If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-015-20583 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.772275,"lon":-76.225246,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Bradford | |
Municipality: Herrick Township | |
Operator Name: SWN PROD CO LLC | |
Well Pad ID: 148327 | |
Farm/Lease Name: FERGUSON KEISLING GU 1H | |
License Status: | |
Spud Date: | |
Permit Date: 2009-12-23 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: No | |
Latitude: 41.772275 | |
Longitude: -76.225246 |
Date | Event |
---|---|
2009-12-23 | New Permit Application |
2010-01-07 | Performed Spud Operation |
2010-06-15 | DEVIATED |
2010-11-03 | Perforation |
For data sources see[4]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2010-10-23 | 2010-10-23 | 6,428 | 4,423,440 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | Hydrochloric Acid, 5.1-7.5 | BHI | Acidizing | Hydrochloric Acid | 7647-01-0 | 7.5 | 0.08085 | |
Polyoxyalkylenes | CBI | 30.0 | 0.0013 | |||||
Quaternary Ammonium Chloride | 7173-51-5 | 10.0 | 0.00245 | |||||
Sodium Sulfate | 7757-82-6 | 2.0 | 0.00019 | |||||
Olefin | CBI | 5.0 | 0.00022 | |||||
Propargyl Alcohol | 107-19-7 | 5.0 | 0.00022 | |||||
Ethanol | 64-17-5 | 5.0 | 0.00123 | |||||
Water | 7732-18-5 | 92.5 | 0.9972 | |||||
Diethylene Glycol | 111-46-6 | 5.0 | 0.00054 | |||||
Sodium Hydroxide | 1310-73-2 | 1.0 | 0.0001 | |||||
Alkyl Dimethyl Benzyl Ammonium Chloride (C12-16) | 68424-85-1 | 7.0 | 0.00172 | |||||
Water | 7732-18-5 | 60.0 | 0.0147 | |||||
Fatty Acids | CBI | 10.0 | 0.00043 | |||||
Diagnostic Tracer | Protechnics | Diagnostic | Sodium Salt | Trade Secret | 10.0 | 0.00008000 | ||
Alpha 1427 | BHI | Biocide | Glutaraldehyde | 111-30-8 | 30.0 | 0.00735 | ||
Water | Operator | Carrier | Water | 7732-18-5 | 100.0 | 91.28682 | ||
Ferrotrol 800L | BHI | Iron Control | Trisodium NTA | 18662-53-8 | 40.0 | 0.00387 | ||
Frac Sand (All Meshes) CWT | BHI | Proppant | Crystalline Silica (Quartz) | 14808-60-7 | 100.0 | 7.56659 | ||
CI-14 | BHI | Corrosion Inhibitor | Methanol | 67-56-1 | 100.0 | 0.00432 | ||
Scaletrol 720 | BHI | Scale Inhibitor | Ethylene Glycol | 107-21-1 | 45.0 | 0.00486 | ||
FRW-18 | BHI | Friction Reducer | Hydrotreated Light Distillate | 64742-47-8 | 30.0 | 0.02505 |
For data sources see[5]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2009 | SOUTHWESTERN ENERGY PROD CO | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2010 | SOUTHWESTERN ENERGY PROD CO | 233,834.00 | 42 | 0.00 | 0 | 0.00 | 0 |
2011 | SOUTHWESTERN ENERGY PROD CO | 1,816,775.00 | 354 | 0.00 | 0 | 0.00 | 0 |
2012 | SOUTHWESTERN ENERGY PROD CO | 1,024,950.00 | 345 | 0.00 | 0 | 0.00 | 0 |
2013 | SOUTHWESTERN ENERGY PROD CO | 909,889.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2014 | SOUTHWESTERN ENERGY PROD CO | 728,758.00 | 351 | 0.00 | 0 | 0.00 | 0 |
2015 | SWN PROD CO LLC | 591,776.00 | 345 | 0.00 | 0 | 0.00 | 0 |
2016 | SWN PROD CO LLC | 463,090.00 | 366 | 0.00 | 0 | 0.00 | 0 |
2017 | SWN PROD CO LLC | 396,524.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2018 | SWN PROD CO LLC | 318,706.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2019 | SWN PROD CO LLC | 240,665.00 | 361 | 0.00 | 0 | 0.00 | 0 |
For data sources see[6]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2012 | SOUTHWESTERN ENERGY PROD CO | Fracturing Fluid Waste | 2.16 Tons | LANDFILL | 101247 |
2013 | SOUTHWESTERN ENERGY PROD CO | Produced Fluid | 2,129.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014 | SOUTHWESTERN ENERGY PROD CO | Produced Fluid | 78.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2015 | SWN PROD CO LLC | Produced Fluid | 399.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016 | SWN PROD CO LLC | Produced Fluid | 100.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC018 |
2016 | SWN PROD CO LLC | Produced Fluid | 87.40 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2017 | SWN PROD CO LLC | Other Oil & Gas Wastes | 17.83 Bbl | SURFACE IMPOUNDMENT | 826342 |
2017 | SWN PROD CO LLC | Produced Fluid | 87.33 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2017 | SWN PROD CO LLC | Other Oil & Gas Wastes | 10.00 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2017 | SWN PROD CO LLC | Produced Fluid | 36.00 Bbl | SURFACE IMPOUNDMENT | 826342 |
2017 | SWN PROD CO LLC | Produced Fluid | 18.33 Bbl | REUSE (AT WELL PAD) | |
2018 | SWN PROD CO LLC | Produced Fluid | 212.32 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2018 | SWN PROD CO LLC | Produced Fluid | 80.33 Bbl | REUSE (AT WELL PAD) | |
