If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-023-20123 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.415682,"lon":-78.248698,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Cameron | |
Municipality: Lumber Township | |
Operator Name: SAMSON EXPLORATION LLC | |
Well Pad ID: 147025 | |
Farm/Lease Name: PARDEE & CURTIN LUMBER CO | |
License Status: Plugged and Abandoned | |
Spud Date: 2008-12-05 | |
Permit Date: 2008-11-05 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: No | |
Latitude: 41.415682 | |
Longitude: -78.248698 |
Date | Event |
---|---|
2008-11-05 | New Permit Application |
2008-12-08 | Performed Spud Operation |
2009-03-01 | Drilling Completion |
2009-05-04 | Performed Stimulation |
2009-05-08 | Performed Stimulation |
2009-05-09 | Performed Stimulation |
2009-05-10 | Performed Stimulation |
2009-05-11 | Perforation |
2009-05-11 | Performed Stimulation |
2009-07-30 | DEVIATED |
2016-04-14 | Inactive Well Request Granted |
2017-09-12 | Begin Plugging |
2017-10-19 | Finished Plugging |
For data sources see[4]
Stimulation Date | Phase Number | Chemical Agent | Volume (gal) | Treating Pressure (psi) | Breakdown Pressure (psi) |
---|---|---|---|---|---|
2009-05-04 | Sand | 0 | 0 | 0 |
For data sources see[5]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2009 | J W OPERATING CO | 32240.00 | 208 | 0.00 | 0 | 0.00 | 0 |
2010 | J W OPERATING CO | 52,736.00 | 358 | 0.00 | 0 | 0.00 | 0 |
2011 | J W OPERATING CO | 32,035.00 | 339 | 0.00 | 0 | 0.00 | 0 |
2012 | ENDEAVOUR OPERATING CORP | 12,879.80 | 342 | 0.00 | 0 | 0.00 | 0 |
2013 | ENDEAVOUR OPERATING CORP | 11,638.00 | 343 | 0.02 | 2 | 0.02 | 2 |
2014 | SAMSON EXPLORATION LLC | 8,500.00 | 205 | 0.00 | 0 | 0.00 | 0 |
2015 | SAMSON EXPLORATION LLC | 2,652.00 | 30 | 0.00 | 0 | 0.00 | 0 |
2016 | SAMSON EXPLORATION LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2017 | SAMSON EXPLORATION LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
For data sources see[6]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2009 | J W OPERATING CO | Brine | 4,278.00 Bbl | Brine or Industrial Waste Treatment Plt | PA0102784 |
2010 | J W OPERATING CO | Produced Fluid | 5,752.41 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0102784 |
2011 | J W OPERATING CO | Produced Fluid | 1,428.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2011 | J W OPERATING CO | Produced Fluid | 1,552.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0102784 |
2012 | ENDEAVOUR OPERATING CORP | Produced Fluid | 125.30 Bbl | INJECTION DISPOSAL WELL | 34-155-21447 |
2012 | J W OPERATING CO | Produced Fluid | 331.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2013 | ENDEAVOUR OPERATING CORP | Produced Fluid | 67.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0102784 |
2013 | ENDEAVOUR OPERATING CORP | Produced Fluid | 93.00 Bbl | CENT WASTE TRT FAC NPDES DISCHARGE | PA0102784 |
2013 | ENDEAVOUR OPERATING CORP | Produced Fluid | 93.00 Bbl | CENT WASTE TRT FAC NPDES | PA0102784 |
2014 | SAMSON EXPLORATION LLC | Produced Fluid | 335.00 Bbl | INJECTION DISPOSAL WELL | 34-133-24096 |
2014 | ENDEAVOUR OPERATING CORP | Produced Fluid | 82.00 Bbl | CENT WASTE TRT FAC NPDES DISCHARGE | PA0102784 |
2014 | ENDEAVOUR OPERATING CORP | Produced Fluid | 82.00 Bbl | CENT WASTE TRT FAC NPDES | PA0102784 |
2014 | SAMSON EXPLORATION LLC | Produced Fluid | 258.00 Bbl | STORAGE PENDING DISPOSAL OR REUSE | |
2015 | SAMSON EXPLORATION LLC | Produced Fluid | 180.00 Bbl | STORAGE PENDING DISPOSAL OR REUSE | |
2016 | SAMSON EXPLORATION LLC | Other Oil & Gas Wastes | 388.00 Bbl | REUSE OTHER THAN ROAD SPREADING |
For data sources see[7]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
1754483 | Primary Facility | 2008-12-05 | Drilling/Alteration | Violation(s) Noted | |
1761687 | Primary Facility | 2008-12-30 | Drilling/Alteration | No Violations Noted | |
1770144 | Primary Facility | 2009-02-17 | Drilling/Alteration | No Violations Noted | |
1772847 | Primary Facility | 2009-02-06 | Drilling/Alteration | No Violations Noted | |
1835457 | Primary Facility | 2009-10-15 | Routine/Complete Inspection | Viol(s) Noted & Immediately Corrected | operator in violation no well tag installed on a completed well,also e&s controls on a water storage pit has water erosion,also violation of 2ft free board violation |
