X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-015-21117

Well Details

Well ID: 37-015-21117
Loading map...
Country: United States
State: Pennsylvania
County: Bradford
Municipality: Orwell Township
Operator Name: CHESAPEAKE APPALACHIA LLC
Well Pad ID: 149203
Farm/Lease Name: ROBINSON 2H
License Status: Inactive
Spud Date:
Permit Date: 2010-08-17
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.849631
Longitude: -76.2944

For data sources see[1][2][3]

Well History

Date Event
2010-08-17 New Permit Application
2010-09-09 Performed Spud Operation
2011-02-20 Perforation
2012-11-09 DEVIATED
2018-05-14 Inactive Well Request Granted

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2011-02-27 2011-02-27 5,046 4,292,652

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Recycled Produced Water Carrier/Base Fluid 0.66
Scale Inhibitor - Gyptron T-390 Champion Technologies Scale Inhibitor Methanol 67-56-1 10.00 0.00115000
Sand (Proppant) Proppant 12.23
Bactron K-87 Microbiocide Champion Technologies Bactericide Alkyl* dimethyl ethylbenzyl ammonium
chloride *(50%C12, 30%C14, 17%C16, 3%C18)
85409-23-0 10.00 0.00332000
Ethanol 64-17-5 1.00 0.00033000
Glutaraldehyde 111-30-8 30.00 0.00995000
B-315 Schlumberger Friction Reducer Distillates, petroleum, hydrotreated light 64742-47-8 30.00 0.01
Aliphatic alcohol polyglycol ether 1.50 0.00069000
Acid, Hydrochloric 15pct Schlumberger Acid Hydrochloric acid 7647-01-0 15.00 0.11
Water 7732-18-5 85.00 0.66
A261 Corrosion Inhibitor Schlumberger Corrosion Inhibitor Methanol 67-56-1 10.00 0.00015000
Propan-2-ol 5.00 0.00007000
Formalin 50-00-0 5.00 0.00007000
Aliphatic alcohol polyglycol ether 13.00 0.00019000
Aromatic ketones 100.00 0.00148000
Propargyl alcohol 107-19-7 5.00 0.00007000
Aromatic hydrocarbon 5.00 0.00007000
Aliphatic acid 5.00 0.00007000
Fresh Water Carrier/Base Fluid 86.21
L058 Schlumberger Iron Control Agent Sodium erythorbate 6381-77-7 100.00 0.00437000

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2010 CHESAPEAKE APPALACHIA LLC 0.00 0 0.00 0 0.00 0
2011 CHESAPEAKE APPALACHIA LLC 0.00 0 0.00 0 0.00 0
2012 CHESAPEAKE APPALACHIA LLC 2,360.00 29 0.00 0 0.00 0
2013 CHESAPEAKE APPALACHIA LLC 107,470.00 113 0.00 0 0.00 0
2014 CHESAPEAKE APPALACHIA LLC 245,285.00 342 0.00 0 0.00 0
2015 CHESAPEAKE APPALACHIA LLC 111,874.00 209 0.00 0 0.00 0
2016 CHESAPEAKE APPALACHIA LLC 84,955.00 280 0.00 0 0.00 0
2017 CHESAPEAKE APPALACHIA LLC 15,869.00 108 0.00 0 0.00 0
2018 CHESAPEAKE APPALACHIA LLC 9,602.00 113 0.00 0 0.00 0
2019 CHESAPEAKE APPALACHIA LLC 20,160.00 335 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2011 CHESAPEAKE APPALACHIA LLC Drilling Fluid Waste 2,530.00 Bbl REUSE OTHER THAN ROAD SPREADING
2011 CHESAPEAKE APPALACHIA LLC Fracing Fluid Waste 431.00 Bbl REUSE OTHER THAN ROAD SPREADING
2012 CHESAPEAKE APPALACHIA LLC Produced Fluid 7,380.60 Bbl REUSE OTHER THAN ROAD SPREADING
2013 CHESAPEAKE APPALACHIA LLC Produced Fluid 729.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC007
2013 CHESAPEAKE APPALACHIA LLC Fracing Fluid Waste 200.00 Bbl REUSE OTHER THAN ROAD SPREADING
2013 CHESAPEAKE APPALACHIA LLC Fracing Fluid Waste 25.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC008
2013 CHESAPEAKE APPALACHIA LLC Produced Fluid 6,763.00 Bbl REUSE OTHER THAN ROAD SPREADING
2014 CHESAPEAKE APPALACHIA LLC Produced Fluid 4,326.33 Bbl REUSE OTHER THAN ROAD SPREADING
2015 CHESAPEAKE APPALACHIA LLC Produced Fluid 116.50 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC018
2015 CHESAPEAKE APPALACHIA LLC Produced Fluid 675.48 Bbl REUSE OTHER THAN ROAD SPREADING
2016 CHESAPEAKE APPALACHIA LLC Produced Fluid 12.50 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC008
2016 CHESAPEAKE APPALACHIA LLC Produced Fluid 152.50 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC018
2016 CHESAPEAKE APPALACHIA LLC Produced Fluid 526.50 Bbl REUSE OTHER THAN ROAD SPREADING
2016 CHESAPEAKE APPALACHIA LLC Other Oil & Gas Wastes 56.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC018
2016 CHESAPEAKE APPALACHIA LLC Produced Fluid 66.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NW011
2016 CHESAPEAKE APPALACHIA LLC Produced Fluid 52.50 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC010
2016 CHESAPEAKE APPALACHIA LLC Produced Fluid 59.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2017 CHESAPEAKE APPALACHIA LLC Produced Fluid 144.50 Bbl REUSE (AT WELL PAD)

