If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-019-21917 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.037703,"lon":-79.799133,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Butler | |
Municipality: Washington Township | |
Operator Name: CHEVRON APPALACHIA LLC | |
Well Pad ID: 146801 | |
Farm/Lease Name: HINDMAN UNIT 3H | |
License Status: Plugged and Abandoned | |
Spud Date: 2012-04-12 | |
Permit Date: 2011-12-15 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: Yes | |
Latitude: 41.037703 | |
Longitude: -79.799133 |
Date | Event |
---|---|
2011-12-15 | New Permit Application |
2012-04-12 | Performed Spud Operation |
2012-06-18 | Drilling Completion |
2018-05-04 | Begin Plugging |
2018-05-04 | Finished Plugging |
2018-09-07 | Fully Plugged |
For data sources see[4]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2012-12-13 | 2012-12-13 | 5,519 | 3,203,533 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | FR-66 Friction Reducer | Halliburton Energy Services | Friction Reducer | Distillates, petroleum, hydrotreated light | 64742-47-8 | 30.00 | 0.02 | |
7.5 Hcl Acid | Used to open perfs | Hydrochloric acid | 7647-01-0 | 7.50 | 0.30 | |||
WG-36 GELLING AGENT | Halliburton Energy Services | Water Viscosifier | Guar gum | 9000-30-0 | 100.00 | 0.00124000 | ||
Clean Volume (gals) | Carrier/Base Fluid | 90.87 | 100.00 | |||||
GBW-30 BREAKER | Halliburton Energy Services | Gel Breaker | Hemicellulase enzyme | 9012-54-8 | 15.00 | 0.00009000 | ||
Carbohydrates | 95.00 | 0.00055000 | ||||||
Biocide EC 6116A | Nalco | Biocide | Polyethylene glycol | 25322-68-3 | 60.00 | 0.01 | ||
2,2-Dibromo-3-nitrilopropionamide | 10222-01-2 | 30.00 | 0.00711000 | |||||
Dibromoacetonitrile | 3252-43-5 | 5.00 | 0.00118000 | |||||
EC6486A | Nalco | Scale Inhibitor | Ethylene glycol | 107-21-1 | 30.00 | 0.00711000 | ||
EC6673W | Nalco | Iron Control | Ethylene glycol | 107-21-1 | 30.00 | 0.00674000 | ||
ASP 900 | Nalco | Friction Reducer | Ammonium sulfate | 7783-20-2 | 30.00 | |||
Proppant (lbs) | Proppant | 9.13 | 10.12 |
For data sources see[5]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2011 | CHEVRON APPALACHIA LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2012 | CHEVRON APPALACHIA LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2013 | CHEVRON APPALACHIA LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2014 | CHEVRON APPALACHIA LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2015 | CHEVRON APPALACHIA LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2016 | CHEVRON APPALACHIA LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2017 | CHEVRON APPALACHIA LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
For data sources see[6]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2012 | CHEVRON APPALACHIA LLC | Drill Cuttings | 795.67 Tons | LANDFILL | 100172 |
2012 | CHEVRON APPALACHIA LLC | Drilling Fluid Waste | 5,409.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123SW001 |
2013 | CHEVRON APPALACHIA LLC | Fracing Fluid Waste | 43,636.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2013 | CHEVRON APPALACHIA LLC | Fracing Fluid Waste | 138.00 Bbl | INJECTION DISPOSAL WELL | 34-121-23995 |
2013 | CHEVRON APPALACHIA LLC | Produced Fluid | 138.00 Bbl | INJECTION DISPOSAL WELL | 34-121-23995 |
2013 | CHEVRON APPALACHIA LLC | Fracing Fluid Waste | 13,660.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123SW001 |
2014 | CHEVRON APPALACHIA LLC | Fracturing Fluid Waste | 91.02 Tons | STORAGE PENDING DISPOSAL OR REUSE | MID074259565 |
For data sources see[7]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2053113 | Primary Facility | 2012-03-22 | Drilling/Alteration | No Violations Noted | |
2060866 | Primary Facility | 2012-04-12 | Drilling/Alteration | No Violations Noted | |
2061960 | Primary Facility | 2012-04-18 | Drilling/Alteration | No Violations Noted | |
2064086 | Primary Facility | 2012-05-01 | Drilling/Alteration | No Violations Noted | |
2068147 | Primary Facility | 2012-05-10 | Routine/Partial Inspection | No Violations Noted | |
2076155 | Primary Facility | 2012-06-13 | Drilling/Alteration | No Violations Noted | |
2139616 | Primary Facility | 2013-02-13 | Routine/Partial Inspection | No Violations Noted | |
2154790 | Primary Facility | 2013-04-05 | Routine/Partial Inspection | No Violations Noted | |
2157406 | Primary Facility | 2013-04-15 | Administrative/File Review | No Violations Noted | |
2184541 | Primary Facility | 2013-07-11 | Routine/Partial Inspection | No Violations Noted | |
2185108 | Primary Facility | 2013-07-11 | Routine/Complete Inspection | No Violations Noted | |
2197010 | Primary Facility | 2013-08-15 | Routine/Partial Inspection | No Violations Noted | |
2215594 | Primary Facility | 2013-10-22 | Routine/Partial Inspection | No Violations Noted | |
2332998 | Primary Facility | 2014-12-30 | Site Restoration | No Violations Noted | |
2437132 | Primary Facility | 2015-12-30 | Routine/Partial Inspection | No Violations Noted | |
2690460 | Primary Facility | 2018-02-02 | Routine/Partial Inspection | No Violations Noted | On site for a routine partial inspection.
Well site has one drilled well. Well is on inactive status. Well head in place. No production equipment installed. No recent activity noted. Cattle guard installed around well head. Site stabilized with vegetation growth. All installed BMPs functioning properly. Act 13 sign installed. No well tag in place. The Department requests that a well tag with permit number be installed. |
2726775 | Primary Facility | 2018-05-04 | Plugging(Includes Plugged/Mined Through) | No Violations Noted | BJ cement equipment onsite. Cudd Energy Services crane equipment on site. Coil tubing rig on way to site and expect to be rigged up and pumping cement at 2PM.
Plan to tag bridge plug and spot cement 200' above plug using 391 sks of cement. |
2727662 | Primary Facility | 2018-05-07 | Plugging(Includes Plugged/Mined Through) | No Violations Noted | At the time of inspection, no activity was taking place at the site. Containment remains on the pad and secondary containment (with berms) surrounded the wellhead. The top of water can be seen in the well through what remains of the wellhead. It would be near ground level. Some of the cement covered the well from overflow and pea gravel was noticed in the secondary containment. A BJ Services cement truck is still onsite. 2 frac tanks and a open top tank are still on containment. The open top tank only has a few inches of freeboard remaining, if this has any contaminants in it, it could be considered a spill if it overflows. Please take care of this ASAP. |
2737088 | Primary Facility | 2018-06-04 | Administrative/File Review | No Violations Noted | |
2809296 | Primary Facility | 2018-11-28 | Site Restoration | No Violations Noted | On site for a site restoration inspection.
Operator submitted a Post-Plugging Well Site Restoration Report. Well is plugged with plugging marker buried. All BMPs have been restored. Site has been restored to approximate original contours. Noted sufficient vegetation growth. Snow coverage at time of inspection. |
For data sources see[8]