X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-021-21142

Well Details

Well ID: 37-021-21142
Loading map...
Country: United States
State: Pennsylvania
County: Cambria
Municipality: Jackson Township
Operator Name: ALLIANCE PETRO CO LLC
Well Pad ID: 145932
Farm/Lease Name: MCCANN 1-M
License Status:
Spud Date:
Permit Date: 2009-08-25
Well Type: GAS
Unconventional Well: Y
Configuration: Vertical Well
Conservation: No
Latitude: 40.403318
Longitude: -78.874884

For data sources see[1][2][3]

Well History

Date Event
2009-08-25 New Permit Application
2009-10-28 Performed Spud Operation
2010-02-28 Drilling Completion
2010-03-10 Perforation
2010-09-23 NEWLY DRILLED

For data sources see[4]


Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2010 PDC MOUNTAINEER LLC 9,243.50 211 0.00 0 0.00 0
2011 PDC MOUNTAINEER LLC 20,146.00 353 0.00 0 0.00 0
2012 PDC MOUNTAINEER LLC 4,436.00 366 0.00 0 0.00 0
2013 PDC MOUNTAINEER LLC 4,007.01 365 0.01 181 0.01 181
2014 ALLIANCE PETRO CO LLC 3,769.00 359 0.00 0 0.00 0
2015 ALLIANCE PETRO CO LLC 2,735.40 334 0.00 0 0.00 0
2016 ALLIANCE PETRO CO LLC 2,352.00 326 0.00 0 0.00 0
2017 ALLIANCE PETRO CO LLC 1,918.00 357 0.00 0 0.00 0
2018 ALLIANCE PETRO CO LLC 1,829.00 363 0.00 0 0.00 0
2019 ALLIANCE PETRO CO LLC 1,006.00 360 0.00 0 0.00 0

For data sources see[5]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2010 PDC MOUNTAINEER LLC Fracing Fluid Waste 120.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0091472
2010 PDC MOUNTAINEER LLC Produced Fluid 689.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0095273
2011 PDC MOUNTAINEER LLC Produced Fluid 107.00 Bbl INJECTION DISPOSAL WELL 34-013-20611
2011 PDC MOUNTAINEER LLC Produced Fluid 118.00 Bbl INJECTION DISPOSAL WELL 34-059-24067
2012 PDC MOUNTAINEER LLC Produced Fluid 180.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0254185
2013 PDC MOUNTAINEER LLC Produced Fluid 460.00 Bbl CENT WASTE TRT FAC NPDES PA0254185
2013 PDC MOUNTAINEER LLC Produced Fluid 460.00 Bbl CENT WASTE TRT FAC NPDES DISCHARGE PA0254185
2014 ALLIANCE PETRO CO LLC Produced Fluid 180.00 Bbl STORAGE PENDING DISPOSAL OR REUSE
2014 ALLIANCE PETRO CO LLC Produced Fluid 180.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW005
2015 ALLIANCE PETRO CO LLC Produced Fluid 100.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW005
2015 ALLIANCE PETRO CO LLC Produced Fluid 95.00 Bbl STORAGE PENDING DISPOSAL OR REUSE
2016 ALLIANCE PETRO CO LLC Produced Fluid 365.00 Bbl INJECTION DISPOSAL WELL 2D0830792
2017 ALLIANCE PETRO CO LLC Produced Fluid 67.00 Bbl STORAGE PENDING DISPOSAL OR REUSE
2017 ALLIANCE PETRO CO LLC Produced Fluid 102.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW009
2018 ALLIANCE PETRO CO LLC Produced Fluid 215.00 Bbl INJECTION DISPOSAL WELL 34-007-21847
2018 ALLIANCE PETRO CO LLC Waste comment only 0.00
2019 ALLIANCE PETRO CO LLC Produced Fluid 100.00 Bbl INJECTION DISPOSAL WELL 34-007-21847
2019 ALLIANCE PETRO CO LLC Produced Fluid 100.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0254185

