If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-021-21164 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.610231,"lon":-78.5868,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Cambria | |
Municipality: Clearfield Township | |
Operator Name: LPR ENERGY LLC | |
Well Pad ID: 146495 | |
Farm/Lease Name: SMITHMYER UNIT 1H | |
License Status: Inactive | |
Spud Date: 2011-05-11 | |
Permit Date: 2010-08-04 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: No | |
Latitude: 40.610231 | |
Longitude: -78.5868 |
Date | Event |
---|---|
DEVIATED | |
2010-08-04 | New Permit Application |
2011-05-11 | Performed Spud Operation |
2011-07-18 | Drilling Completion |
2019-03-15 | Inactive Well Request Granted |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2010 | CHIEF OIL & GAS LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2011 | CHEVRON APPALACHIA LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2012 | CHEVRON APPALACHIA LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2013 | CHEVRON APPALACHIA LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2014 | CHEVRON APPALACHIA LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2015 | LPR ENERGY LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2016 | LPR ENERGY LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2017 | LPR ENERGY LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2019 | LPR ENERGY LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
For data sources see[5]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2011 | CHIEF OIL & GAS LLC | Drilling Fluid Waste | 720.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | EPA ID: 748-163 |
2011 | CHIEF OIL & GAS LLC | Drill Cuttings | 194.71 Tons | LANDFILL | 101421 |
2011 | CHIEF OIL & GAS LLC | Drill Cuttings | 695.88 Tons | LANDFILL | 101534 |
For data sources see[6]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
1972639 | Primary Facility | 2011-05-13 | Routine/Complete Inspection | No Violations Noted | At the time of inspection, well sign (permit #), ES plan, and ESCGP-1 located onsite. Well spud 05/11/11. Access road stable. Rig located onsite actively drilling. Site secured by fence and 24hr security. Observed temporary (lined) containment pad located beneath rig in order to prevent/contain a possible pollution event. Temporary BMP¿s installed according to ES plan. All culverts, outlets, and sediment traps appear adequately rocked. No accelerated erosion/sedimentation or IW issues are noted. Operator should continue to routinely monitor/maintain all BMP¿S until final site restoration is achieved. All previously disturbed areas have been stabilized with vegetative blankets, with some growth observed. Soil pile has been temporarily seeded, minimal growth observed, although compost sox installed down gradient. No violations noted during this inspection. |
1975379 | Primary Facility | 2011-05-18 | Drilling/Alteration | No Violations Noted | At the time of inspection, no E&S or IW discharge issues at the site. Chief hired UDI rig. Dewayne Pauley is the company representative. Conductor pipe set at 69 ft using 20¿ pipe. First stringer set at 679 ft with 13 3/8¿ pipe using Gas block of 485 sacks with 15 bbl return. Second stringer was set at 1846 feet using 9 5/8¿ pipe with 585 sks and 15 bbl return. Current depth was at 2,300 feet. Pilot hole set for 9000 ft. E&S controls were in place. |
1986001 | Primary Facility | 2011-06-28 | Drilling/Alteration | No Violations Noted | At the time of inspection, no E&S or IW discharge issues at the site. Conductor pipe set at 69 ft using 20¿ pipe. First stringer set at 679 ft with 13 3/8¿ pipe using Gas block of 485 sacks with 15 bbl return. Second stringer was set at 1846 feet using 9 5/8¿ pipe with 585 sks and 15 bbl return. Current depth was at 9263 feet. Cement plug was set back to 8500 ft approximately 737 ft. and used 300 sks of Class A cement. Wire line Survey was completed of the well. Horizontal leg scheduled for 4699 feet. E&S controls were in place. |
1986053 | Primary Facility | 2011-06-01 | Drilling/Alteration | No Violations Noted | At the time of inspection, no E&S or IW discharge issues at the site. Chief hired UDI rig. Dewayne Pauley is the company representative. Conductor pipe set at 69 ft using 20¿ pipe. First stringer set at 679 ft with 13 3/8¿ pipe using Gas block of 485 sacks with 15 bbl return. Second stringer was set at 1846 feet using 9 5/8¿ pipe with 585 sks and 15 bbl return. Current depth was at 9250 feet. Bridge plug set at 1700 ft. with 10ft cement plug on top of plug. E&S controls were in place. |
1995968 | Primary Facility | 2011-08-16 | Complaint Inspection | No Violations Noted | Id sign at entrance. Drilling complete. No rig onsite. Well not yet equipped for production. E&S ok. |
1997496 | Primary Facility | 2011-08-16 | Routine/Complete Inspection | Viol(s) Noted & Immediately Corrected | Site visit was result of spill notification by Nick Staffieri of Chevron on August 13, 2011. |
2002450 | Primary Facility | 2011-09-13 | Complaint Inspection | No Violations Noted | Drilling complete. Id sign and e&s plan ok. No rig onsite. |
