If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-015-22158 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.811925,"lon":-76.279797,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Bradford | |
Municipality: Herrick Township | |
Operator Name: SWN PROD CO LLC | |
Well Pad ID: 147957 | |
Farm/Lease Name: CHILSON JENNINGS 3H | |
License Status: | |
Spud Date: | |
Permit Date: 2012-03-19 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: No | |
Latitude: 41.811925 | |
Longitude: -76.279797 |
Date | Event |
---|---|
2012-03-19 | New Permit Application |
2012-04-20 | Performed Spud Operation |
2013-02-06 | Perforation |
2014-05-06 | DEVIATED |
For data sources see[4]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2013-02-06 | 2013-02-06 | 6,398 | 7,186,662 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | ||||||||
Water Southwestern Water Water 7732-18-5 100.00 69.601464115217 |
||||||||
Super TSC LT | Nabors Industries | |||||||
KR-153SL | Services Company, USA | 2,2-dibromo-3-nitrilopropionamide | 20.00 | |||||
Water | 80.00 | |||||||
HCL Acid Nabors Bulk Acid Water 7732-18-5 87.50 25.9329180 |
||||||||
Acid Inhibitor 2 (AI-2) | Services Company, USA | |||||||
WFR-3B | Services Company, USA | |||||||
Super TSC LT | Proprietary | 15.00 | ||||||
WFR-3B | Hydrotreated light distillates, non-aromatic, | 50.00 | ||||||
Microparticle | 1.00 | |||||||
Ethoxylated oleylamine | 5.00 | |||||||
Propylene glycol | 15.00 | |||||||
Water | 40.00 | |||||||
Polyacrylamide | 40.00 | |||||||
BTEX free | ||||||||
Ethoxylated alcohols | 15.00 | |||||||
Acid Inhibitor 2 (AI-2) Nabors Acid Corrosion Inhibitors Glycol Ethers 111-46-6 20.00 0.011574000000 Completion and |
||||||||
Acid Inhibitor 2 (AI-2) | ||||||||
WFR-3B | Nabors Industries | |||||||
HCL Acid Nabors Bulk Acid Hydrogen Chloride 7647-01-0 18.00 5.334772000000 (12 |
||||||||
Acid Inhibitor 2 (AI-2) Nabors Acid Corrosion Inhibitors Propargyl Alcohol 107-19-7 20.00 0.011574000000 Completion and Pro |
||||||||
Acid Inhibitor 2 (AI-2) Nabors Acid Corrosion Inhibitors Isopropyl Alcohol 67-63-0 15.00 0.008681000000 Completion and Pr |
||||||||
Super TSC LT | Services Company, USA | |||||||
Acid Inhibitor 2 (AI-2) Nabors Acid Corrosion Inhibitors Ethoxylated Nonylphenol 68412-54-4 13.00 0.007523000000 Completion and Production Se |
||||||||
KR-153SL | Nabors Industries | |||||||
Acid Inhibitor 2 (AI-2) Nabors Acid Corrosion Inhibitors Tar bases, quinoline derivs, benzyl 72480-70-7 10.00 0.005787000000 |
||||||||
chloride-quaternized | ||||||||
Acid Inhibitor 2 (AI-2) | Nabors Industries | |||||||
Water | 40.00 | |||||||
KR-153SL |
For data sources see[5]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2012 | SOUTHWESTERN ENERGY PROD CO | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2013 | SOUTHWESTERN ENERGY PROD CO | 1,567,038.00 | 293 | 0.00 | 0 | 0.00 | 0 |
2014 | SOUTHWESTERN ENERGY PROD CO | 836,046.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2015 | SWN PROD CO LLC | 419,558.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2016 | SWN PROD CO LLC | 290,397.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2017 | SWN PROD CO LLC | 173,140.00 | 364 | 0.00 | 0 | 0.00 | 0 |
2018 | SWN PROD CO LLC | 125,148.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2019 | SWN PROD CO LLC | 142,788.00 | 365 | 0.00 | 0 | 0.00 | 0 |
For data sources see[6]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2012 | SOUTHWESTERN ENERGY PROD CO | Drill Cuttings | 1,644.19 Tons | LANDFILL | 101247 |
2013 | SOUTHWESTERN ENERGY PROD CO | Fracing Fluid Waste | 15,049.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2013 | SOUTHWESTERN ENERGY PROD CO | Drill Cuttings | 1,449.14 Tons | LANDFILL | 101247 |
2013 | SOUTHWESTERN ENERGY PROD CO | Produced Fluid | 15,043.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014 | SOUTHWESTERN ENERGY PROD CO | Produced Fluid | 3,420.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2015 | SWN PROD CO LLC | Produced Fluid | 140.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016 | SWN PROD CO LLC | Produced Fluid | 31.66 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC018 |
2016 | SWN PROD CO LLC | Fracturing Fluid Waste | 36.67 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016 | SWN PROD CO LLC | Produced Fluid | 61.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2017 | SWN PROD CO LLC | Other Oil & Gas Wastes | 63.33 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2017 | SWN PROD CO LLC | Produced Fluid | 488.33 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2017 | SWN PROD CO LLC | Other Oil & Gas Wastes | 17.33 Bbl | SURFACE IMPOUNDMENT | 826342 |
2018 | SWN PROD CO LLC | Produced Fluid | 150.00 Bbl | REUSE (AT WELL PAD) | |
2018 | SWN PROD CO LLC | Other Oil & Gas Wastes | 44.97 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2019 | SWN PROD CO LLC | Produced Fluid | 36.67 Bbl | SURFACE IMPOUNDMENT | 826342 |
2019 | SWN PROD CO LLC | Other Oil & Gas Wastes | 36.67 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