For data sources see[6]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1840930 Primary Facility 2009-11-02 Drilling/Alteration No Violations Noted Currently, site pad is in the process of completion. Inspected E&S plan and well sign located at entrance of site. Site design has been modified and initialized with changes. Filter fence and hay bails located along the perimeter of pad. Two pits dug at appropriate side wall ratio. Spud was called on 10/28/09 to the Williamsport DEP office. Conductor pipe has been set. Site has been seeded and straw covered surrounding the pad. According to PDC, rig will be starting on 11/16/09. Site located in high quality area. Well is going to be completed in the Marcellus. According to my conversation with Dave Hirko (Jackson twp manager), township was not notified of drilling event. DEP requested that PDC to contact township relative to ordinances (noise and work hours) and oil and gas township application. At the time of inspection, no E&S and IW issues. Adjacent properties have potable wells or springs as drinking water supplies.
1842252 Primary Facility 2009-11-04 Routine/Complete Inspection No Violations Noted At the time of inspection, the well was staked, not yet drilled. Contractors were actively excavating the well pad. The site was properly signed with E&S plan available for review. I noted that the site was in an HQ watershed; therefore, regulation requires the installation of increased/additional BMP¿s. A message was left with Jeff Clark on 11/10/09 discussing the additional BMP¿s. I observed the installation of filter fabric fence and culvert ditches. I am recommending that compost filter socks be utilized and/or additional BMP¿s with the filter fabric fence if it is not replaced. In addition, it is recommended that riprap be added to the culvert outlets/ditches until seeded vegetation produces growth. Disturbed areas and topsoil piles were temporarily seeded. Pits were constructed, but not yet lined. I am unsure of disposal method for drill cuttings; I plan to discuss this with PDC. No accelerated E&S issues were noted in relation to site or access road.
1844192 Primary Facility 2009-11-16 Drilling/Alteration No Violations Noted Currently, conduct pipe set at 40¿. 20 mil plastic aligned drilling pit and frac pit aligned also and security fence. Additional gravel added to entrance way. Township is concern with entrance way with gravel. Rig at 100 ft. First string is going to be set at for 1186¿ 13 3/8¿. At the time of inspection, no E&S and IW issues. Adjacent properties have potable wells or springs as drinking water supplies. Started drilling on 11/15/09
1845220 Primary Facility 2009-11-20 Drilling/Alteration No Violations Noted Currently, conduct pipe set at 40¿. 20 mil plastic aligned drilling pit and frac pit aligned also and security fence. No free board issues with pit. Additional fine gravel added to entrance way. Rig depth at 687 ft. First string is going to be set at 636 ft - 13 3/8¿ using 607 sks. With 60 bbl return. At the time of inspection, no E&S and IW issues. Barrier socks were set on down gradient of site pad. Filter fence and hay bails are also present.
1845498 Primary Facility 2009-11-24 Drilling/Alteration No Violations Noted Currently, conduct pipe set at 40¿. 20 mil plastic aligned drilling pit and frac pit aligned also and security fence. No free board issues with pit. Additional fine gravel added to entrance way. Rig progress at depth of 4385 ft. First string is going to be set at 636 ft - 13 3/8¿ using 607 sks. with 60 bbl return. Second string set at 1486 ft ¿ 8 5/8¿ pipe using 424 sks with 18 bbl returns. Small gas hits at 3892¿, 4052¿ and 4187¿. At the time of inspection, no E&S and IW issues. Rig shut down from 11/25/09 to 12/2/09 expected additional 5 to 7 working days of drilling.
1847634 Primary Facility 2009-12-03 Routine/Complete Inspection No Violations Noted At the time of inspection, the well was actively being drilled and site was properly signed with E&S plan available for review. Noted that both pits were lined and 2ft of freeboard was being maintained. I also noted the installation of compost sock down gradient form the site as well as filter fence reinforced with hay bales. No accelerated erosion or sedimentation issues were noted in relation to well site or access road. Access road was adequately rocked and also noted the addition of rock to culvert in/outlets. Recommend that operator continue to monitor access road and township roadways for mud and when necessary have a broom truck onsite to maintain roadways. I received a message from Ed Gahagn of PDC on 12/04/09 that he had plans to get a broom truck onsite to remove all mud/debris from township roadways. While onsite I talked to Miles Pierson (MPG Drilling), who noted the fact that drilling operations were commenced from 11/25/09 and returned on 12/2/09 for the holiday and they were expecting to be onsite several more days.
