X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-015-21426

Well Details

Well ID: 37-015-21426
Loading map...
Country: United States
State: Pennsylvania
County: Bradford
Municipality: Albany Township
Operator Name: CHIEF OIL & GAS LLC
Well Pad ID: 147538
Farm/Lease Name: CURTIN UNIT 1H
License Status:
Spud Date:
Permit Date: 2010-12-20
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.556636
Longitude: -76.403167

For data sources see[1][2][3]

Well History

Date Event
2010-12-20 New Permit Application
2011-02-14 Performed Spud Operation
2011-06-24 Perforation
2011-07-26 DEVIATED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2011-07-28 2011-07-28 8,306 5,293,176

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 FE OXCLEAR Superior Well Services Oxygen Scavenger Ammonium bisulfite 10192-30-0 0.01
Water Base Fluid Water 100.00 86.33
KR-153SL Superior Well Services Biocide 2,2-Dibromo-3-nitrilopropionamide 10222-01-2 20.00 0.02
Polyethylene glycol 25322-68-3 50.00
Diethylene glycol 111-46-6
Ethylene glycol 107-21-1 1.00
Sand (Proppant) Superior Well Services Propping Agent
Quartz 14808-60-7 99.90 13.49
Super Scale Control TSC Superior Well Services Scale Inhibitor 1,2-Propylene glycol 57-55-6 0.04
Anionic Polymer
Anionic Copolymer
1,2,4-Butanetricarboxylic acid, 2-phosphono- 37971-36-1
WFR-3B Superior Well Services Friction Reducer 1,2-Propylene glycol 57-55-6 25.00
Ethoxylated C12-16 alcohols 68551-12-2 4.00
Distillates, petroleum, hydrotreated light 64742-47-8 0.09
Stoddard solvent 8052-41-3 10.00

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2010 CHIEF OIL & GAS LLC 0.00 0 0.00 0 0.00 0
2011 CHIEF OIL & GAS LLC 0.00 0 0.00 0 0.00 0
2012 CHIEF OIL & GAS LLC 0.00 0 0.00 0 0.00 0
2013 CHIEF OIL & GAS LLC 2,295,647.00 196 0.00 0 0.00 0
2014 CHIEF OIL & GAS LLC 1,546,207.00 304 0.00 0 0.00 0
2015 CHIEF OIL & GAS LLC 1,226,901.40 316 0.00 0 0.00 0
2016 CHIEF OIL & GAS LLC 1,255,688.44 364 0.00 0 0.00 0
2017 CHIEF OIL & GAS LLC 1,075,435.80 365 0.00 0 0.00 0
2018 CHIEF OIL & GAS LLC 855,829.00 365 0.00 0 0.00 0
2019 CHIEF OIL & GAS LLC 808,167.16 365 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2011 CHIEF OIL & GAS LLC Fracing Fluid Waste 330.00 Bbl REUSE OTHER THAN ROAD SPREADING
2011 CHIEF OIL & GAS LLC Drill Cuttings 1,907.24 Tons LANDFILL 301626
2013 CHIEF OIL & GAS LLC Produced Fluid 1,929.90 Bbl REUSE OTHER THAN ROAD SPREADING
2014 CHIEF OIL & GAS LLC Produced Fluid 934.18 Bbl REUSE OTHER THAN ROAD SPREADING
2015 CHIEF OIL & GAS LLC Produced Fluid 1,838.22 Bbl REUSE OTHER THAN ROAD SPREADING
2016 CHIEF OIL & GAS LLC Produced Fluid 583.99 Bbl REUSE OTHER THAN ROAD SPREADING
2017 CHIEF OIL & GAS LLC Produced Fluid 26.83 Bbl STORAGE PENDING DISPOSAL OR REUSE
2017 CHIEF OIL & GAS LLC Produced Fluid 42.55 Bbl REUSE (AT WELL PAD)
2018 CHIEF OIL & GAS LLC Produced Fluid 238.79 Bbl REUSE (AT WELL PAD)
2019 CHIEF OIL & GAS LLC Produced Fluid 506.01 Bbl REUSE (AT WELL PAD)