For data sources see[7]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2142794 | Primary Facility | 2013-01-24 | Routine/Complete Inspection | No Violations Noted | Well shut in. 9 x 5 and 5 1/2 = 0 psi. 1 seperator, 1 condensate tank. Cellar filled with wter, no visible bubbling. |
2144874 | Primary Facility | 2013-03-01 | Routine/Partial Inspection | No Violations Noted | Conductivity sampling of the pad surface revealed elevated levels of conductivity located at the puncture location. An Extech ExStik 2 meter revealed conductivity at a level of 9.8 milliSiemens/cm3, thus confirming that fluid did indeed flow through the puncture. Further sampling revealed conductivity levels dropping as moved away from this location. SWN is preparing to install new containment for flow back procedures. Instructed SWN to vacuum up the free standing water near and around the puncture location. Go ahead and place new containment down. Complete flow back procedures. Right after flow back procedures complete, remove containment, survey pad and identify the extent of the contamination, remove contaminated soil, conduct confirmatory sampling, etc. End result of clean up should at a minimum meet Act 2 requirements. Contact Department when excavation and sampling is to occur. Violations associated with this site being handled under inspection ID 2144808. |
2152056 | Primary Facility | 2013-03-21 | Routine/Complete Inspection | No Violations Noted | refer to inspection id 2152055 |
2159785 | Primary Facility | 2013-04-18 | Routine/Complete Inspection | No Violations Noted | |
2178680 | Primary Facility | 2013-06-27 | Administrative/File Review | No Violations Noted | refer to inspection ID # 2178678 |
2184238 | Primary Facility | 2013-07-11 | Routine/Complete Inspection | No Violations Noted | |
2189455 | Primary Facility | 2013-08-02 | Routine/Complete Inspection | Viol(s) Noted & Immediately Corrected | |
2196896 | Primary Facility | 2013-08-08 | Incident- Response to Accident or Event | No Violations Noted | |
2462114 | Primary Facility | 2016-03-03 | Routine/Complete Inspection | No Violations Noted | |
2538816 | Primary Facility | 2016-11-08 | Site Restoration | No Violations Noted | |
2656370 | Primary Facility | 2017-10-30 | Routine/Complete Inspection | No Violations Noted | On October 30, 2017, the Department conducted a routine inspection at the SWN Production Company, LLC, GU-Clark-Jennings-7-Pad in Herrick Township, Bradford County. Andrew Hobbins represented the Department. Nobody was present for SWN.
The site sign, E & S plan and weekly inspection logs were on site and available for review. The site was well vegetated and no erosion or sedimentation issues were observed. The well pad has not been reduced in size, and PCSM has not been addressed at the site. The Department recommends following the stipulations of the Consent Order & Agreement regarding site restoration. Three wells were in production during the inspection. The wells were labeled and no bubbling was observed. One production tank and three GPUs were on site. All conductivity readings taken from puddles on the pad were low in specific conductivity. No staining was observed on the surface of the well pad. No violations were observed during the inspection. |
2720336 | Primary Facility | 2018-04-19 | Routine/Complete Inspection | No Violations Noted | Three wells staged for production. No leaks detected. Site stable. No violations noted. |
2816555 | Primary Facility | 2018-12-17 | Site Restoration | No Violations Noted | The DEP conducted a RESTORATION inspection of SWN's Chilson Jennings (7 PAD) in Herrick Twp, Bradford County on 12/17/2018 at 1130 hours. The weather was cloudy and 37 degrees. The inspection was conducted in response to a well site restoration report received by the DEP.
This site currently has three wells in production with one production tank. The large portion to the west of the pad that includes the infiltration berm has recently been disturbed. The area is covered with hay/straw but 70% perennial vegetation has not been achieved. Also, temporary E&S BMPs (silt sock) was still in place to prevent erosional discharges. There is also a smaller portion along the access road with similar characteristics. This well site restoration report is considered returned at this time. Upon permanent stabilization and removal of temporary E&S BMPS and resubmission, the report could then be accepted. No violations noted today, I departed the site at 1200 hours. |
Inspection ID | Violation ID | Violation Date | Date Resolved | Violation Code | Violation Type | Violation Comments |
---|---|---|---|---|---|---|
2189455 | 674547 | 08/02/2013 | 2013-08-02 | 601.101 - O&G Act 223-General. Used only when a specific O&G Act code cannot be used | Administrative | Violation of Title 58 Pa.C.S. § 3218.2(d). Hydraulic fracturing additives stored in area without sufficient containment capacity. The pad liner where water with friction reducer, biocide and hydrate inhibitor was stored did not have a berm. |
For data sources see[8]