2003118 | Primary Facility | 2011-09-02 | Routine/Complete Inspection | No Violations Noted | At the time of inspection, well sign, ES plan, and ESCGP-1 present. Access road adequately rocked and stable. Site gated with 24 hr security onsite. Well drilled, not yet in production. BMPs installed and functioning properly. No accelerated erosion or sedimentation observed. Site has been temporarily seeded and mulched providing temporary stabilization. Five frac tanks located onsite, noted that one tank was left with a hose attached (Chevron Rep Nick Staffieri contacted). Observed that area of previously reported spill has been cleaned up, yet disturbed areas have not yet been restored as operator is awaiting final analysis results to confirm all contaminates have been removed. A follow up inspection will be conducted to ensure that previously impacted areas have been successful remediated. |
2040799 | Primary Facility | 2012-01-31 | Routine/Complete Inspection | No Violations Noted | At the time of inspection, no E&S issues were present at the site. Gas well was not in production. Chevron was called by DEP to change well sign from Chief to Chevron. |
2093223 | Primary Facility | 2012-07-18 | Routine/Complete Inspection | No Violations Noted | At the time of inspection, no E&S issues were present at the site. Gas well was not in production. |
2148481 | Primary Facility | 2013-03-07 | Routine/Complete Inspection | No Violations Noted | On-site meeting with Chevron rep Curtis Small. |
2223649 | Primary Facility | 2013-11-20 | Routine/Complete Inspection | No Violations Noted | Production equipment on site, though well not in production at time of inspection. Site surrounded by fence, gated off. Site ID located on access road. Pad is not vegetated and remains stone-covered. Production equipment and brine tank surrounded by gate. Tank is on lined secondary containment. Tank appears sound. Two stockpiles of stone on site. Well spudded on 5/11/13, granted inactive status on 6/08/12. Dept. spoke to two reps from Chevron who arrived on site during inspection. Discussed well history and plans for restoration work. No E&S issues observed and access road is in good condition. |
2266650 | Primary Facility | 2014-04-24 | Routine/Complete Inspection | No Violations Noted | On-site inspt in response to NOT submittal by Opr on 4/02/14 for ESX10-021-0002 (Smithmyer Well Pad).Site ID sign present, in compliance with Act 9 standards.ERP, E&S/PCSM plan, ESCGP-1 on-site.Site is stabilized w/uniform & adequate veg growth.AR in good condition.Current on-site conditions do not meet previously-approved PCSM plan.Components on-site that are not identified on PCSM plan include: a culvert pipe installed in the fill slope of the pad, a rock pile, & a pile of (what appears to be) absorbent materials.Dept spoke to Opr rep Nick Staffieri to inquire about these unidentified components & to recommend that PCSM BMPs are properly monitored & maintained (i.e. access road culverts & ditches).Mr. Staffieri agreed to investigate & subsequently respond to Dept's inquiries once sufficient answers can be provided.As the current PCSM plan does not reflect on-site conditions, this NOT is being denied at this time.Pending awaiting add'l info. |
2321577 | Primary Facility | 2014-11-13 | Routine/Complete Inspection | No Violations Noted | Marcellus. At time of inspection, well drilled, not yet frac'd. According to records, drilling occurred 5/11/2011-7/18/2011. Well granted inactive status on 6/8/2012. Well tag present. Brine tank on containment. |
2325389 | Primary Facility | 2014-12-01 | Routine/Complete Inspection | No Violations Noted | Marcellus. At time of inspection, well drilled, not yet frac'd. According to records, drilling occurred 5/11/2011-7/18/2011. Well granted inactive status on 6/8/2012. Well tag present. Poly tank on containment, appears sound. Well surrounded by gate. |
2334723 | Primary Facility | 2014-12-30 | Routine/Complete Inspection | No Violations Noted | Well is inactive. At the time of, no issues were recorded. |
2349913 | Primary Facility | 2015-03-04 | Complaint Inspection | No Violations Noted | At time of inspection, well is in regulatory inactive status, granted 6/8/2012. According to records, drilling occurred 5/11/2011-7/18/2011. Gate located around wellhead. |
2465384 | Primary Facility | 2016-03-16 | Routine/Complete Inspection | No Violations Noted | Well is inactive. At the time of, no issues were recorded. |
2549963 | Primary Facility | 2016-12-13 | Routine/Complete Inspection | No Violations Noted | No activity at site. well in inactive mode. |
2655276 | Primary Facility | 2017-11-01 | Routine/Complete Inspection | No Violations Noted | DEP personnel performed inspection of the site for inactive well status. Well is currently shut in pending pipeline construction. At the time of inspection, no issues at the site. Well meets all criteria for 78.102 regulation. |
2697826 | Primary Facility | 2018-02-23 | Routine/Complete Inspection | No Violations Noted | Well does not appear equipped for production. Well head surrounded by security fence.
According to Department's records DEP OGI conducted site inspection regarding inactive status on 11-01-17 and found operator in compliance. |
Inspection ID | Violation ID | Violation Date | Date Resolved | Violation Code | Violation Type | Violation Comments |
---|---|---|---|---|---|---|
1997496 | 618424 | 08/16/2011 | 2011-08-16 | 78.54* - Failure to properly control or dispose of industrial or residual waste to prevent pollution of the waters of the Commonwealth. | Environmental Health & Safety |
For data sources see[7]