1847954 Primary Facility 2009-12-07 Routine/Complete Inspection No Violations Noted At the time of inspection, no E&S and IW issues. Pit aligned with 20 mil plastic aligned drilling pit and frac pit aligned also and security fence. No free board issues with pit. According to PDC, rig progress at depth of 8326 ft and anticipated depth should reached later part of day and followed by geophysical logging. At the time of inspection, no E&S and IW issues. Hydro frac of well has not been scheduled
1851675 Primary Facility 2009-12-22 Drilling/Alteration No Violations Noted At the time of inspection, no E&S and IW issues. Pit aligned with 20 mil plastic aligned drilling pit and frac pit aligned also and security fence. No free board issues with pit. According to PDC, rig will be shut down and removed from site due to problems with drilling operation with last 1500 ft of well. PDC will restart drilling operation in spring of 2010. McCutchen on-site to remove drilling fluids and remaining mud from site for disposal at facility. At the time of inspection, no E&S and IW issues.
1864822 Primary Facility 2010-02-22 Drilling/Alteration No Violations Noted At the time of inspection, no E&S and IW issues. Pit aligned with 20 mil plastic aligned drilling pit and frac pit aligned also and security fence. No free board issues with pit. Site is in the process of set up at 7900 ft and drill the last 1200 ft. According to Vaughn Staples (VBS), < 1 gallon of hydraulic fluid leak from drilling part. Spill was contained and absorbent pads were used along with hand digging of contaminant soil. Pads and soil were contained in drum. Additional pads were used around drilling part. At the time of inspection, no E&S and IW issues.
1867376 Primary Facility 2010-03-01 Drilling/Alteration No Violations Noted At the time of inspection, no E&S and IW issues. Pit aligned with 20 mil plastic aligned drilling pit and frac pit aligned also and security fence. No free board issues with pit. Well drilled to 8987 ft. TD. Schulumberger present to perform wire line study. BJ will be performing the cementing of last run. At the time of inspection, no E&S and IW issues.
1867377 Primary Facility 2010-03-02 Drilling/Alteration No Violations Noted At the time of inspection, no E&S and IW issues. Pit aligned with 20 mil plastic aligned drilling pit and frac pit aligned also and security fence. No free board issues with pit. Schulumberger completed wire line study. BJ completed cementing of last pipe string. well. Pipe in hole was 8969 ft. Cement used 339 sks of Type 1. Hole size was 7 7/8 inch. At the time of inspection, no E&S and IW issues.
1870229 Primary Facility 2010-03-15 Drilling/Alteration No Violations Noted At the time of inspection, no E&S and IW issues. Pit aligned with 20 mil plastic aligned drilling pit and frac pit aligned also and security fence. No free board issues with pit. Penn Energy present and performing back flow of hydro frac. Pressure on well head at 10 psi. Frac using frac pit as holding fresh water and flow back water is being stored in frac tanks. Roughly 10 frac tanks on-site. PDC vac truck removing fluid from drilling pit
1880298 Primary Facility 2010-04-27 Drilling/Alteration No Violations Noted At the time of inspection, no E&S and IW issues. Pit aligned with 20 mil plastic aligned drilling pit and frac pit aligned also and security fence. No free board issues with pit. Well connected production equipment. Swab rig was present at the wellhead. Heavy equipment was on-site to start restoring site and pits.
1896851 Primary Facility 2010-07-08 Routine/Complete Inspection No Violations Noted At the time of inspection, no E&S and IW issues. Site has been restored. Access road has been moved according to revised E&S plan. Well head consist of 13 x 8 x 4 x 2 inch piping with multiple shut offs. No signs of gas leakage around well head. Pressure at head consists of 620 psi casing, tubing 576 psi and 3306 MCF. Production equipment consists of tower, separator, compressor and 200 bbl tank (< 20 bbl fluid).
1900142 Primary Facility 2010-07-21 Routine/Complete Inspection No Violations Noted This is an ESCGP-1 site. At the time of inspection, well was drilled, properly signed, and in production. ESCGP-1, PPC, and E&S plan onsite. Operator notified department on 06/15/10 landing farming was to begin 06/18/10. Pits were successfully removed and site was regarded and seeded and mulched. Growth was observed, but not quite 70% uniform coverage. It is recommended that operate reseed some areas on pad that do not demonstrate successful growth in order to achieve uniform vegetative coverage. Brine tank surround by dike is stable. Access road was relocated around lower side of pad (disturbance area was not increased). Access road was stable, but over time it is recommended that operator add additional rock to prevent any erosion or sedimentation concerns that may arise. Operator should continue to maintain culvert outlets. Upon final restoration, filter fence may be removed. (a future inspection will be conducted to ensure adequate uniform coverage of previously disturbed areas). No IW issues were noted.
