37-015-20581

Well Details

Well ID: 37-015-20581
Loading map...
Country: United States
State: Pennsylvania
County: Bradford
Municipality: Herrick Township
Operator Name: SWN PROD CO LLC
Well Pad ID: 148327
Farm/Lease Name: HECKMAN CAMP G U 1H
License Status:
Spud Date:
Permit Date: 2009-12-29
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.772192
Longitude: -76.225341

For data sources see[1][2][3]

Well History

Date Event
2009-12-29 New Permit Application
2010-01-07 Performed Spud Operation
2010-06-15 DEVIATED
2010-11-03 Perforation

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2010-10-24 2010-10-24 6,355 4,443,432

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Hydrochloric Acid, 10.1-15 BHI Acidizing Hydrochloric Acid 7647-01-0 15.0 0.00356
Scaletrol 720 BHI Scale Inhibitor Ethylene Glycol 107-21-1 45.0 0.00489
Hydrochloric Acid, 5.1-7.5 BHI Acidizing Hydrochloric Acid 7647-01-0 7.5 0.08013
Fatty Acids CBI 10.0 0.00043
Diethylene Glycol 111-46-6 5.0 0.00054
Olefin CBI 5.0 0.00022
Alkyl Dimethyl Benzyl Ammonium Chloride (C12-16) 68424-85-1 7.0 0.00173
Quaternary Ammonium Chloride 7173-51-5 10.0 0.00247
Water 7732-18-5 92.5 0.98831
Propargyl Alcohol 107-19-7 5.0 0.00022
Water 7732-18-5 85.0 0.02018
Water 7732-18-5 60.0 0.01484
Ethanol 64-17-5 5.0 0.00124
Polyoxyalkylenes CBI 30.0 0.0013
Frac Sand (All Meshes) CWT BHI Proppant Crystalline Silica (Quartz) 14808-60-7 100.0 7.95506
FRW-18 BHI Friction Reducer Hydrotreated Light Distillate 64742-47-8 30.0 0.02459
Clay Master-5C BHI Clay Control Oxyakylated Amine Quat 138879-94-4 60.0 0.00043
Alpha 1427 BHI Biocide Glutaraldehyde 111-30-8 30.0 0.00742
Water Operator Carrier Water 7732-18-5 100.0 90.88144
CI-14 BHI Corrosion Inhibitor Methanol 67-56-1 100.0 0.00435
Diagnostic Tracer Protechnics Diagnostic Sodium Salt Trade Secret 10.0 0.00008000
Ferrotrol 300L BHI Iron Control Citric Acid 77-92-9 70.0 0.00665

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2009 SOUTHWESTERN ENERGY PROD CO 0.00 0 0.00 0 0.00 0
2010 SOUTHWESTERN ENERGY PROD CO 231,323.00 43 0.00 0 0.00 0
2011 SOUTHWESTERN ENERGY PROD CO 2,167,507.00 349 0.00 0 0.00 0
2012 SOUTHWESTERN ENERGY PROD CO 1,208,021.00 342 0.00 0 0.00 0
2013 SOUTHWESTERN ENERGY PROD CO 1,207,470.00 363 0.00 0 0.00 0
2014 SOUTHWESTERN ENERGY PROD CO 848,492.00 351 0.00 0 0.00 0
2015 SWN PROD CO LLC 829,618.00 352 0.00 0 0.00 0
2016 SWN PROD CO LLC 636,853.00 366 0.00 0 0.00 0
2017 SWN PROD CO LLC 497,514.00 365 0.00 0 0.00 0
2018 SWN PROD CO LLC 403,425.00 365 0.00 0 0.00 0
2019 SWN PROD CO LLC 295,701.00 361 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2012 SOUTHWESTERN ENERGY PROD CO Fracturing Fluid Waste 0.95 Tons LANDFILL 101247
2013 SOUTHWESTERN ENERGY PROD CO Produced Fluid 1,480.00 Bbl REUSE OTHER THAN ROAD SPREADING
2014 SOUTHWESTERN ENERGY PROD CO Produced Fluid 1,040.00 Bbl REUSE OTHER THAN ROAD SPREADING
2015 SWN PROD CO LLC Produced Fluid 2,540.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016 SWN PROD CO LLC Produced Fluid 195.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC018
2016 SWN PROD CO LLC Produced Fluid 262.00 Bbl REUSE OTHER THAN ROAD SPREADING
2017 SWN PROD CO LLC Other Oil & Gas Wastes 17.83 Bbl SURFACE IMPOUNDMENT 826342
2017 SWN PROD CO LLC Produced Fluid 674.33 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2017 SWN PROD CO LLC Other Oil & Gas Wastes 10.00 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2017 SWN PROD CO LLC Produced Fluid 149.00 Bbl SURFACE IMPOUNDMENT 826342
2017 SWN PROD CO LLC Produced Fluid 18.33 Bbl REUSE (AT WELL PAD)
2017 SWN PROD CO LLC Produced Fluid 475.00 Bbl REUSE OTHER THAN ROAD SPREADING
2018 SWN PROD CO LLC Produced Fluid 212.32 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2018 SWN PROD CO LLC Produced Fluid 80.33 Bbl REUSE (AT WELL PAD)
2018 SWN PROD CO LLC Other Oil & Gas Wastes 18.33 Bbl REUSE (AT WELL PAD)
2018 SWN PROD CO LLC Produced Fluid 57.17 Bbl SURFACE IMPOUNDMENT 826342
2019 SWN PROD CO LLC Other Oil & Gas Wastes 11.00 Bbl SURFACE IMPOUNDMENT 826342
2019 SWN PROD CO LLC Produced Fluid 70.66 Bbl SURFACE IMPOUNDMENT 826342
2019 SWN PROD CO LLC Produced Fluid 18.33 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC035
2019 SWN PROD CO LLC Other Oil & Gas Wastes 35.42 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2019 SWN PROD CO LLC Produced Fluid 93.00 Bbl SURFACE IMPOUNDMENT 95-16-65420-013