2018 | SWN PROD CO LLC | Other Oil & Gas Wastes | 18.33 Bbl | REUSE (AT WELL PAD) | |
2018 | SWN PROD CO LLC | Produced Fluid | 57.17 Bbl | SURFACE IMPOUNDMENT | 826342 |
2019 | SWN PROD CO LLC | Other Oil & Gas Wastes | 11.00 Bbl | SURFACE IMPOUNDMENT | 826342 |
2019 | SWN PROD CO LLC | Produced Fluid | 70.66 Bbl | SURFACE IMPOUNDMENT | 826342 |
2019 | SWN PROD CO LLC | Produced Fluid | 18.33 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC035 |
2019 | SWN PROD CO LLC | Other Oil & Gas Wastes | 35.42 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2019 | SWN PROD CO LLC | Produced Fluid | 93.00 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
For data sources see[7]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
1879985 | Primary Facility | 2010-04-19 | Drilling/Alteration | No Violations Noted | pioneer rig 65 drilling @8216 ft deep. so far they have run 20 ft of 20 in casig/622 ft of 13 3/8 casing and 1597 ft of 9 5/8 casing. both cement jobs had cement to surface. |
2006005 | Primary Facility | 2011-09-20 | Complaint Inspection | No Violations Noted | Please refer to the Heckman-Camp GU 1H inspection report, Permit number 37-015-20581 for violations and comments. |
2095629 | Primary Facility | 2012-06-04 | Routine/Complete Inspection | No Violations Noted | Cellar exposed, no visible bubbling. .5 psi on 9 5/8. casing pressure 1365 psi. Unable to reading tubing pressure gauge. Well in production. |
2099623 | Primary Facility | 2012-08-02 | Incident- Response to Accident or Event | No Violations Noted | Violations and specifics associated with this inspection report can be referred to in the Greenzweig Unit #7H inspection report. Permit number is 015-20952. |
2100644 | Primary Facility | 2012-09-11 | Follow-up Inspection | No Violations Noted | |
2180787 | Primary Facility | 2013-07-01 | Routine/Complete Inspection | No Violations Noted | |
2337365 | Primary Facility | 2015-01-20 | Incident- Response to Accident or Event | No Violations Noted | |
2343507 | Primary Facility | 2015-02-11 | Routine/Complete Inspection | No Violations Noted | Arrived onsite @ 12:25, sunny, temperature > freezing, pad snow-covered. There were 6 wells in production on the pad. The Ferguson-Keisling GU #1, Heckman-Hiduk GU #1, and Heckman-Camp GU #1 were in one row. The cellars on these wells were open. There were 3 digital Scada gauges on annuli for each of these well. The lowermost labeled, “Surface”, measured the pressure in the 9-5/8” x 5-1/2” casing. Higher on the wellhead, the “Casing” gauge measured the 5-1/2 x 2-3/8” annular pressure. The gauge on the top of the well head measured the tubing pressure, according to production superintendent Gary Dutton. The production units for these wells were near the western corner of the pad. The other three wells were also in a line but offset from the previous 3: Greenzweig 7H, Greenzweig 8H, and Heckman-Hiduk #2. |
2677980 | Primary Facility | 2017-12-05 | Routine/Complete Inspection | No Violations Noted | On December 5, 2017, the Department conducted a routine inspection at the SWN Production Company LLC, GU-G-Pad in Herrick Township, Bradford County. The Department was represented by Andrew Hobbins. Tracy Gregory was present for SWN.
The site sign, E & S plan and weekly inspection logs were on site and available for review. The site was well vegetated, and no E & S issues were observed during the inspection. The well pad has been reduced in size. A Notice of Termination was approved by the Department in November of 2015. Six wells were in production during the inspection. The wells were labeled and no bubbling was observed in the well cellars. Two production tanks and six GPUs were also on site. Puddles on the pad were low in specific conductivity and no staining was observed on the well pad surface. No violations were observed during this inspection. |
2817048 | Primary Facility | 2018-12-18 | Site Restoration | No Violations Noted | The DEP conducted a RESTORATION inspection of SWN's Heckman Camp G pad in Herrick Twp, Bradford County on 12/18/2018 at 1230 hours. The inspection was conducted in response to a Well Site Restoration Report received by the DEP.
This site has 6 producing wells onsite with two production tanks. The site is very well vegetated and steep slopes of the pad appear stabilized. All PCSM BMPs appeared to be in place and no temporary E&S BMPs were observed. This Well Site Restoration Report is accepted. No violations noted today, I departed the site at 1255. |
For data sources see[8]