If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-021-21171 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.617732,"lon":-78.739819,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Cambria | |
Municipality: West Carroll Township | |
Operator Name: SLA EXPLORATION LLC | |
Well Pad ID: | |
Farm/Lease Name: TERRIZZI SR 2 | |
License Status: | |
Spud Date: | |
Permit Date: 2010-12-30 | |
Well Type: GAS | |
Unconventional Well: N | |
Configuration: Vertical Well | |
Conservation: No | |
Latitude: 40.617732 | |
Longitude: -78.739819 |
Date | Event |
---|---|
2010-12-30 | New Permit Application |
2011-01-18 | Performed Spud Operation |
2011-01-26 | Drilling Completion |
2011-02-27 | Perforation |
2011-08-30 | NEWLY DRILLED |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2011 | NTS ENERGY LLC | 8,551.00 | 160 | 0.00 | 0 | 0.00 | 0 |
2012 | NTS ENERGY LLC | 5,049.00 | 131 | 0.00 | 0 | 0.00 | 0 |
2013 | NTS ENERGY LLC | 640.00 | 10 | 0.00 | 0 | 0.00 | 0 |
2014 | NTS ENERGY LLC | 3,660.00 | 150 | 0.00 | 0 | 0.00 | 0 |
2015 | NTS ENERGY LLC | 43,588.00 | 360 | 0.00 | 0 | 0.00 | 0 |
2016 | NTS ENERGY LLC | 2,266.00 | 90 | 0.00 | 0 | 0.00 | 0 |
2018 | SLA EXPLORATION LLC | 3,021.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2019 | HIGHPOINTE OIL & GAS LLC | 1,334.97 | 122 | 0.00 | 0 | 0.00 | 0 |
For data sources see[5]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2011 | NTS ENERGY LLC | Fracing Fluid Waste | 205.00 Bbl | CENT WASTE TRT FAC NPDES DISCHARGE | PA0101508 |
2011 | NTS ENERGY LLC | Fracing Fluid Waste | 322 Bbl | CENT WASTE TRT FAC NPDES | PA0095443 |
2011 | NTS ENERGY LLC | Fracing Fluid Waste | 322.00 Bbl | CENT WASTE TRT FAC NPDES DISCHARGE | PA0095443 |
2011 | NTS ENERGY LLC | Fracing Fluid Waste | 205 Bbl | CENT WASTE TRT FAC NPDES | PA0101508 |
2013 | NTS ENERGY LLC | Produced Fluid | 70.00 Bbl | CENT WASTE TRT FAC NPDES DISCHARGE | PA0095443 |
2013 | NTS ENERGY LLC | Produced Fluid | 60 Bbl | CENT WASTE TRT FAC NPDES | PA0095273 |
2013 | NTS ENERGY LLC | Produced Fluid | 60.00 Bbl | CENT WASTE TRT FAC NPDES DISCHARGE | PA0095273 |
2013 | NTS ENERGY LLC | Produced Fluid | 70 Bbl | CENT WASTE TRT FAC NPDES | PA0095443 |
2014 | NTS ENERGY LLC | Produced Fluid | 148.00 Bbl | CENT WASTE TRT FAC NPDES DISCHARGE | PA0095273 |
2014 | NTS ENERGY LLC | Produced Fluid | 148 Bbl | CENT WASTE TRT FAC NPDES | PA0095273 |
2018 | SLA EXPLORATION LLC | Produced Fluid | 40.00 Bbl | CENT WASTE TRT FAC NPDES DISCHARGE | PA0095273 |
For data sources see[6]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
1943822 | Primary Facility | 2011-01-19 | Drilling/Alteration | No Violations Noted | Well Id sign and E&S plan present at access road. At the time of inspcetion, no E&S or OW discharge issues at the site. Slight mud located on paved highway at entrance way. Talked to NTS Energy and stated that brush truck is mobilizing to site to clean the main road. Pit covered with 20 mil plastic and surrounded by security fence. Filter fence present on the down gradient side of site. Spud called on 11/17/11. Drilling started on 1-18-11. Conductor pipe installed to 17 ft. (20¿) pipe. Mine shaft located at 287 ft. to 291 ft. Current depth is 291 ft. Drill rig down due to bad injector. PC planning to drill to 330 ft and set mine string (13 5/8¿). As noted, possible 2nd mine shaft located at 400 ft. PC going to run 9 5/8¿ stringer. Anticipated depth is 3760¿. |
