If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-021-20845 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.380103,"lon":-78.82926,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Cambria | |
Municipality: East Taylor Township | |
Operator Name: T & F EXPLORATION LP | |
Well Pad ID: | |
Farm/Lease Name: HELEN CASTINE 1 | |
License Status: ACTIVE | |
Spud Date: | |
Permit Date: 1993-08-16 | |
Well Type: GAS | |
Unconventional Well: N | |
Configuration: Vertical Well | |
Conservation: Yes | |
Latitude: 40.380103 | |
Longitude: -78.829260 |
Date | Event |
---|---|
1993-08-16 | New Permit Application |
1993-08-20 | Performed Spud Operation |
1993-09-01 | Drilling Completion |
1993-09-07 | Perforation |
1994-10-03 | NEWLY DRILLED |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
1995 | APPALACHIAN EXPLORATION CORP | 360046.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2009 | T & F EXPLORATION LP | 2464.00 | 182 | 0.00 | 0 | 0.00 | 0 |
2010 | T & F EXPLORATION LP | 4,584.00 | 335 | 0.00 | 0 | 0.00 | 0 |
2011 | T & F EXPLORATION LP | 9,616.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2012 | T & F EXPLORATION LP | 6,205.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2013 | T & F EXPLORATION LP | 6,562.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2014 | T & F EXPLORATION LP | 8,775.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2015 | T & F EXPLORATION LP | 5,788.00 | 276 | 0.00 | 0 | 0.00 | 0 |
2016 | T & F EXPLORATION LP | 8,400.00 | 335 | 0.00 | 0 | 0.00 | 0 |
2017 | T & F EXPLORATION LP | 3,112.00 | 335 | 0.00 | 0 | 0.00 | 0 |
2018 | T & F EXPLORATION LP | 2,715.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2019 | T & F EXPLORATION LP | 1,221.00 | 243 | 0.00 | 0 | 0.00 | 0 |
For data sources see[5]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|
For data sources see[6]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
1814882 | Primary Facility | 2009-07-17 | Routine/Complete Inspection | No Violations Noted | According to records, well was completed on 9/1/93 and WELLR submitted on 8/31/94. Well completed to a depth of 8430 ft. Well site was properly identified. No visible E&S concerns at the time of inspection. No IW discharge issues. Well head completed with 36", 13" and 4" flange with 5 gate valves. Well head pressure at 900 psi at well pad. Dual pen showing 250 psi/0 psi on data logger. Blue pen missing from dual pen system. Site last inspected on 7/1/09. Inlet line into brine tank showing signs of detoriation. |
2002042 | Primary Facility | 2011-08-30 | Routine/Complete Inspection | No Violations Noted | According to records, well was completed on 9/1/93 and WELLR submitted on 8/31/94. Well completed to a depth of 8430 ft. Well site was properly identified. No visible E&S concerns at the time of inspection. No IW discharge issues. . Separator pressure at 450 psi. Two -100 bbl brine tanks present with a total of 100 bbl of fluid. |
2006176 | Primary Facility | 2011-08-28 | Routine/Complete Inspection | No Violations Noted | According to records, well was completed on 9/1/93. Well completion report was submitted on 8/31/94. Well completed to a depth of 8430 ft. Well site was properly identified. No visible E&S concerns at the time of inspection. No IW discharge issues. Separator pressure showed a pressure of 450 psi. Two -100 bbl brine tanks were present with a total of 100 bbl of fluid. |
2093079 | Primary Facility | 2012-06-07 | Routine/Complete Inspection | No Violations Noted | At the time of inspection, no E&S and IW issues. Gas well was in production. |
2143530 | Primary Facility | 2013-02-05 | Routine/Complete Inspection | No Violations Noted | At the time of inspection, no E&S and IW issues. Gas well was in production. |
215519 | Primary Facility | 1993-08-27 | Drilling/Alteration | No Violations Noted | AT 2733'; E&S, PIT OK |
215538 | Primary Facility | 1993-08-31 | Drilling/Alteration | No Violations Noted | AT 7922'; E&S, PITS OK |
215554 | Primary Facility | 1993-09-09 | Routine/Complete Inspection | No Violations Noted | DRILLED; E&S, PIT OK |
215556 | Primary Facility | 1993-09-02 | Routine/Complete Inspection | Violation(s) Noted | INSUFF. CASING;E&S, PITS OK |
216373 | Primary Facility | 1994-12-07 | Routine/Complete Inspection | Violation(s) Noted | OUTSLOPE EROSION |
216598 | Primary Facility | 1995-03-13 | Routine/Complete Inspection | No Violations Noted | E&S OK; TANK |
2237758 | Primary Facility | 2014-01-16 | Routine/Complete Inspection | No Violations Noted | At the time of inspection, no E&S and IW issues. Gas well was in production. |
2321394 | Primary Facility | 2014-10-16 | Routine/Complete Inspection | No Violations Noted | At the time of inspection, no E&S and IW issues. Gas well was in production. |
2337798 | Primary Facility | 2015-01-22 | Routine/Complete Inspection | No Violations Noted | At the time of inspection, no E&S and IW issues. Gas well was in production. No signs of leakages from well head and production equipment located at the site. |
2341888 | Primary Facility | 2015-01-23 | Routine/Complete Inspection | No Violations Noted | On 1/22/15, DEP met with Ken Lecker from TF Exploration relative to natural gas odors occurring along the supply line from Castine well to meter box. Odors were reported to East Taylor police and fire department on January 20, 2015. Currently, well is not supplying gas and is currently shut in. The line is under 320 psi pressure. TF ran a pressure test on the line. However, the line is 17,000 feet long. Well is currently not supplying any gas to the supply line. On 1/23/15, Ken Lecker called and pressure held for 24 hr test. No odors were recorded at knock out pot located at breast of dam and behind the residential houses. Gas was left in line under pressure. |