1915914 Primary Facility 2010-09-22 Site Restoration No Violations Noted ESCGP-1 site. At the time of inspection, well was drilled, properly signed, and in production. Drilling completed on 02/28/09. ESCGP-1, PPC, and E&S plan onsite. Pits were successfully removed (land farming of cuttings) and site was regarded and seeded and mulched with successful, uniform growth. Brine tank surround by dike appears sound, although noted discoloration along side of tank, but no dead vegetation was observed below or surrounding tank. Access road is relocated around lower side of pad (disturbance area was not increased). Access road appears stable, with adequately rocked culvert outlets. Operator should continue to maintain culvert outlets. Recommend that operator remove filter fence, as it appears site has be adequately and uniformly permanently restored. Also recommending that operator relocate and/or secure ALL chemicals onsite from third party access. No accelerated erosion or sedimentation issues were note din relation to well site or access road. Accompanied by WQS Dana Burk during inspection.
1941537 Primary Facility 2011-01-05 Drilling/Alteration No Violations Noted At the time of inspection, no E&S and IW issues. Site has been restored. Access road has been moved according to revised E&S plan. Well head consist of 13 x 8 x 4 x 2 inch piping with multiple shut offs. No signs of gas leakage around well head. Pressure at head consists of 300 psi casing, tubing . Production equipment consists of tower, separator, compressor and 200 bbl tank (< 20 bbl fluid).
1970680 Primary Facility 2011-04-20 Routine/Complete Inspection No Violations Noted At the time of inspection, no E&S and IW issues. Site has been restored. Access road has been moved according to revised E&S plan. Well head consist of 13 x 8 x 4 x 2 inch piping with multiple shut offs. No signs of gas leakage around well head. Pressure at head consists of 200 psi casing, tubing . Production equipment consists of tower, separator, compressor and 200 bbl tank (< 20 bbl fluid).
2016224 Primary Facility 2011-11-01 Routine/Complete Inspection No Violations Noted At the time of inspection, no E&S and IW issues. Pressure at wellhead was 250 psi. Production equipment consists of tower, separator, compressor and 200 bbl tank (< 20 bbl fluid). Meter showed a total flow of 17,597 MCF.
2024547 Primary Facility 2011-12-05 Routine/Complete Inspection No Violations Noted At the time of inspection, no E&S and IW issues. Pressure at wellhead was 300 psi. Production equipment consists of tower, separator, compressor and 200 bbl tank (< 20 bbl fluid). Meter showed a total flow of 103,411 MCF.
2067288 Primary Facility 2012-05-01 Routine/Complete Inspection No Violations Noted At the time of inspection, no E&S and IW issues. Gas well was in production.
2093073 Primary Facility 2012-06-07 Routine/Complete Inspection No Violations Noted At the time of inspection, no E&S and IW issues. Gas well was in production.
2093203 Primary Facility 2012-07-02 Routine/Complete Inspection No Violations Noted At the time of inspection, no E&S and IW issues. Gas well was in production.
2094836 Primary Facility 2012-08-24 Routine/Complete Inspection No Violations Noted At the time of inspection, no E&S and IW issues. Gas well was in production.
2123042 Primary Facility 2012-12-11 Routine/Complete Inspection No Violations Noted At the time of inspection, no E&S and IW issues. Gas well was in production.
2151609 Primary Facility 2013-03-20 Routine/Complete Inspection No Violations Noted At the time of inspection, no E&S and IW issues. Gas well was in production.
2198018 Primary Facility 2013-08-07 Routine/Complete Inspection No Violations Noted At time of inspection, well equipped for production. According to records, date of TD was 2/28/2010. Well tag present, legible.
2233812 Primary Facility 2014-01-02 Routine/Complete Inspection No Violations Noted At the time of inspection, no E&S and IW issues. Gas well was in production.
2237756 Primary Facility 2013-01-16 Routine/Complete Inspection No Violations Noted At the time of inspection, no E&S and IW issues. Gas well was in production
2247009 Primary Facility 2014-02-05 Routine/Complete Inspection No Violations Noted well in production
2271551 Primary Facility 2014-05-19 Complaint Inspection No Violations Noted operating w/ proper ID
2296075 Primary Facility 2014-07-14 Routine/Complete Inspection No Violations Noted At the time of inspection, no E&S issues were present at the site. Well was in production.
