If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-015-23381 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.790364,"lon":-76.129175,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Bradford | |
Municipality: Stevens Township | |
Operator Name: SWN PROD CO LLC | |
Well Pad ID: | |
Farm/Lease Name: SEYMOUR 5H | |
License Status: | |
Spud Date: | |
Permit Date: 2017-12-15 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: No | |
Latitude: 41.790364 | |
Longitude: -76.129175 |
Date | Event |
---|---|
2017-12-15 | New Permit Application |
2019-01-04 | Permit Renewal Application |
For data sources see[4]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2675747 | Primary Facility | 2017-12-27 | Routine/Complete Inspection | No Violations Noted | On December 27, 2017, the Department conducted a routine inspection at the SWN Production Company LLC GU-X-Seymour-Pad in Stevens Township, Bradford County. Andrew Hobbins represented the Department. Nobody was present for SWN.
The site sign, E & S plan and weekly inspection logs were on site and available for review. The site has perennial vegetation starting to grow, but does not yet meet the 70% requirement. PCSM has been addressed with the recent installation of two infiltration berms. The berms and surrounding disturbed earth were temporarily stabilized with mulch and erosion control matting. The 1H and 3H wells were in production during the inspection. Both wells were labeled. The 2H and 4H wells had conductor casing set, but were not drilled to total depth. Liner and rig mats were installed around the well heads. One production tank and two GPUs were observed in secondary containment. Stormwater within the containment structures was observed to be frozen. All puddles on the pad were f |
2700484 | Primary Facility | 2018-02-20 | Incident- Response to Accident or Event | No Violations Noted | On February 20, 2018, the Department conducted an incident response inspection at the SWN Production Company LLC, GU-X-Seymour-Pad in Stevens Township, Bradford County. Andrew Hobbins, Water Quality Specialist, and Jon Sassi, Environmental Protection Specialist, represented the Department. Tommy Howard, well site supervisor, and Tracy Gregory, Regulatory Analyst, were on site for SWN. The Department was notified by Steve Moyer on February 18, 2018 that approximately 130 gallons of diesel spilled onto containment. A tear was found in the liner and diesel made its way under the liner and onto the surface of the pad. Mr. Moyer also noted that SWN had contracted Environmental Resource Recovery to remediate the spill.
The Department arrived on site at 1030 hrs. and observed 6 roll-off containers staged on secondary containment. Five containers contained contaminated soil, and one container was filled with liner material. The Department then observed the site of the spill. The excavation area was covere |
2718014 | Primary Facility | 2018-04-13 | Follow-up Inspection | No Violations Noted | Site being prepped for stimulation activities. Felt backed 30 mil liner being installed at his time. Water storage tank on location. No spills detected. Site stable. Residual clean-up operation remain for spilled diesel from February 2018 (insp 2696952). No issues detected. |