If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-015-21341 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.730264,"lon":-76.330425,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Bradford | |
Municipality: Asylum Township | |
Operator Name: CHIEF OIL & GAS LLC | |
Well Pad ID: 147714 | |
Farm/Lease Name: ALLEN UNIT 1H | |
License Status: | |
Spud Date: | |
Permit Date: 2010-11-22 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: No | |
Latitude: 41.730264 | |
Longitude: -76.330425 |
Date | Event |
---|---|
2010-11-22 | New Permit Application |
2011-01-02 | Performed Spud Operation |
2011-09-22 | DEVIATED |
2011-11-05 | Perforation |
For data sources see[4]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2011-10-31 | 2011-10-31 | 6,222 | 6,116,460 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | Biocide - Bactron K 139 | Champion Technologies | Biocide | Glutaraldehyde | 111-30-8 | 0.05 | ||
Ethanol | 64-17-5 | |||||||
benzyl-C12-16 alkyldimethyl,chlorides | ||||||||
Quaternary ammonium compounds, benzyl-C12-16-alkyldimethyl, chlorides |
68424-85-1 | |||||||
FRW-300 | Frac Tech Services (FTS) | Friction Reducer | ||||||
Ethylene glycol | 107-21-1 | 0.08 | ||||||
Scale Inhibitor - Gyptron T-390 | Champion Technologies | Scale Inhibitor | Methanol | 67-56-1 | 0.01 | |||
Fresh Water | Base Fluid | Fresh Water | 100.00 | 85.79 | ||||
Sand (Proppant) | Frac Tech Services (FTS) | Propping Agent | Quartz | 14808-60-7 | 99.90 | 14.06 |
For data sources see[5]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2010 | CHIEF OIL & GAS LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2011 | CHIEF OIL & GAS LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2012 | CHIEF OIL & GAS LLC | 1,767,438.70 | 274 | 0.00 | 0 | 0.00 | 0 |
2013 | CHIEF OIL & GAS LLC | 2,445,161.00 | 345 | 0.00 | 0 | 0.00 | 0 |
2014 | CHIEF OIL & GAS LLC | 1,248,687.00 | 364 | 0.00 | 0 | 0.00 | 0 |
2015 | CHIEF OIL & GAS LLC | 866,085.00 | 325 | 0.00 | 0 | 0.00 | 0 |
2016 | CHIEF OIL & GAS LLC | 1,132,470.00 | 308 | 0.00 | 0 | 0.00 | 0 |
2017 | CHIEF OIL & GAS LLC | 1,150,262.78 | 365 | 0.00 | 0 | 0.00 | 0 |
2018 | CHIEF OIL & GAS LLC | 948,501.41 | 363 | 0.00 | 0 | 0.00 | 0 |
2019 | CHIEF OIL & GAS LLC | 823,015.78 | 364 | 0.00 | 0 | 0.00 | 0 |
For data sources see[6]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2010 | CHIEF OIL & GAS LLC | Fracing Fluid Waste | 2,530.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0091472 |
2011 | CHIEF OIL & GAS LLC | Fracing Fluid Waste | 5,500.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2012 | CHIEF OIL & GAS LLC | Fracing Fluid Waste | 3,236.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2012 | CHIEF OIL & GAS LLC | Produced Fluid | 2,455.50 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2013 | CHIEF OIL & GAS LLC | Produced Fluid | 5,103.70 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014 | CHIEF OIL & GAS LLC | Produced Fluid | 670.44 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2015 | CHIEF OIL & GAS LLC | Produced Fluid | 133.58 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016 | CHIEF OIL & GAS LLC | Produced Fluid | 481.20 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2017 | CHIEF OIL & GAS LLC | Waste comment only | 0.00 | ||
2017 | CHIEF OIL & GAS LLC | Produced Fluid | 286.06 Bbl | REUSE (AT WELL PAD) | |
2017 | CHIEF OIL & GAS LLC | Produced Fluid | 40.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123 |
2017 | CHIEF OIL & GAS LLC | Produced Fluid | 46.70 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2018 | CHIEF OIL & GAS LLC | Produced Fluid | 133.43 Bbl | REUSE (AT WELL PAD) | |
2019 | CHIEF OIL & GAS LLC | Produced Fluid | 165.27 Bbl | REUSE (AT WELL PAD) |
For data sources see[7]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
