X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-015-20976

Well Details

Well ID: 37-015-20976
Loading map...
Country: United States
State: Pennsylvania
County: Bradford
Municipality: Columbia Township
Operator Name: REPSOL OIL & GAS USA LLC
Well Pad ID: 149543
Farm/Lease Name: WATSON 03 051 05 B 5H
License Status:
Spud Date:
Permit Date: 2010-06-15
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.871736
Longitude: -76.802189

For data sources see[1][2][3]

Well History

Date Event
2010-06-15 New Permit Application
2011-06-13 Permit Renewal Application
2011-07-20 Performed Spud Operation
2012-02-19 Perforation
2012-11-09 DEVIATED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2014-04-27 2014-05-15 5,807 4,827,600 0

Fluid Composition Data

-65 Scale Inhibitor
Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 FE-1A ACIDIZING COMPOSITION Halliburton Additive Acetic anhydride 108-24-7 100 0.0041289 2062
Acetic acid 64-19-7 60 0.00247734 1237
BE-9 Halliburton Biocide Tributyl tetradecyl phosphonium chloride 81741-28-8 10 0.00221368 1106
Fresh Water Operator Base Fluid Fresh Water 7732-18-5 100 80.5519 40,213,700.0
HYDROCHLORIC ACID 10-30% Halliburton Solvent Hydrochloric acid 7647-01-0 30 0.0107446 5364
HAI-OS ACID INHIBITOR Halliburton Corrosion Inhibitor Propargyl alcohol 107-19-7 10 0.00006828 35
Methanol 67-56-1 60 0.000409665 205
LCA-1 Halliburton Solvent Paraffinic solvent Confidential 100 0.00353249 1764
SAND - PREMIUM WHITE Halliburton Proppant Crystalline silica, quartz 14808-60-7 100 4.60727 2,300,080.0
FR-66 Halliburton Friction Reducer Hydrotreated light petroleum distillate 64742-47-8 30 0.0147406 7359
HYDROCHLORIC ACID 5-10% Halliburton Solvent Hydrochloric acid 7647-01-0 10 0.0553813 27648
Other Ingredient(s) Water 7732-18-5 0 0.657354 328170
Sodium chloride 7647-14-5 0 0.00245677 1227
Alcohols, C12-16, ethoxylated 68551-12-2 0 0.00245677 1227
Olefins Confidential 0 0.00003414 18
Polyacrylamide copolymer Confidential 0 0.0147406 7359
Ammonium chloride 12125-02-9 0 0.00245677 1227
Alcohols, C14-C15, ethoxylated 68951-67-7 0 0.000204832 103
Fatty acid tall oil amide Confidential 0 0.00245677 1227
Olefins Confidential 0 0.00000683 4
Reaction product of acetophenone,
formaldehyde, thiourea
and oleic acid in dimethyl formamide
68527-49-1 0 0.000204832 103
Formaldehyde 50-00-0 0 0.000268456 135
Sorbitan monooleate polyoxyethylene derivative 9005-65-6 0 0.000491354 246
Sorbitan, mono-9-octadecenoate, (Z) 1338-43-8 0 0.000491354 246
Organic phosphonate Confidential 0 0.0161074 8042
Fatty acids, tall oil Confidential 0 0.000204832 103
SAND - COMMON WHITE Halliburton Proppant Crystalline silica, quartz 14808-60-7 100 6.41574 3,202,920.0
Halliburton Scale Inhibitor Ammonium chloride 12125-02-9 10 0.00268456 1341
SAND - COMMON BROWN Halliburton Proppant Crystalline silica, quartz 14808-60-7 100 7.72903 3,858,550.0

