If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-015-22076 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.679172,"lon":-76.675161,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Bradford | |
Municipality: Leroy Township | |
Operator Name: CHIEF OIL & GAS LLC | |
Well Pad ID: 146000 | |
Farm/Lease Name: YODER UNIT 1H | |
License Status: | |
Spud Date: | |
Permit Date: 2011-12-20 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: No | |
Latitude: 41.679172 | |
Longitude: -76.675161 |
Date | Event |
---|---|
2011-12-20 | New Permit Application |
2012-04-12 | Performed Spud Operation |
For data sources see[4]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2012-10-11 | 2012-10-11 | 7,138 | 4,751,628 | |
2 | 2012-07-02 | 2012-07-02 | 7,138 | 1,536,948 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | Fresh Water | Base Fluid | Fresh Water | 100.00 | 82.08 | |||
(J609) Schlumberge Friction Reducer Ammonium Sulfate 7783-20-2 10.0 - 30.0 r |
||||||||
0.09 | ||||||||
Biocide - Bactron K 139 | Champion Technologies | Biocide | Glutaraldehyde | 111-30-8 | 0.03 | |||
Ethanol | 64-17-5 | |||||||
Quaternary ammonium compounds, benzyl-C12-16-alkyldimethyl, chlorides |
68424-85-1 | |||||||
benzyl-C12-16 alkyldimethyl,chlorides | ||||||||
Sand (Proppant) | Schlumberger | Propping Agent | ||||||
Quartz | 14808-60-7 | 99.90 | 17.79 | |||||
(J609) Schlumberge Friction Reducer Ammonium Sulfate 7783-20-2 10.0 - 30.0 r |
Champion Technologies | Biocide | ||||||
Scale Inhibitor - Gyptron T-390 | Champion Technologies | Scale Inhibitor | Methanol | 67-56-1 | 0.00900000 | |||
2 | Scale Inhibitor - Gyptron T-390 | Champion Technologies | Scale Inhibitor | |||||
Methanol | 67-56-1 | 0.01 | ||||||
Hydrochloric Acid 15 | Frac Tech Services (FTS) | Acid | Water | 7732-18-5 | ||||
Hydrochloric acid | 7647-01-0 | 0.39 | ||||||
Fresh Water | Base Fluid | Fresh Water | 100.00 | 84.00 | ||||
FRW-600 | Frac Tech Services (FTS) | Friction Reducer | Distillates, petroleum, hydrotreated light | 64742-47-8 | 0.10 | |||
Sand (Proppant) | Frac Tech Services (FTS) | Propping Agent | ||||||
Quartz | 14808-60-7 | 99.90 | 15.43 | |||||
Biocide - Bactron K 139 | Champion Technologies | Biocide | ||||||
Ethanol | 64-17-5 | |||||||
Quaternary ammonium compounds, benzyl-C12-16-alkyldimethyl, chlorides |
68424-85-1 | |||||||
benzyl-C12-16 alkyldimethyl,chlorides | ||||||||
Glutaraldehyde | 111-30-8 | 0.06 |
For data sources see[5]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2011 | CHIEF OIL & GAS LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2012 | CHIEF OIL & GAS LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2013 | CHIEF OIL & GAS LLC | 1,670,494.00 | 254 | 0.00 | 0 | 0.00 | 0 |
2014 | CHIEF OIL & GAS LLC | 1,469,824.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2015 | CHIEF OIL & GAS LLC | 802,275.51 | 340 | 0.00 | 0 | 0.00 | 0 |
2016 | CHIEF OIL & GAS LLC | 731,348.76 | 365 | 0.00 | 0 | 0.00 | 0 |
2017 | CHIEF OIL & GAS LLC | 481,176.21 | 271 | 0.00 | 0 | 0.00 | 0 |
2018 | CHIEF OIL & GAS LLC | 605,645.15 | 363 | 0.00 | 0 | 0.00 | 0 |
2019 | CHIEF OIL & GAS LLC | 398,532.63 | 365 | 0.00 | 0 | 0.00 | 0 |
For data sources see[6]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2012 | CHIEF OIL & GAS LLC | Drill Cuttings | 1,556.04 Tons | LANDFILL | 301358 |
2012 | CHIEF OIL & GAS LLC | Fracing Fluid Waste | 2,015.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2012 | CHIEF OIL & GAS LLC | Drill Cuttings | 15.57 Tons | LANDFILL | 100933 |
2013 | CHIEF OIL & GAS LLC | Produced Fluid | 114.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123SW018 |
2013 | CHIEF OIL & GAS LLC | Produced Fluid | 10,067.50 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014 | CHIEF OIL & GAS LLC | Produced Fluid | 3,082.80 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014 | CHIEF OIL & GAS LLC | Fracing Fluid Waste | 110.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR119 |
2015 | CHIEF OIL & GAS LLC | Produced Fluid | 406.12 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016 | CHIEF OIL & GAS LLC | Produced Fluid | 1,005.41 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2017 | CHIEF OIL & GAS LLC | Produced Fluid | 471.93 Bbl | REUSE (AT WELL PAD) | |
2017 | CHIEF OIL & GAS LLC | Produced Fluid | 18.46 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2018 | CHIEF OIL & GAS LLC | Soil Contaminated by Oil | 28.50 Tons | LANDFILL | 301358 |
2018 | CHIEF OIL & GAS LLC | Soil Contaminated by Oil & Gas Related Spills | 28.50 Tons | LANDFILL | 301358 |
2018 | CHIEF OIL & GAS LLC | Produced Fluid | 1,007.20 Bbl | REUSE (AT WELL PAD) | |
2019 | CHIEF OIL & GAS LLC | Produced Fluid | 161.11 Bbl | REUSE (AT WELL PAD) |
For data sources see[7]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2041629 | Primary Facility | 2012-02-08 | Routine/Complete Inspection | No Violations Noted | |
2062925 | Primary Facility | 2012-04-26 | Incident- Response to Accident or Event | Violation(s) Noted | |
2072760 | Primary Facility | 2012-05-20 | Drilling/Alteration | No Violations Noted | |
2072762 | Primary Facility | 2012-05-23 | Drilling/Alteration | No Violations Noted | |
2081137 | Primary Facility | 2012-07-05 | Incident- Response to Accident or Event | Violation(s) Noted | |
2086563 | Primary Facility | 2012-07-26 | Routine/Complete Inspection | Outstanding Violations - No Viols Req'd | |