1909242 | Primary Facility | 2010-05-26 | Routine/Complete Inspection | No Violations Noted | |
1995018 | Primary Facility | 2011-08-11 | Site Restoration | No Violations Noted | |
2073256 | Primary Facility | 2012-06-05 | Routine/Complete Inspection | No Violations Noted | |
2343108 | Primary Facility | 2015-02-10 | Routine/Complete Inspection | No Violations Noted | |
2406196 | Primary Facility | 2015-09-02 | Routine/Complete Inspection | No Violations Noted | |
2466012 | Primary Facility | 2016-03-16 | Routine/Complete Inspection | No Violations Noted | |
2566968 | Primary Facility | 2017-03-01 | Routine/Complete Inspection | No Violations Noted | |
2570057 | Primary Facility | 2017-03-09 | Routine/Complete Inspection | No Violations Noted | |
2635541 | Primary Facility | 2017-09-13 | Plugging(Includes Plugged/Mined Through) | No Violations Noted | Rig on location for P&A. Discussed procedure w/ Companyman. Bottomhole will be isolated by setting CIBP in tbg on production packer, pull off packer and cap w/ cmt. The operator expects to retrieve ~2200 of 5 1/2 and plug remainder of well in accordance w/ regulations. No issues observed |
2640078 | Primary Facility | 2017-09-25 | Plugging(Includes Plugged/Mined Through) | No Violations Noted | Rig off location following plugging ops. Production tree on well. Valves open to treetop 100% gas detected. B Section wing valve open, 100% gas. Audible leaking at spool flange. A Section shut in---production csg was recovered below show allowing access to outer csg at wing valve. Cellar dry. Operator expected to return to remediate and finish P&A. |
2647350 | Primary Facility | 2017-10-13 | Plugging(Includes Plugged/Mined Through) | No Violations Noted | Rig back on location, previous plugs failed. Rig drilled out lockcem plugs, cleaned out to casing stub and loaded hole with heavier mud, planning to set plugs again next week. No obvious major issues observed. |
2656953 | Primary Facility | 2017-11-03 | Plugging(Includes Plugged/Mined Through) | No Violations Noted | Rig off location following P&A. Production tree on well. Cellar and wellhead is flooded above wing valves on b section-- no bubbling. Well was venting at tree top. A trace of gas detected with Altair 5x gas meter. 0-20 LEL. No significant flow or pressure observed. |
2663014 | Primary Facility | 2017-11-21 | Routine/Complete Inspection | No Violations Noted | Routine inspection of Samson Exploration's Well Pad C on November 21, 2017. This well pad is not covered under an ESCGP; it falls under the 5 acre threshold. There is one Marcellus well (023-20123) located on this well pad. This well has recently been plugged and is represented by a tagged well monument.
Samson will be restoring this site under an E&S plan. This pad was built on relatively flat ground and will be restored back to approximate original contour. During my inspection I observed 2 roll off containers and a frac container which looks like it was used to hold cementing materials. In addition, I observed some ruts throughout the well pad. No sediment was observed leaving the site. E&S BMP controls will need to be installed prior to any earth disturbance work. |
2663482 | Primary Facility | 2017-11-21 | Plugging(Includes Plugged/Mined Through) | No Violations Noted | Routine inspection of a plugged well. Rig off location following re-plug. Well has 2" candy cane vent, open and venting. Approximately 10 % gas was detected at the vent opening. No gas was detected outside the vent and no bubbling was observed in standing water around well. As I went on to inspect other wells on the lease I called the operator to arrange meeting to further evaluate this well. I met the operator approximately one hour later at the 7H. A 1-160 PSI pressure gauge was fitted to the well and monitored for several minutes. The well did not move the needle of the pressure gauge and the volume when removing the gauge was minimal, bled off in approximately one second or less. |
2668728 | Primary Facility | 2017-12-06 | Routine/Complete Inspection | No Violations Noted | Routine inspection of Samson Exploration's Well Pad C on December 6, 2017. This well pad is not covered under an ESCGP; it falls under the 5 acre threshold. There is one Marcellus well (023-20123) located on this well pad. This well has recently been plugged and is represented by a tagged well monument.