2341912 | Primary Facility | 2015-01-24 | Routine/Complete Inspection | No Violations Noted | On 1/24/15, DEP received a telephone message relative to natural gas odors along Mineral Point Road near residents near the breast of the dam from Tom Gleason. He stated the odors were strong in the evening of 1/23/15. DEP performed an inspection at 11:00 hrs. on January 24th (Saturday). No odor was recorded near the residents. Area has no public supply of natural gas. DEP parked behind residence at 376 Mineral Point and walked the access road to the dam. No odor was recorded on the up gradient side hill side and near dam. DEP located the above ground supply line along the down gradient side of the access road. A slight odor was noted where the supply line was located underground at the access road. The slight odor was reported to T&F Exploration. No odor was reported inside of any structures. |
2341933 | Primary Facility | 2015-02-02 | Routine/Complete Inspection | No Violations Noted | On 1/26/15, DEP met with T&F exploration relative to odor complaint. The supply line was installed above ground as per request of the Water Authority and was moved due to new water lines installed in the area. The line was inspected from knock out tank to the upper access road located on top of the hillside. No leaks were recorded. The line was inspected along the upper access road. A slight odor was noted where the line trends from underground to the aboveground at the access road. On January 27th, East Taylor fire department received a call of natural odors along Mineral Point Road. DEP called T&F Exploration and requested to drain the supply line located near the resident houses. On January 28th, T&F vented the supply line at the well head. To date, no complaint of odor has been recorded. DEP inspected the line and no odor was recorded. |
2352774 | Primary Facility | 2015-03-17 | Routine/Complete Inspection | No Violations Noted | On 3/17/15, the lateral gas line was uncovered at the access dam road. A section of steel line was pressure tested and it was determined that a hole was located in the section of pipe. The underground section was replaced with a poly section of pipe. Underneath the access road, a secondary outer pipe was installed to protect section of gas line. The line was going to be tested again and well line was going to be placed back online |
2478093 | Primary Facility | 2016-04-25 | Routine/Complete Inspection | No Violations Noted | system running no issues |
2518568 | Primary Facility | 2016-09-06 | Routine/Complete Inspection | No Violations Noted | system running. no issues |
2532321 | Primary Facility | 2016-10-24 | Routine/Complete Inspection | No Violations Noted | well temporary shut in due to pressure relief valve on the line was opening/closing. system running. |
2549981 | Primary Facility | 2016-12-19 | Routine/Complete Inspection | No Violations Noted | system running. no issues |
2579250 | Primary Facility | 2017-02-02 | Routine/Complete Inspection | No Violations Noted | system running. no issues |
2585972 | Primary Facility | 2017-04-20 | Routine/Complete Inspection | No Violations Noted | Met Ken Lockard, T&F Exploration representative, at Dam breast where pressure relief valve was releasing gas. Valve is located on the gathering line near meter of Castine Well. Mr. Lockard shut in flow at well head so no gas was flowing through gathering line near meter box. A new relief valve was ordered and will be replaced |
2599148 | Primary Facility | 2017-05-24 | Routine/Complete Inspection | No Violations Noted | system running. no issues. |
2652753 | Primary Facility | 2017-10-26 | Routine/Complete Inspection | No Violations Noted | No issues. System was producing |
2673846 | Primary Facility | 2017-12-21 | Routine/Complete Inspection | No Violations Noted | System running. Well tag present. No issues |
2682869 | Primary Facility | 2018-01-17 | Routine/Complete Inspection | No Violations Noted | System running no issues. Well tag present. Emergency contact sign present. |
2706982 | Primary Facility | 2018-03-19 | Routine/Complete Inspection | No Violations Noted | Wellhead has well tag showing api number well name and emergency contact. Annulus open at well head. Production reporting up to date. |
2741456 | Primary Facility | 2018-06-14 | Routine/Complete Inspection | No Violations Noted | At time of inspection, gas well was in production. Nom issues at the site during inspection. Emergency contact and well tag were present. |
2753832 | Primary Facility | 2018-07-19 | Routine/Complete Inspection | No Violations Noted | Well in production. Well tag and emergency contact present at the site. No issues at the site. |
2828591 | Primary Facility | 2019-01-17 | Routine/Complete Inspection | No Violations Noted | Well is active. Production and MIA reports are update. Well tag present. No issues at the site |
Inspection ID | Violation ID | Violation Date | Date Resolved | Violation Code | Violation Type | Violation Comments |
---|---|---|---|---|---|---|
215556 | 103211 | 09/02/1993 | 1993-09-02 | 209CASING - Using inadequate casing | Environmental Health & Safety | INADEQUATE CASING |
216373 | 103693 | 12/07/1994 | 1994-12-07 | 102.4 - Failure to minimize accelerated erosion, implement E&S plan, maintain E&S controls. Failure to stabilize site until total site restoration under OGA Sec 206(c)(d) | Environmental Health & Safety | E&S MEASURES INADEQU |
Violation ID | Penalty ID | Penalty Code | Penalty Status | Penalty Date | Enforcement Date | Penalty Amount | Amount Collected |
---|---|---|---|---|---|---|---|
103211 | 16014 | NOV - Notice of Violation | Comply/Closed | 1994-08-22 | |||
103693 | 12360 | NOV - Notice of Violation | Comply/Closed | 1995-03-13 |
For data sources see[7]