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1863843 Primary Facility 2010-02-18 Routine/Complete Inspection De minimus Violations Noted Inadequate 102 BMPs, some in disrepair. No distance waiver for wetland. Will be corrected ASAP.
1865859 Primary Facility 2010-02-24 Drilling/Alteration No Violations Noted
1877335 Primary Facility 2010-04-14 Routine/Complete Inspection Violation(s) Noted SWN very cooperative. Awaiting instructions to correct/abate.
1884346 Primary Facility 2010-05-13 Compliance Evaluation Violation(s) Noted Following up on previous violations. Working toward resolution on old violations. New violations found. Drill mud spilling onto the ground while I was there - actively leaking from secondary containment.
1900924 Primary Facility 2010-07-21 Routine/Partial Inspection Violation(s) Noted
2005724 Primary Facility 2011-09-20 Complaint Inspection Violation(s) Noted On-site to conduct an inspection of the site in response to a water supply complaint with Trudy Graby, Oil and Gas Inspector, Briana Betress, Water Quality Specialist and Mike O¿Donnell, Water Quality Specialist Supervisor. There was no activity at the site during the inspection. DeSoto Drilling Rig #9 is utilizing this site for equipment storage. A petroleum sheen was observed in between two (2) generators in an area approximately 5 x 15 feet. The generators are not stored on containment and the fuel has made contact with the surface of the ground. This constitutes a violation of the Clean Streams Law, 35 P.S. § 691.402, 25 PA Code § 91.33 and 35 PS § 6018.610 of the PA Solid Waste Management Act. A UVIR sample was collected in this area to determine the presence of a petroleum product. The UV analysis from the 9/23/2011 DEP Bureau of Laboratories report indicated a weathered petroleum product was present.
2089699 Primary Facility 2012-08-02 Incident- Response to Accident or Event No Violations Noted Violations and specifics associated with this inspection report can be referred to in the Greenzweig Unit #7H inspection report. Permit number is 015-20952.
2095627 Primary Facility 2012-06-04 Routine/Complete Inspection No Violations Noted Cellar exposed, filled with water, however no visible bubbling. Well in production. .21 psi on 9 5/8; 135500 psi on 5 1/2
2100622 Primary Facility 2012-09-11 Follow-up Inspection No Violations Noted Specifics associated with this inspection report can be referred to in the Greenzweig 7H; 9-11-12 inspection report. Permit number is 015-20952.
2180785 Primary Facility 2013-07-01 Routine/Complete Inspection No Violations Noted
2337305 Primary Facility 2015-01-20 Incident- Response to Accident or Event No Violations Noted
2343510 Primary Facility 2015-02-11 Routine/Complete Inspection No Violations Noted Arrived onsite @ 12:25, sunny, temperature > freezing, pad snow-covered. There were 6 wells in production on the pad. The Ferguson-Keisling GU #1, Heckman-Hiduk GU #1, and Heckman-Camp GU #1 were in one row. The cellars on these wells were open. There were 3 digital Scada gauges on annuli for each of these well. The lowermost labeled, “Surface”, measured the pressure in the 9-5/8” x 5-1/2” casing. Higher on the wellhead, the “Casing” gauge measured the 5-1/2 x 2-3/8” annular pressure. The gauge on the top of the well head measured the tubing pressure, according to production superintendent Gary Dutton. The production units for these wells were near the western corner of the pad. The other three wells were also in a line but offset from the previous 3: Greenzweig 7H, Greenzweig 8H, and Heckman-Hiduk #2.
2667895 Primary Facility 2017-12-05 Routine/Complete Inspection No Violations Noted On December 5, 2017, the Department conducted a routine inspection at the SWN Production Company LLC, GU-G-Pad in Herrick Township, Bradford County. The Department was represented by Andrew Hobbins. Tracy Gregory was present for SWN.