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1942745 Primary Facility 2011-01-11 Drilling/Alteration No Violations Noted Nomac 8. Spudding well on 1/12/11 at approx 0700. Water based mud to start. Switching over to oil based at 4600'. Plan on using Schulumberger to cement.
2013140 Primary Facility 2011-10-24 Routine/Complete Inspection No Violations Noted 0 psi on all gauges. (venting surface string). Cellar filled with water, however no visible bubbling.
2142805 Primary Facility 2013-01-17 Routine/Complete Inspection No Violations Noted 0 psi on 9 x 13 (ventted); -2.9634 on 9 x 5; 2.0205 on 5 1/2; 9.7650 on production tubing. 2 cond tanks; 2 seperators. No visible bubbling.
2224719 Primary Facility 2013-11-15 Routine/Complete Inspection No Violations Noted prod well. Comp on site.
2373726 Primary Facility 2015-05-21 Routine/Complete Inspection No Violations Noted
2510193 Primary Facility 2016-08-09 Routine/Complete Inspection No Violations Noted On August 9, 2016 at 1145 hrs., the Department conducted a routine inspection at the Chesapeake Appalachia, LLC (Chesapeake) Robinson Well Pad Location in Orwell Township, Bradford County. The Department was represented by Andrew Hobbins, Water Quality Specialist. Chesapeake did not have a representative present during the inspection.

The site ID sign, E&S plan and weekly inspection reports were all on site and available for review during the inspection. The site was well vegetated and no E&S issues observed. The site does not have PCSM BMPs installed.

There were two wells that were in production phase during the inspection. No bubbling was observed in the well cellars. The Department also observed two production tanks and two GPU’s on the well pad. Specific conductivity readings were taken from puddles on the well pad surface. All puddles had specific conductivity readings below 275 µS/cm. The containment structure for the production tanks was observed and appeared to be in good condition.

2678909 Primary Facility 2018-01-03 Routine/Complete Inspection No Violations Noted On January 3, 2018, the Department conducted a routine inspection at the Chesapeake Appalachia LLC, Robinson Location in Orwell Township, Bradford County. Andrew Hobbins represented the Department. Nobody was present for Chesapeake.

The site sign, E & S plan and inspection logs were on site and available for review. The site was cover in a few inches of snow. The well pad has not been reduced, but PCSM was addressed by the installation of two infiltration berms.

Two wells were observed in production. The wells were labeled and no bubbling was observed in the well cellars. Two production tanks and two GPUs were also on site. All puddles on the pad were frozen. No staining was observed.

No violations were observed during the inspection.

2725244 Primary Facility 2018-05-02 Routine/Complete Inspection No Violations Noted Warm/breezy at time of inspection.

No annular vents present at time of inspection.

2772752 Primary Facility 2018-08-28 Site Restoration No Violations Noted NOT approval.

I took electrical conductivity readings from standing liquid on site with an Oakton PCSTestr 35. A puddle on the pad surface gave a 0.33 mS/cm reading. JLP

For data sources see[8]

References