37-015-21343

Well Details

Well ID: 37-015-21343
Loading map...
Country: United States
State: Pennsylvania
County: Bradford
Municipality: Asylum Township
Operator Name: CHIEF OIL & GAS LLC
Well Pad ID: 147714
Farm/Lease Name: ALLEN UNIT 3H
License Status:
Spud Date:
Permit Date: 2010-11-22
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.730208
Longitude: -76.330506

For data sources see[1][2][3]

Well History

Date Event
2010-11-22 New Permit Application
2011-01-09 Performed Spud Operation
2011-07-26 Perforation
2011-09-14 DEVIATED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2011-07-25 2011-07-25 6,224 6,134,646

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Biocide - Bactron K 139 Champion Technologies Biocide
benzyl-C12-16 alkyldimethyl,chlorides
Quaternary ammonium compounds,
benzyl-C12-16-alkyldimethyl, chlorides
68424-85-1
Tetrahydro-3,5-dimethyl,2H-1,3,5-thiadiazine-2-thione 533-74-4 0.05
Ethanol 64-17-5
FRW-300W Frac Tech Services (FTS) Friction Reducer Ethylene glycol 107-21-1 0.07
Sand (Proppant) Frac Tech Services (FTS) Propping Agent Quartz 14808-60-7 99.90 12.64
Scale Inhibitor - Gyptron T-390 Champion Technologies Scale Inhibitor Methanol 67-56-1 0.01
Fresh Water Base Fluid Fresh Water 100.00 88.76
Fresh Water 100.00 87.21
Super Scale Control TSC Superior Well Services Scale Inhibitor
Anionic Polymer
1,2,4-Butanetricarboxylic acid, 2-phosphono- 37971-36-1
1,2-Propylene glycol 57-55-6 0.04
Anionic Copolymer
Sand (Proppant) Superior Well Services Propping Agent
Quartz 14808-60-7 99.90 11.06
KR-153SL Superior Well Services Biocide
Ethylene glycol 107-21-1 1.00
Polyethylene glycol 25322-68-3 50.00
Diethylene glycol 111-46-6
2,2-Dibromo-3-nitrilopropionamide 10222-01-2 20.00 0.02
WFR-3B Superior Well Services Friction Reducer 1,2-Propylene glycol 57-55-6 25.00
Ethoxylated C12-16 alcohols 68551-12-2 4.00
Distillates, petroleum, hydrotreated light 64742-47-8 0.08
Stoddard solvent 8052-41-3 10.00
CS 650 OS Frac Tech Services (FTS) Oxygen Scavenger
Ammonium bisulfite 10192-30-0 0.00700000
Nickel Chelate Catalyst 2.00
FE OXCLEAR Superior Well Services Oxygen Scavenger Ammonium bisulfite 10192-30-0 0.01

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2010 CHIEF OIL & GAS LLC 0.00 0 0.00 0 0.00 0
2011 CHIEF OIL & GAS LLC 0.00 0 0.00 0 0.00 0
2012 CHIEF OIL & GAS LLC 1,642,269.98 268 0.00 0 0.00 0
2013 CHIEF OIL & GAS LLC 1,783,679.00 361 0.00 0 0.00 0
2014 CHIEF OIL & GAS LLC 719,972.00 324 0.00 0 0.00 0
2015 CHIEF OIL & GAS LLC 510,423.00 341 0.00 0 0.00 0
2016 CHIEF OIL & GAS LLC 696,266.97 296 0.00 0 0.00 0
2017 CHIEF OIL & GAS LLC 738,069.77 365 0.00 0 0.00 0
2018 CHIEF OIL & GAS LLC 466,487.60 363 0.00 0 0.00 0
2019 CHIEF OIL & GAS LLC 402,981.39 364 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2011 CHIEF OIL & GAS LLC Fracing Fluid Waste 6,380.00 Bbl REUSE OTHER THAN ROAD SPREADING
2012 CHIEF OIL & GAS LLC Produced Fluid 2,965.10 Bbl REUSE OTHER THAN ROAD SPREADING
2012 CHIEF OIL & GAS LLC Fracing Fluid Waste 3,238.00 Bbl REUSE OTHER THAN ROAD SPREADING
2013 CHIEF OIL & GAS LLC Produced Fluid 2,902.50 Bbl REUSE OTHER THAN ROAD SPREADING
2014 CHIEF OIL & GAS LLC Produced Fluid 110.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC018
2014 CHIEF OIL & GAS LLC Produced Fluid 771.40 Bbl REUSE OTHER THAN ROAD SPREADING
2015 CHIEF OIL & GAS LLC Produced Fluid 157.20 Bbl REUSE OTHER THAN ROAD SPREADING
2016 CHIEF OIL & GAS LLC Produced Fluid 656.37 Bbl REUSE OTHER THAN ROAD SPREADING
2017 CHIEF OIL & GAS LLC Produced Fluid 40.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123
2017 CHIEF OIL & GAS LLC Produced Fluid 69.96 Bbl STORAGE PENDING DISPOSAL OR REUSE
2017 CHIEF OIL & GAS LLC Produced Fluid 205.31 Bbl REUSE (AT WELL PAD)
2019 CHIEF OIL & GAS LLC Produced Fluid 208.25 Bbl REUSE (AT WELL PAD)

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1965596 Primary Facility 2011-04-14 Routine/Complete Inspection Violation(s) Noted Well Drilled. Novisible bubbling. No well tag. 5 wells on location.
2041118 Primary Facility 2012-01-27 Follow-up Inspection No Violations Noted Responding to a call from Ralph Larsen, Chief Rep. While making connections to get the well on line producing(the well was shut in while they were working),they noticed some pressure on the 9 5/8" x 13 3/8" annulus. The welded plate had a pin hole at weld and was hissing. The annulus is now vented - open. Weld will be repaired, then I will investigate further.
2134263 Primary Facility 2013-01-29 Complaint Inspection No Violations Noted
2441039 Primary Facility 2015-01-14 Routine/Complete Inspection No Violations Noted
2502253 Primary Facility 2016-07-18 Routine/Complete Inspection No Violations Noted
2518914 Primary Facility 2016-09-13 Site Restoration No Violations Noted
2642338 Primary Facility 2017-10-02 Routine/Complete Inspection No Violations Noted Three wells staged for production. Three separators within containment. No violations noted.
2854548 Primary Facility 2019-03-13 Routine/Complete Inspection No Violations Noted ALLEN WEL PAD. Chief representative Pat Adams "Well Tender" was leaving the site upon arrival and Randy Ferris "Optimization Specialist" arrived on the pad as the inspection was underway. Randy indicated the the Compressor unit had engine oil loss from the supply barrel within the shelter. The unit was staged on secondary containment at the time. The unit has been pressure washed and diminishing residual oil is collected on the secondary containment. Inspection of the perimeter near the compressor fan area and diversion ditch did not reveal any leaks from secondary containment. The site sign, drilling permits, weekly E&S reports, and emergency response plan were onsite for review. The E&S inspection log was reviewed; the last routine inspection was conducted on 03/04/19. PSCMs have been installed and are functioning as designed. No erosion issues were observed. The site is stab

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
1965596 608867 04/14/2011 2011-04-14 201TAG - Failure to install, in a permanent manner, the permit number on a completed well Administrative

For data sources see[8]

References