1944876 | Primary Facility | 2011-01-25 | Drilling/Alteration | No Violations Noted | Well Id sign and E&S plan present at access road. At the time of inspcetion, no E&S or OW discharge issues at the site. Pit covered with 20 mil plastic and surrounded by security fence. No freeboard issues. Filter fence present on the down gradient side of site. Conductor pipe installed to 17 ft. (20¿) pipe (sanded in). Site was drilled through the area of concern mine shaft. PC revised log to say no mine shaft was recorded but determine that the next 46 ft was collapsing ¿soft¿ rock. DEP inspector notified on 1/22/11 by NTS and PC to set a 13 3/8¿ pipe as a ¿2nd conductor to prevent well from collapsing. Pipe was set at 337 ft. The 9 5/8¿ pipe was installed at 392 ft with 225 sks class A cement with 6 bbl return. 13 3/8 pipe was cemented on back side with 14 bbl of cement. Current depth is 550 ft. PC planning to drill to 1000 ft and set surface string (7¿). Anticipated depth is 3760¿. |
1946087 | Primary Facility | 2011-01-27 | Drilling/Alteration | No Violations Noted | Well Id sign and E&S plan present at access road. At the time of inspcetion, no E&S or IW discharge issues at the site. Pit covered with 20 mil plastic and surrounded by security fence. No freeboard issues. Filter fence present on the down gradient side of site. 4¿ pipe was in the process of being set 3655 ft. Depth of well is TD at 3800 ft. Wire line completed on well prior to setting 4¿ pipe |
1946292 | Primary Facility | 2011-01-31 | Routine/Complete Inspection | No Violations Noted | At the time of inspection, well sign and ES plan onsite. Well drilled, not yet equipped for production. Access road and pad snow covered. No accelerated ES issues observed at this inspection, but recommend that in the future filter fence should be installed below brush/grub line in order to resist the potential for accelerated erosion. It is also recommended that operator continue to closely monitor and maintain all temporary bmp¿s until final restoration is complete. One below grade pit onsite properly lined with adequate freeboard. Operator plans to encapsulate drill cuttings at minimum of 20in above seasonal high ground water table. |
2049810 | Primary Facility | 2012-03-01 | Routine/Complete Inspection | No Violations Noted | At the time of inspection, no E&S issues were present at the site. Gas well was in production. |
2093214 | Primary Facility | 2012-07-16 | Routine/Complete Inspection | No Violations Noted | At the time of inspection, no E&S issues were present at the site. Gas well was in production. |
2232208 | Primary Facility | 2013-09-03 | Routine/Complete Inspection | No Violations Noted | At the time of inspection, no E&S issues were present at the site. Gas well was in production. |
2372826 | Primary Facility | 2015-05-15 | Routine/Complete Inspection | No Violations Noted | At the time of inspection, no E&S issues were present at the site. Gas well was in production. |
2466694 | Primary Facility | 2016-03-17 | Routine/Complete Inspection | No Violations Noted | no issues. gas well in production. |
2603807 | Primary Facility | 2017-06-01 | Routine/Complete Inspection | No Violations Noted | no issues. system running. |
2633418 | Primary Facility | 2017-09-07 | Routine/Complete Inspection | No Violations Noted | |
2698090 | Primary Facility | 2018-02-26 | Routine/Complete Inspection | No Violations Noted | Well tag present and emergency contact information present. No issues at the site |
For data sources see[7]