2089730 | Primary Facility | 2012-08-07 | Routine/Complete Inspection | Outstanding Violations - No Viols Req'd | |
2097401 | Primary Facility | 2012-09-05 | Routine/Complete Inspection | No Violations Noted | |
2100730 | Primary Facility | 2012-09-18 | Routine/Complete Inspection | No Violations Noted | |
2120407 | Primary Facility | 2012-10-16 | Incident- Response to Accident or Event | Viol(s) Noted & Immediately Corrected | |
2341171 | Primary Facility | 2015-01-30 | Routine/Partial Inspection | No Violations Noted | |
2556407 | Primary Facility | 2017-01-30 | Routine/Complete Inspection | No Violations Noted | One well in production phase. One water separator within steel containment. No leaks detected from production equipment at this time. Silt sock on top of tarp material surrounding quarter of pad. The DEP will request inspection documents related to the corroded production tank. This request is in accordance with PA code Chapter 25, 78a.57. Control, Storage and disposal of production fluids.
" (i) Tanks storing brine or other fluids produced during operation of the well shall be inspected by the operator at least once per calendar month and documented. Deficiencies noted during the inspection shall be addressed and remedied. When substantial modifications are necessary to correct deficiencies, they shall be made in accordance with manufacturer's specifications and applicable engineering design criteria. Any deficiencies identified during the inspection shall be reported to the Department electronically through its web site within 3 days of the inspection and remedied prior to continued use of the tank. Insp |
2556870 | Primary Facility | 2017-01-31 | Routine/Complete Inspection | No Violations Noted | One well in production phase. One water separator within steel containment. No leaks detected from production equipment at this time. Silt sock on top of tarp material surrounding quarter of pad. The DEP will request inspection documents related to the corroded production tank. This request is in accordance with PA code Chapter 25, 78a.57. Control, Storage and disposal of production fluids. " (i) Tanks storing brine or other fluids produced during operation of the well shall be inspected by the operator at least once per calendar month and documented. Deficiencies noted during the inspection shall be addressed and remedied. When substantial modifications are necessary to correct deficiencies, they shall be made in accordance with manufacturera^€TMs specifications and applicable engineering design criteria. Any deficiencies identified during the inspection shall be reported to the Department electronically through its web site within 3 days of the inspection and remedied prior to continued use of the tank. In |
2581364 | Primary Facility | 2017-04-11 | Routine/Complete Inspection | No Violations Noted | One well in production phase. One separator within plastic lined containment. No leaks detected from production equipment. Production tank replaced. Site stable. No violations noted. |
2594932 | Primary Facility | 2017-05-16 | Routine/Complete Inspection | No Violations Noted | |
2616475 | Primary Facility | 2017-07-05 | Routine/Complete Inspection | No Violations Noted | Drilling of the 3H well will be complete tonight. The drill of the 2H will begin shortly thereafter. All substances within secondary containment. No leaks or spills detected. No violations. Precision Rig 569 on site. |
2649675 | Primary Facility | 2017-10-18 | Incident- Response to Accident or Event | Viol(s) Noted & Immediately Corrected | I arrived at the site in response to a spill notification received Tuesday 10/17 at 16:00 hrs. Chief reported that approximately 1 barrel of fracwater/brine with friction reducer was spilled to the pad when a valve cover failed on the missile. I met Justin Myers and Chris Marsh when I was on-site. We looked at the area where the spill had occurred, and they informed me that Kellon Balum of Chief arrived soon after the spill and stopped the frac. They observed fluid coming out from under the liner, so Kellon had the equipment removed from the area, the containment pulled back, and immediately began removing the affected soil. Chris estimated that 2.5-3 cubic yards of soil had been removed, and pointed out the pile of soil on containment. Kellon assisted the excavation by screening the soil for TDS and had the excavation continue until the soil reached background levels (100-200 ppm). Once he determined that the release had been removed, he noted several holes in the liner that had been pulled back. Th |
2659876 | Primary Facility | 2017-11-09 | Routine/Complete Inspection | No Violations Noted | I met Floyd Roberts of Chief when I arrived. Workover rig on location to drill out plugs. Some small puddles were present in the area of the spill reported on 10/17; conductivity of these puddles was low (from .098 to .9 mS/cm). Some of the foam berms had been removed in antraffic area on the containment; although I didn't note any chemicals or waste in this area, I recommended to Floyd that he assess whether or not the berms should be put back in place. |
2676434 | Primary Facility | 2018-01-02 | Incident- Response to Accident or Event | Pending | Well is shut in due to a fire in one of the GPU units on 12/29/2017.