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1963715 Primary Facility 2011-04-05 Follow-up Inspection Violation(s) Noted
1966483 Primary Facility 2011-04-13 Drilling/Alteration No Violations Noted cement job failure halliburton pump down, operator washed out cement pumped before bd and will resume when pump is fixed
1966486 Primary Facility 2011-04-14 Drilling/Alteration No Violations Noted failed cement job redone and completed 450sks 15.6 22bbls return
1971356 Primary Facility 2011-05-05 Drilling/Alteration No Violations Noted 9 5/8 set at 1832
1972493 Primary Facility 2011-05-12 Drilling/Alteration No Violations Noted 5 1/2 at12,894 1100sks 15#
1973182 Primary Facility 2011-05-12 Routine/Partial Inspection Violation(s) Noted
2000180 Primary Facility 2011-08-30 Follow-up Inspection No Violations Noted
2004898 Primary Facility 2011-09-15 Routine/Complete Inspection No Violations Noted well has been hydrofraced 450# on 5.5 x 9.72
2062450 Primary Facility 2012-04-20 Routine/Complete Inspection No Violations Noted 20" conductor is open, no bubbles.
2172170 Primary Facility 2013-06-04 Routine/Complete Inspection No Violations Noted
2248234 Primary Facility 2014-02-20 Routine/Partial Inspection No Violations Noted
2251104 Primary Facility 2014-03-05 Routine/Complete Inspection No Violations Noted
2255754 Primary Facility 2014-03-21 Routine/Complete Inspection No Violations Noted
2262628 Primary Facility 2014-04-09 Routine/Complete Inspection No Violations Noted There was no activity at the site during the inspection. According to an employee of DR Well Site Services LLC, Highlands Drilling Rig #8 recently moved off the location. The vertical section of the 2H and 3H wells has been drilled. Sidewinder Rig #258 will resume drilling procedures for the horizontal section of the 3H well at the location on 4/16/2014. The 1H well is in production. The drilling rig secondary containment system consisting of rig mats and a liner and a felt layer is still in place and apparently will be reused to drill the horizontal section of the well. There were some areas of compromised integrity in the liner, but overall the containment appeared to be in good condition. . There were no elevated conductivity readings of concern recorded on my meter during the inspection in water on and off containment.
2446553 Primary Facility 2016-02-03 Routine/Complete Inspection No Violations Noted
2495523 Primary Facility 2016-06-16 Routine/Complete Inspection No Violations Noted Routine inspection to assess overall site conditions. No Chief representatives were present. This inspection considered both the Curtin Well Site and the Curtin Freshwater Impoundment.

Vegetative cover on site is good, but is less than 70% in many areas. Temporary erosion and sediment control BMPs are in place. No eveidence of accelerated erosion or sedimentation was observed.

According to the Department's records, the Erosion and Sediment Control General Permit (ESCGP) for the Curtin Well Pad expired on 03/29/2016, an no current well permits exist for the site. The ESCGP for the Curtin Freshwater Impoundment expires on 11/25/2019. No request for a 2-year extension of time to restore the well site has been received by the Department. In order to remain in compliance with Title 58 Pa. C.S. § 3216 (2012 Oil and Gas Act), which relates to site restoration, a new well permit or a 2-year extension of time for site resotration should be obtained as soon as possible.

No violations were cited during this inspe

2503279 Primary Facility 2016-07-21 Routine/Complete Inspection No Violations Noted
2519541 Primary Facility 2016-09-13 Site Restoration No Violations Noted
2560028 Primary Facility 2017-02-06 Routine/Complete Inspection No Violations Noted Routine inspection to assess overall site conditions. Eric McClure of Chief was present. This inspection considered both the Curtin Well Site and the Curtin Freshwater Impoundment.

Vegetative cover on site is good, but is less than 70% in many areas due to extremely stony soil conditions. Temporary erosion and sediment control BMPs have been removed. No eveidence of accelerated erosion or sedimentation was observed.

During my inspection portions of the pad surface were being scraped in response to a release of diesel fuel that occurred over the weekend. The release occurred due to a leaking fuel tank in the back of a truck that was on site re-fuel equipment. It is estimated that approximatelyl 2-4 gallons of fuel were released on the pad surface and several locations along the access road. The pad surface was frozen except for the top 1/2-1 inch, so the release did not deeply infiltrate the pad substrate. At the juncture of the access road and State Route 220, however, Chief reports that gravel was remov

2697567 Primary Facility 2018-02-23 Routine/Complete Inspection No Violations Noted Three wells staged for production phase. Three water separators. No leaks detected from production equipment. No violations noted.

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
1963715 608256 04/05/2011 2011-04-05 102.4 - Failure to minimize accelerated erosion, implement E&S plan, maintain E&S controls. Failure to stabilize site until total site restoration under OGA Sec 206(c)(d) Environmental Health & Safety
1963715 608257 04/05/2011 2011-04-05 102.11 - Failure to design, implement or maintain BMPs to minimize the potential for accelerated erosion and sedimentation. Administrative
1963715 608258 04/05/2011 2011-04-05 401 CSL - Discharge of pollultional material to waters of Commonwealth. Environmental Health & Safety
1973182 611139 05/12/2011 2011-05-12 102.4 - Failure to minimize accelerated erosion, implement E&S plan, maintain E&S controls. Failure to stabilize site until total site restoration under OGA Sec 206(c)(d) Environmental Health & Safety

Penalties Applied

Violation ID Penalty ID Penalty Code Penalty Status Penalty Date Enforcement Date Penalty Amount Amount Collected
608256 269721 NOV - Notice of Violation Comply/Closed 2011-08-30
608257 269721 NOV - Notice of Violation Comply/Closed 2011-08-30
608258 269721 NOV - Notice of Violation Comply/Closed 2011-08-30

For data sources see[8]