Samson has restored this site under an E&S plan. This pad was built on relatively flat ground and has been restored back to approximate original contour. Some miscellaneous materials remain onsite from the plugging operation. I recommend removing these materials. Some rutting within the restored area was observed. No sediment was observed leaving the site. No violations noted. |
2670206 | Primary Facility | 2017-12-13 | Administrative/File Review | No Violations Noted | December 13, 2017: Certificate of Well Plugging for the Pardee and Curtin Lumber Co C-7H (023-20123) received, reviewed, signed, and sent to file. |
2687599 | Primary Facility | 2018-01-26 | Routine/Complete Inspection | No Violations Noted | Routine site inspection of Samson Explorations Well Pad C (Pardee & Curtin Lumber Co C7H) on January 19, 2018. This well pad is not covered under an ESCGP; it falls under the 5 acre threshold.
There is one Marcellus well (023-20123) that was plugged during late fall 2017. This plugged well is represented by a labeled well monument (photo 1). The site has been restored under an E&S plan. The pad was built on relatively flat ground and has been put back to approximate original contour (photo 2). The site has been seeded and mulched. Some large ruts were observed on the restored pad during my inspection. I recommend regrading the rut areas once weather permits and then reseeding and mulching. A frac container stationed in secondary manmade containment remains onsite (photo 3). I recommend removing this frac container and containment materials weather permitting. |
2695981 | Primary Facility | 2018-02-20 | Plugging(Includes Plugged/Mined Through) | No Violations Noted | Routine inspection of a recently plugged well. The well has a 2" candy cane monument with well tag. No obvious major issues were observed. |
2721276 | Primary Facility | 2018-04-23 | Plugging(Includes Plugged/Mined Through) | No Violations Noted | A routine inspection of this plugged, unconventional well was conducted April 23, 2018. At the time of inspection, all casing is below ground level. There is a 2" candy cane vent extending 6' above ground level. There was no audible or visual flow coming from the vent. There was standing water on the pad next to the location of the well. No bubbling was observed. There were no obvious major issues observed. |
2744367 | Primary Facility | 2018-06-22 | Routine/Complete Inspection | No Violations Noted | Routine site inspection of Samson Explorations Well Pad C (Pardee & Curtin Lumber Co C7H) on June 22, 2018. This well pad is not covered under an ESCGP; it falls under the 5 acre threshold. There is one Marcellus well (023-20123) that was plugged during late fall 2017. This plugged well is represented by a labeled well monument (photo 1).
The site has been restored under an E&S plan. The pad was built on relatively flat ground and has been put back to approximate original contour (photo 2). Several large ruts and bare spots were observed. The Department recommends dressing up any rutted areas and reseeding bare spots. In addition, the Department recommends submitting a post plugging restoration report in accordance with Chapter 78a65(f). No violations noted. |
2759438 | Primary Facility | 2018-08-01 | Site Restoration | No Violations Noted | A well site restoration inspection of Samson Explorations Well Pad C (Pardee & Curtin Lumber Co C7H) was conducted on August 1, 2018 with Steve Trujilo of Samson and Joe Kunst of ARM Group. A post plugging site restoration report has been submitted for plugged well 023-20123. This well was plugged during late Fall 2017. This plugged well is represented by a tagged monument.
The construction of the well pad was not under an ESCGP; it falls under the 5 acre threshold. The site has been restored under an E&S plan. The pad was built on relatively flat ground and has been put back to approximate original contour. Large ruts observed during my last inspection in June have been addressed. Those areas have been regraded, more soil added, seeded and mulched. Germination on these areas is occurring. Per this inspection I approve the post plugging restoration report for 023-20123. |
Inspection ID | Violation ID | Violation Date | Date Resolved | Violation Code | Violation Type | Violation Comments |
---|---|---|---|---|---|---|
1754483 | 552320 | 12/05/2008 | 2008-12-05 | 201G - Failure to post permit number, operator name, address, telephone number in a conspicuous manner at the site during drilling | Administrative | |
1835457 | 573413 | 10/15/2009 | 2009-10-15 | 102.4 - Failure to minimize accelerated erosion, implement E&S plan, maintain E&S controls. Failure to stabilize site until total site restoration under OGA Sec 206(c)(d) | Environmental Health & Safety | |
1835457 | 573414 | 10/15/2009 | 2009-10-15 | 201TAG - Failure to install, in a permanent manner, the permit number on a completed well | Administrative | |
1835457 | 573415 | 10/15/2009 | 2009-10-15 | 78.56FRBRD - Failure to maintain 2' freeboard in an impoundment | Administrative |
Violation ID | Penalty ID | Penalty Code | Penalty Status | Penalty Date | Enforcement Date | Penalty Amount | Amount Collected |
---|---|---|---|---|---|---|---|
552320 | 241058 | NOV - Notice of Violation | Comply/Closed | 2008-12-30 |
For data sources see[8]