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2010 REPSOL OIL & GAS USA LLC 0.00 0 0.00 0 0.00 0
2011 REPSOL OIL & GAS USA LLC 0.00 0 0.00 0 0.00 0
2012 REPSOL OIL & GAS USA LLC 0.00 0 0.00 0 0.00 0
2013 REPSOL OIL & GAS USA LLC 0.00 0 0.00 0 0.00 0
2014 REPSOL OIL & GAS USA LLC 739,454.60 216 0.00 0 0.00 0
2015 REPSOL OIL & GAS USA LLC 1,078,171.20 363 0.00 0 0.00 0
2016 REPSOL OIL & GAS USA LLC 600,774.60 366 0.00 0 0.00 0
2017 REPSOL OIL & GAS USA LLC 407,474.30 365 0.00 0 0.00 0
2018 REPSOL OIL & GAS USA LLC 315,785.30 365 0.00 0 0.00 0
2019 REPSOL OIL & GAS USA LLC 261,103.80 361 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2011 REPSOL OIL & GAS USA LLC Drill Cuttings 20.79 Tons LANDFILL NY31346244
2011 REPSOL OIL & GAS USA LLC Drill Cuttings 100.19 Tons LANDFILL NY # 02S17
2011 REPSOL OIL & GAS USA LLC Drill Cuttings 311.73 Tons LANDFILL 8-0728-0004/013
2014 REPSOL OIL & GAS USA LLC Fracing Fluid Waste 3,918.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2014 REPSOL OIL & GAS USA LLC Fracturing Fluid Waste 159.75 Tons LANDFILL 100361
2014 REPSOL OIL & GAS USA LLC Produced Fluid 16.83 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW018
2014 REPSOL OIL & GAS USA LLC Fracing Fluid Waste 10,773.25 Bbl REUSE OTHER THAN ROAD SPREADING
2014 REPSOL OIL & GAS USA LLC Produced Fluid 2,682.55 Bbl REUSE OTHER THAN ROAD SPREADING
2014 REPSOL OIL & GAS USA LLC Produced Fluid 117.95 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC010
2014 REPSOL OIL & GAS USA LLC Produced Fluid 190.71 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2015 REPSOL OIL & GAS USA LLC Produced Fluid 473.57 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2015 REPSOL OIL & GAS USA LLC Produced Fluid 1,114.83 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC010
2015 REPSOL OIL & GAS USA LLC Produced Fluid 1,850.96 Bbl REUSE OTHER THAN ROAD SPREADING
2016 REPSOL OIL & GAS USA LLC Produced Fluid 62.21 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2016 REPSOL OIL & GAS USA LLC Produced Fluid 163.28 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC010
2016 REPSOL OIL & GAS USA LLC Produced Fluid 1,014.57 Bbl REUSE OTHER THAN ROAD SPREADING
2017 REPSOL OIL & GAS USA LLC Produced Fluid 783.35 Bbl REUSE (AT WELL PAD)
2018 REPSOL OIL & GAS USA LLC Produced Fluid 398.88 Bbl REUSE (AT WELL PAD)
2018 REPSOL OIL & GAS USA LLC Produced Fluid 200.52 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2019 REPSOL OIL & GAS USA LLC Other Oil & Gas Wastes 43.50 Bbl REUSE (AT WELL PAD)
2019 REPSOL OIL & GAS USA LLC Produced Fluid 46.44 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2019 REPSOL OIL & GAS USA LLC Produced Fluid 351.41 Bbl REUSE (AT WELL PAD)

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2113495 Primary Facility 2012-10-22 Routine/Complete Inspection No Violations Noted
2113942 Primary Facility 2012-10-22 Routine/Complete Inspection No Violations Noted
2172731 Primary Facility 2013-06-04 Routine/Complete Inspection No Violations Noted 4 gas wells in production, 4 others not producing. puddles 0.9-2.4 mS/cm
2270592 Primary Facility 2014-05-14 Routine/Complete Inspection No Violations Noted
2574127 Primary Facility 2017-03-22 Routine/Complete Inspection No Violations Noted Eight Wells in production phase. Eight water separators within containment. No leaks detected from production equipment. Site stable. No violations noted.
2694510 Primary Facility 2018-02-14 Routine/Complete Inspection No Violations Noted Inspection to assess overall site conditions. No violations noted.
2792559 Primary Facility 2018-10-22 Routine/Complete Inspection No Violations Noted The DEP conducted a routine inspection of Repsol's Watson B (03-051) well pad in Columbia Twp, Bradford County on 10/22/2018 at 1220 hours. The weather was 41 degrees, 65% humidity and cloudy.

There are currently 8 active wells and two production tanks onsite. All fluids measured on the pad surface were within normal conductivity ranges. The fluids within containment were also within normal ranges. No erosional issues were found on the pad itself but some very minor channels were observed on the access road.

No violations noted at this time. I departed the site at 1240.

2803385 Primary Facility 2018-11-07 Site Restoration No Violations Noted The DEP conducted a RESTORATION inspection of Repsol Oil & Gas's Watson B (03-051) well pad in Columbia Township, Bradford County on 11/7/2018 at 1130 hours. The inspection was conducted in response to a Notice of Termination received by the DEP. The weather was 52 degrees and partly cloudy.

There are currently 8 producing wells onsite with two production tanks. PCSM BMPs are in place and appear to be functioning properly.

Along the entire length of the southeastern side of the pad, filter sock is in place that appears to have been buried by the pad material. There are many instances where this filter sock is now exposed due to eroding pad material (see photos numbered 3 to 8). According to 25 Pa. Code 102.22(a)(1) the removal of E&S BMPs is necessary upon site stabilization in order for the NOT to be approved. Permanent stabilization per 25 Pa. Code 102.22(a)(2) must also be accomplished.

Upon permanently stabilizing this edge of the pad and complete removal of the filter sock, this NOT may then be app

For data sources see[8]

References