The site sign, E & S plan and weekly inspection logs were on site and available for review. The site was well vegetated, and no E & S issues were observed during the inspection. The well pad has been reduced in size. A Notice of Termination was approved by the Department in November of 2015.

Six wells were in production during the inspection. The wells were labeled and no bubbling was observed in the well cellars. Two production tanks and six GPUs were also on site. Puddles on the pad were low in specific conductivity and no staining was observed on the well pad surface.

No violations were observed during this inspection.

2817043 Primary Facility 2018-12-18 Site Restoration No Violations Noted The DEP conducted a RESTORATION inspection of SWN's Heckman Camp G pad in Herrick Twp, Bradford County on 12/18/2018 at 1230 hours. The inspection was conducted in response to a Well Site Restoration Report received by the DEP.

This site has 6 producing wells onsite with two production tanks. The site is very well vegetated and steep slopes of the pad appear stabilized. All PCSM BMPs appeared to be in place and no temporary E&S BMPs were observed.

This Well Site Restoration Report is accepted.

No violations noted today, I departed the site at 1255.

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
1877335 585220 04/14/2010 2010-04-14 78.56PITCNST - Impoundment not structurally sound, impermeable, 3rd party protected, greater than 20" of seasonal high ground water table Administrative Company response rec'vd 5/4/10, corrections adequate, viol closed.
1877335 585221 04/14/2010 2010-04-14 301UNPMTIW - Industrial waste was discharged without permit. Environmental Health & Safety Company response rec'vd 5/4/10, corrections adequate, viol closed.
1877335 585222 04/14/2010 2010-04-14 402POTNLPOLL - There is a potential for polluting substance(s) reaching Waters of the Commonwealth and may require a permit. Environmental Health & Safety Company response rec'vd 5/4/10, corrections adequate, viol closed.
1877335 585223 04/14/2010 2010-04-14 78.56LINER - Improperly lined pit Administrative Company response rec'vd 5/4/10, corrections adequate, viol closed.
1884346 587003 05/13/2010 2010-05-13 78.56PITCNST - Impoundment not structurally sound, impermeable, 3rd party protected, greater than 20" of seasonal high ground water table Administrative 78.56(a) - failure to contain polluting substance
1884346 587004 05/13/2010 2010-05-13 301UNPMTIW - Industrial waste was discharged without permit. Environmental Health & Safety 6018.301 - residual waste - discharge of polluting substance to the ground
1884346 587005 05/13/2010 2010-05-13 402POTNLPOLL - There is a potential for polluting substance(s) reaching Waters of the Commonwealth and may require a permit. Environmental Health & Safety 691.402 - potential for polluting substance to reach waters of the commonwealth
1900924 591864 07/21/2010 2010-07-21 78.56(1) - Pit and tanks not constructed with sufficient capacity to contain pollutional substances. Administrative Failure to contain pollutional substance at the well site
1900924 591865 07/21/2010 2010-07-21 301UNPMTIW - Industrial waste was discharged without permit. Environmental Health & Safety 6018.301 - creation of residual waste - spill on ground contaminating soil
2005724 621023 09/20/2011 2011-09-20 402POTNLPOLL - There is a potential for polluting substance(s) reaching Waters of the Commonwealth and may require a permit. Environmental Health & Safety
2005724 621024 09/20/2011 2011-09-20 91.33POLLINC - Pollution incident was not reported to DEP. Environmental Health & Safety
2005724 621090 09/20/2011 2011-09-20 SWMA301 - Failure to properly store, transport, process or dispose of a residual waste. Environmental Health & Safety Violation should be 6018.610

Penalties Applied

Violation ID Penalty ID Penalty Code Penalty Status Penalty Date Enforcement Date Penalty Amount Amount Collected
585220 257009 NOV - Notice of Violation Comply/Closed 2010-05-04
585221 257009 NOV - Notice of Violation Comply/Closed 2010-05-04
585222 257009 NOV - Notice of Violation Comply/Closed 2010-05-04
585223 257009 NOV - Notice of Violation Comply/Closed 2010-05-04
587003 257796 NOV - Notice of Violation Comply/Closed 2010-08-16
587004 257796 NOV - Notice of Violation Comply/Closed 2010-08-16
587005 257796 NOV - Notice of Violation Comply/Closed 2010-08-16

For data sources see[8]