1952183 | Primary Facility | 2011-02-11 | Drilling/Alteration | No Violations Noted | Brandon. Set conductor with Zigenfus to 40'. Drilling with air to 5000' closed loop system. Drilled wells 1 and 2 with Zigenfus. Well #1 - no shows. Well #2 - showed 80 bbls of water that dried right up. |
1965593 | Primary Facility | 2011-04-14 | Routine/Complete Inspection | Violation(s) Noted | Bubbling between the 9 5/8 and 13 3/8 annuli. 8-10% combustible gas reading utilizing the MSA Model 60 gas meter. Uncontrolled release of gas. No well tag on wellhead. Iotopic sample obtained. |
1976892 | Primary Facility | 2011-05-10 | Routine/Complete Inspection | Outstanding Violations - No Viols Req'd | Methane vented to tank. No visible bubbling in cellar |
1983982 | Primary Facility | 2011-06-28 | Complaint Inspection | Violation(s) Noted | |
1985326 | Primary Facility | 2011-06-28 | Routine/Complete Inspection | Outstanding Violations - No Viols Req'd | Cellars filled with gravel. Condensate (methane) coming up thru gravel. |
1985800 | Primary Facility | 2011-07-04 | Follow-up Inspection | Outstanding Violations - No Viols Req'd | |
1987034 | Primary Facility | 2011-07-12 | Follow-up Inspection | No Violations Noted | |
1994975 | Primary Facility | 2011-08-09 | Follow-up Inspection | No Violations Noted | Faulty pressure gauge replaced. gauge now reads 0 psi on 9 5/8. |
2134260 | Primary Facility | 2013-01-29 | Complaint Inspection | No Violations Noted | Neighbor filed new water supply complaint, pad is closest and upgradient. |
2441060 | Primary Facility | 2016-01-14 | Routine/Complete Inspection | No Violations Noted | |
2502250 | Primary Facility | 2016-07-18 | Routine/Complete Inspection | No Violations Noted | |
2642333 | Primary Facility | 2017-10-02 | Routine/Complete Inspection | No Violations Noted | Three wells staged for production. Three separators within containment. No violations noted. |
2854544 | Primary Facility | 2019-03-13 | Routine/Complete Inspection | No Violations Noted | ALLEN WEL PAD. Chief representative Pat Adams "Well Tender" was leaving the site upon arrival and Randy Ferris "Optimization Specialist" arrived on the pad as the inspection was underway. Randy indicated the the Compressor unit had engine oil loss from the supply barrel within the shelter. The unit was staged on secondary containment at the time. The unit has been pressure washed and diminishing residual oil is collected on the secondary containment. Inspection of the perimeter near the compressor fan area and diversion ditch did not reveal any leaks from secondary containment. The site sign, drilling permits, weekly E&S reports, and emergency response plan were onsite for review. The E&S inspection log was reviewed; the last routine inspection was conducted on 03/04/19. PSCMs have been installed and are functioning as designed. No erosion issues were observed. The site is stab |
Inspection ID | Violation ID | Violation Date | Date Resolved | Violation Code | Violation Type | Violation Comments |
---|---|---|---|---|---|---|
1965593 | 608861 | 04/14/2011 | 2011-04-14 | 78.86* - Failure to report defective, insufficient, or improperly cemented casing w/in 24 hrs or submit plan to correct w/in 30 days | Administrative | |
1965593 | 608863 | 04/14/2011 | 2011-04-14 | 201TAG - Failure to install, in a permanent manner, the permit number on a completed well | Administrative | |
1983982 | 614410 | 06/28/2011 | 2011-06-28 | 78.66A - Failure to report release of substance threatening or causing pollution | Administrative | |
1983982 | 614414 | 06/28/2011 | 2011-06-28 | 402CSL - Failure to adopt pollution prevention measures required or prescribed by DEP by handling materials that create a danger of pollution. | Environmental Health & Safety |
For data sources see[8]