X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-015-21341

Well Details

Well ID: 37-015-21341
Loading map...
Country: United States
State: Pennsylvania
County: Bradford
Municipality: Asylum Township
Operator Name: CHIEF OIL & GAS LLC
Well Pad ID: 147714
Farm/Lease Name: ALLEN UNIT 1H
License Status:
Spud Date:
Permit Date: 2010-11-22
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.730264
Longitude: -76.330425

For data sources see[1][2][3]

Well History

Date Event
2010-11-22 New Permit Application
2011-01-02 Performed Spud Operation
2011-09-22 DEVIATED
2011-11-05 Perforation

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2011-10-31 2011-10-31 6,222 6,116,460

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Biocide - Bactron K 139 Champion Technologies Biocide Glutaraldehyde 111-30-8 0.05
Ethanol 64-17-5
benzyl-C12-16 alkyldimethyl,chlorides
Quaternary ammonium compounds,
benzyl-C12-16-alkyldimethyl, chlorides
68424-85-1
FRW-300 Frac Tech Services (FTS) Friction Reducer
Ethylene glycol 107-21-1 0.08
Scale Inhibitor - Gyptron T-390 Champion Technologies Scale Inhibitor Methanol 67-56-1 0.01
Fresh Water Base Fluid Fresh Water 100.00 85.79
Sand (Proppant) Frac Tech Services (FTS) Propping Agent Quartz 14808-60-7 99.90 14.06

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2010 CHIEF OIL & GAS LLC 0.00 0 0.00 0 0.00 0
2011 CHIEF OIL & GAS LLC 0.00 0 0.00 0 0.00 0
2012 CHIEF OIL & GAS LLC 1,767,438.70 274 0.00 0 0.00 0
2013 CHIEF OIL & GAS LLC 2,445,161.00 345 0.00 0 0.00 0
2014 CHIEF OIL & GAS LLC 1,248,687.00 364 0.00 0 0.00 0
2015 CHIEF OIL & GAS LLC 866,085.00 325 0.00 0 0.00 0
2016 CHIEF OIL & GAS LLC 1,132,470.00 308 0.00 0 0.00 0
2017 CHIEF OIL & GAS LLC 1,150,262.78 365 0.00 0 0.00 0
2018 CHIEF OIL & GAS LLC 948,501.41 363 0.00 0 0.00 0
2019 CHIEF OIL & GAS LLC 823,015.78 364 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2010 CHIEF OIL & GAS LLC Fracing Fluid Waste 2,530.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0091472
2011 CHIEF OIL & GAS LLC Fracing Fluid Waste 5,500.00 Bbl REUSE OTHER THAN ROAD SPREADING
2012 CHIEF OIL & GAS LLC Fracing Fluid Waste 3,236.00 Bbl REUSE OTHER THAN ROAD SPREADING
2012 CHIEF OIL & GAS LLC Produced Fluid 2,455.50 Bbl REUSE OTHER THAN ROAD SPREADING
2013 CHIEF OIL & GAS LLC Produced Fluid 5,103.70 Bbl REUSE OTHER THAN ROAD SPREADING
2014 CHIEF OIL & GAS LLC Produced Fluid 670.44 Bbl REUSE OTHER THAN ROAD SPREADING
2015 CHIEF OIL & GAS LLC Produced Fluid 133.58 Bbl REUSE OTHER THAN ROAD SPREADING
2016 CHIEF OIL & GAS LLC Produced Fluid 481.20 Bbl REUSE OTHER THAN ROAD SPREADING
2017 CHIEF OIL & GAS LLC Waste comment only 0.00
2017 CHIEF OIL & GAS LLC Produced Fluid 286.06 Bbl REUSE (AT WELL PAD)
2017 CHIEF OIL & GAS LLC Produced Fluid 40.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123
2017 CHIEF OIL & GAS LLC Produced Fluid 46.70 Bbl REUSE OTHER THAN ROAD SPREADING
2018 CHIEF OIL & GAS LLC Produced Fluid 133.43 Bbl REUSE (AT WELL PAD)
2019 CHIEF OIL & GAS LLC Produced Fluid 165.27 Bbl REUSE (AT WELL PAD)

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1952183 Primary Facility 2011-02-11 Drilling/Alteration No Violations Noted Brandon. Set conductor with Zigenfus to 40'. Drilling with air to 5000' closed loop system. Drilled wells 1 and 2 with Zigenfus. Well #1 - no shows. Well #2 - showed 80 bbls of water that dried right up.
1965593 Primary Facility 2011-04-14 Routine/Complete Inspection Violation(s) Noted Bubbling between the 9 5/8 and 13 3/8 annuli. 8-10% combustible gas reading utilizing the MSA Model 60 gas meter. Uncontrolled release of gas. No well tag on wellhead. Iotopic sample obtained.
1976892 Primary Facility 2011-05-10 Routine/Complete Inspection Outstanding Violations - No Viols Req'd Methane vented to tank. No visible bubbling in cellar
1983982 Primary Facility 2011-06-28 Complaint Inspection Violation(s) Noted
1985326 Primary Facility 2011-06-28 Routine/Complete Inspection Outstanding Violations - No Viols Req'd Cellars filled with gravel. Condensate (methane) coming up thru gravel.
1985800 Primary Facility 2011-07-04 Follow-up Inspection Outstanding Violations - No Viols Req'd
1987034 Primary Facility 2011-07-12 Follow-up Inspection No Violations Noted
1994975 Primary Facility 2011-08-09 Follow-up Inspection No Violations Noted Faulty pressure gauge replaced. gauge now reads 0 psi on 9 5/8.
2134260 Primary Facility 2013-01-29 Complaint Inspection No Violations Noted Neighbor filed new water supply complaint, pad is closest and upgradient.
2441060 Primary Facility 2016-01-14 Routine/Complete Inspection No Violations Noted
2502250 Primary Facility 2016-07-18 Routine/Complete Inspection No Violations Noted
2642333 Primary Facility 2017-10-02 Routine/Complete Inspection No Violations Noted Three wells staged for production. Three separators within containment. No violations noted.
2854544 Primary Facility 2019-03-13 Routine/Complete Inspection No Violations Noted ALLEN WEL PAD. Chief representative Pat Adams "Well Tender" was leaving the site upon arrival and Randy Ferris "Optimization Specialist" arrived on the pad as the inspection was underway. Randy indicated the the Compressor unit had engine oil loss from the supply barrel within the shelter. The unit was staged on secondary containment at the time. The unit has been pressure washed and diminishing residual oil is collected on the secondary containment. Inspection of the perimeter near the compressor fan area and diversion ditch did not reveal any leaks from secondary containment. The site sign, drilling permits, weekly E&S reports, and emergency response plan were onsite for review. The E&S inspection log was reviewed; the last routine inspection was conducted on 03/04/19. PSCMs have been installed and are functioning as designed. No erosion issues were observed. The site is stab

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
1965593 608861 04/14/2011 2011-04-14 78.86* - Failure to report defective, insufficient, or improperly cemented casing w/in 24 hrs or submit plan to correct w/in 30 days Administrative
1965593 608863 04/14/2011 2011-04-14 201TAG - Failure to install, in a permanent manner, the permit number on a completed well Administrative
1983982 614410 06/28/2011 2011-06-28 78.66A - Failure to report release of substance threatening or causing pollution Administrative
1983982 614414 06/28/2011 2011-06-28 402CSL - Failure to adopt pollution prevention measures required or prescribed by DEP by handling materials that create a danger of pollution. Environmental Health & Safety

For data sources see[8]