2306730 Primary Facility 2014-09-11 Routine/Complete Inspection No Violations Noted At the time of inspection, no E&S and IW issues. Gas well was in production.
2323951 Primary Facility 2014-11-20 Routine/Complete Inspection No Violations Noted At the time of inspection, no E&S and IW issues. Gas well was in production.
2342001 Primary Facility 2015-02-06 Routine/Complete Inspection No Violations Noted At the time of inspection, no E&S and IW issues. Gas well was in production.
2353619 Primary Facility 2014-03-05 Routine/Complete Inspection No Violations Noted At the time of inspection, no E&S and IW issues. Gas well was in production.
2372567 Primary Facility 2015-05-14 Routine/Complete Inspection No Violations Noted At the time of inspection, no E&S and IW issues. Gas well was in production
2437932 Primary Facility 2015-11-09 Routine/Complete Inspection No Violations Noted At the time of inspection, no E&S and IW issues. Gas well was in production
2455238 Primary Facility 2016-02-26 Routine/Complete Inspection No Violations Noted At the time of inspection, no E&S and IW issues. Gas well was in production
2473189 Primary Facility 2016-04-04 Routine/Complete Inspection No Violations Noted no issues. well in production
2478028 Primary Facility 2016-04-07 Routine/Complete Inspection No Violations Noted
2482798 Primary Facility 2016-05-05 Routine/Complete Inspection No Violations Noted system running no issues
2488855 Primary Facility 2016-05-26 Routine/Complete Inspection No Violations Noted system running. no issues
2518585 Primary Facility 2016-09-06 Routine/Complete Inspection No Violations Noted no issues. sysem running
2532307 Primary Facility 2016-10-18 Routine/Complete Inspection No Violations Noted system running. no issues
2538938 Primary Facility 2016-11-14 Routine/Complete Inspection No Violations Noted system running. no issues
2556988 Primary Facility 2017-01-25 Routine/Complete Inspection No Violations Noted system running. no issues
2579240 Primary Facility 2017-02-01 Routine/Complete Inspection No Violations Noted system running. no issues
2594477 Primary Facility 2017-04-26 Routine/Complete Inspection No Violations Noted system running. no issues
2605028 Primary Facility 2017-06-15 Routine/Complete Inspection No Violations Noted system running. no issues
2637125 Primary Facility 2017-09-18 Routine/Complete Inspection No Violations Noted
2668443 Primary Facility 2017-12-07 Routine/Complete Inspection No Violations Noted Well tag present. No issues at the site. Well producing.
2673606 Primary Facility 2017-12-20 Routine/Complete Inspection No Violations Noted System running no,issues
2682439 Primary Facility 2018-01-16 Routine/Complete Inspection No Violations Noted System running no issues. Well tag present. Emergency contact sign present.
2693318 Primary Facility 2018-02-12 Routine/Complete Inspection No Violations Noted System in production. Well tag and emergency numbers were present. No issues at the site
2699927 Primary Facility 2018-03-01 Routine/Complete Inspection No Violations Noted Well tag present and emergency contact information present. No issues at the site
2706431 Primary Facility 2018-03-16 Routine/Complete Inspection No Violations Noted Wellhead has well tag showing api number well name and emergency contact. Annulus open at well head. Production reporting up to date.
2716618 Primary Facility 2018-04-10 Routine/Complete Inspection No Violations Noted Well tag and emergency contact number present at the site. No issues at the site
2730852 Primary Facility 2018-05-17 Routine/Complete Inspection No Violations Noted At the time of inspection, well was in production. According to records, DEP did receive 2017 production reports. Emergency contact of APC and well tag were present. No issues at the site
2739681 Primary Facility 2018-06-11 Routine/Complete Inspection No Violations Noted At time of inspection, gas well was in production. Nom issues at the site during inspection. Emergency contact and well tag were present.
2752115 Primary Facility 2018-07-16 Routine/Complete Inspection No Violations Noted System in production. No issues
2753852 Primary Facility 2018-07-19 Routine/Complete Inspection No Violations Noted Well in production. Well tag and emergency contact present at the site. No issues at the site.
2762203 Primary Facility 2018-08-09 Routine/Complete Inspection No Violations Noted Well in production. No issues at the site.
2777405 Primary Facility 2018-09-20 Routine/Complete Inspection In Compliance with Policy Well appears equipped for production.
2809550 Primary Facility 2018-12-03 Routine/Complete Inspection No Violations Noted Well tag present. Well producing and no issues at site.
2846909 Primary Facility 2019-03-01 Routine/Complete Inspection No Violations Noted

For data sources see[7]

References