012 EOG RESOURCES INC Produced Fluid 254.00 Bbl STORAGE PENDING DISPOSAL OR REUSE
2012 EOG RESOURCES INC Produced Fluid 490.00 Bbl REUSE OTHER THAN ROAD SPREADING
2013 EOG RESOURCES INC Produced Fluid 94.50 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW018
2013 EOG RESOURCES INC Produced Fluid 306.00 Bbl REUSE OTHER THAN ROAD SPREADING
2014 EOG RESOURCES INC Produced Fluid 345.50 Bbl REUSE OTHER THAN ROAD SPREADING
2015 EOG RESOURCES INC Produced Fluid 297.82 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2016 EOG RESOURCES INC Produced Fluid 75.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123
2016 EOG RESOURCES INC Produced Fluid 28.00 Bbl INJECTION DISPOSAL WELL 34-133-24462
2016 EOG RESOURCES INC Produced Fluid 116.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2017 EOG RESOURCES INC Produced Fluid 126.45 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2017 EOG RESOURCES INC 129.00 Bbl REUSE (AT WELL PAD)
2017 EOG RESOURCES INC Produced Fluid 129.00 Bbl REUSE (AT WELL PAD)
2017 EOG RESOURCES INC 49.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2018 EOG RESOURCES INC Produced Fluid 254.00 Bbl REUSE (AT WELL PAD)
2019 EOG RESOURCES INC Produced Fluid 30.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123
2019 EOG RESOURCES INC Produced Fluid 100.00 Bbl REUSE (AT WELL PAD)

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1871335 Primary Facility 2010-03-17 Drilling/Alteration Viol(s) Noted & Immediately Corrected
1947395 Primary Facility 2011-02-03 Routine/Complete Inspection No Violations Noted Ran pipe to TD in preparation to perforate. Fracing expected to begin in approx. 3 weeks.
1981278 Primary Facility 2011-06-02 Routine/Complete Inspection Violation(s) Noted
1993526 Primary Facility 2011-08-05 Follow-up Inspection Violation(s) Noted
1993633 Primary Facility 2011-07-07 Follow-up Inspection Violation(s) Noted This is a follow-up. High conductivity puddles first noted in inspection report # 1981278.
1997007 Primary Facility 2011-08-17 Follow-up Inspection Outstanding Violations - No Viols Req'd
2001692 Primary Facility 2011-09-07 Follow-up Inspection No Violations Noted
2169735 Primary Facility 2013-05-23 Routine/Complete Inspection No Violations Noted
2643635 Primary Facility 2017-10-04 Routine/Complete Inspection No Violations Noted Routine inspection to assess overall site conditions. No issues noted and no violations cited.
2715361 Primary Facility 2018-04-06 Routine/Complete Inspection No Violations Noted Cold/snowy at time of inspection

No annulus cents present at time of inspection.

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
1871335 583593 03/17/2010 2010-03-17 78.122 - Drillers Log not on site Administrative
1981278 613771 06/02/2011 2011-06-02 102.11 - Failure to design, implement or maintain BMPs to minimize the potential for accelerated erosion and sedimentation. Administrative On cut slope fronting onto well pad, there are large cracks and gashes where slope is slumping away.
1981278 613772 06/02/2011 2011-06-02 102.11 - Failure to design, implement or maintain BMPs to minimize the potential for accelerated erosion and sedimentation. Administrative At toe of slope on east side. trench has been breached, silt sock is not in place, stakes have been pulled out of ground and sediment is moving off site.
1981278 613773 06/02/2011 2011-06-02 102.11 - Failure to design, implement or maintain BMPs to minimize the potential for accelerated erosion and sedimentation. Administrative At toe of slope on east side. trench has been breached, silt sock is not in place, stakes have been pulled out of ground and sediment is moving off site.
1993526 617043 08/05/2011 2011-08-05 SWMA301 - Failure to properly store, transport, process or dispose of a residual waste. Environmental Health & Safety Production fluid leak from containment onto well pad.
1993526 617044 08/05/2011 2011-08-05 402CSL - Failure to adopt pollution prevention measures required or prescribed by DEP by handling materials that create a danger of pollution. Environmental Health & Safety Production fluid leak from containment onto well pad.
1993526 617045 08/05/2011 2011-08-05 91.33A - Failure to notify DEP of pollution incident. No phone call made forthwith Administrative No notification was attempted or made.
1993526 617191 08/05/2011 2011-08-05 78.57 - Failure to post pit approval number Administrative Viol Type Description: Chapter 78.57(a) of the Rules and Regulations of the Environmental Quality Board
1993633 617065 07/07/2011 2011-07-07 78.56(1) - Pit and tanks not constructed with sufficient capacity to contain pollutional substances. Administrative 78.56(a) The operator shall contain pollutional substances. Results of sampling high conductivity puddles showed that the pollutional substances (water with elevated Sr, Cl, Br, Ba) was not contained.
1993633 617066 07/07/2011 2011-07-07 SWMA301 - Failure to properly store, transport, process or dispose of a residual waste. Environmental Health & Safety Residual waste was discharged onto the ground.
1993633 617067 07/07/2011 2011-07-07 91.33A - Failure to notify DEP of pollution incident. No phone call made forthwith Administrative The department was not notified about these leaks or spills.

For data sources see[8]

References