The GPU for the 2H and 3H wells were removed from the well pad as well as containment, to allow access to further investigate the fire. All wells on the pad were temp shut in at time of inspection. All annulus vents are vented to polly tank on location. |
Inspection ID | Violation ID | Violation Date | Date Resolved | Violation Code | Violation Type | Violation Comments |
---|---|---|---|---|---|---|
2062925 | 637971 | 04/26/2012 | 2012-04-26 | 78.54* - Failure to properly control or dispose of industrial or residual waste to prevent pollution of the waters of the Commonwealth. | Environmental Health & Safety | Diesel Fuel spill from Rig generator. |
2062925 | 638295 | 04/26/2012 | 2012-04-26 | CSL402POTPOL - There is a potential for polluting substance(s) reaching Waters of the Commonwealth and may require a permit | Environmental Health & Safety | |
2062925 | 638296 | 04/26/2012 | 2012-04-26 | SWMA301 - Failure to properly store, transport, process or dispose of a residual waste. | Environmental Health & Safety | |
2081137 | 643316 | 07/05/2012 | 2012-07-05 | 401 CSL - Discharge of pollultional material to waters of Commonwealth. | Environmental Health & Safety | 4700 gallons of HCL spilled. |
2081137 | 643317 | 07/05/2012 | 2012-07-05 | 301CSL - Stream discharge of IW, includes drill cuttings, oil, brine and/or silt | Environmental Health & Safety | 4700 gallons of HCL spilled. |
2081137 | 643318 | 07/05/2012 | 2012-07-05 | SWMA301 - Failure to properly store, transport, process or dispose of a residual waste. | Environmental Health & Safety | 4700 gallons of HCL spilled. |
2081137 | 643319 | 07/05/2012 | 2012-07-05 | 78.54* - Failure to properly control or dispose of industrial or residual waste to prevent pollution of the waters of the Commonwealth. | Environmental Health & Safety | 4700 gallons of HCL spilled. |
2081137 | 643320 | 07/05/2012 | 2012-07-05 | 307CSL - Discharge of industrial waste to waters of Commonwealth without a permit. | Environmental Health & Safety | 4700 gallons of HCL spilled. |
2120407 | 655013 | 10/16/2012 | 2012-10-16 | 78.54* - Failure to properly control or dispose of industrial or residual waste to prevent pollution of the waters of the Commonwealth. | Environmental Health & Safety | Spill of 420 gallons of re-use water. |
2120407 | 655014 | 10/16/2012 | 2012-10-16 | 402CSL - Failure to adopt pollution prevention measures required or prescribed by DEP by handling materials that create a danger of pollution. | Environmental Health & Safety | Spill of 420 gallons of reuse water. |
2649675 | 799550 | 2017-10-18 | 2017-10-18 | 78A57(A) | Environmental Health & Safety | Release of pollutional substance to pad surface |
2649675 | 799551 | 2017-10-18 | 2017-10-18 | SWMA 301 | Environmental Health & Safety | Release of pollutional substance to pad surface |
2649675 | 799552 | 2017-10-18 | 2017-10-18 | CSL 402(b) | Environmental Health & Safety | Release of pollutional substance to pad surface |
Violation ID | Penalty ID | Penalty Code | Penalty Status | Penalty Date | Enforcement Date | Penalty Amount | Amount Collected |
---|---|---|---|---|---|---|---|
637971 | 283344 | NOV - Notice of Violation | Comply/Closed | 2014-11-12 | |||
638295 | 283344 | NOV - Notice of Violation | Comply/Closed | 2014-11-12 | |||
638296 | 283344 | NOV - Notice of Violation | Comply/Closed | 2014-11-12 | |||
643316 | 285633 | NOV - Notice of Violation | Comply/Closed | 2015-01-30 | |||
643317 | 285633 | NOV - Notice of Violation | Comply/Closed | 2015-01-30 | |||
643318 | 285633 | NOV - Notice of Violation | Comply/Closed | 2015-01-30 | |||
643319 | 285633 | NOV - Notice of Violation | Comply/Closed | 2015-01-30 | |||
643320 | 285633 | NOV - Notice of Violation | Comply/Closed | 2015-01-30 |