{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.605219,"lon":-78.351125,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Cameron | |
Municipality: Shippen Township | |
Operator Name: SENECA RESOURCES CO LLC | |
Well Pad ID: 150752 | |
Farm/Lease Name: SRC WT 5041 29H 50722 | |
License Status: | |
Spud Date: 2014-03-21 | |
Permit Date: 2014-03-10 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: No | |
Latitude: 41.605219 | |
Longitude: -78.351125 |
Date | Event |
---|---|
2014-03-10 | New Permit Application |
2014-03-21 | Performed Spud Operation |
2014-05-23 | New Permit Application |
2014-06-08 | Drilling Completion |
2014-09-04 | Perforation |
2015-03-30 | DEVIATED |
For data sources see[4]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2014-09-04 | 2014-09-22 | 6,010 | 10,290,600 | 0 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | Proppant 80/100 Oklahoma | Trican | Proppant | Silica | 14808-60-7 | 100 | 0.816669 | 0 |
FEAC 20 | Trican | Iron Control | Acetic acid | 64-19-7 | 50 | 0.0004009 | 0 | |
Citric acid | 77-92-9 | 30 | 0.00024054 | 0 | ||||
7.5% HydroChloric Acid | Trican | Acid | Hydrochloric Acid HCl | 7647-01-0 | 7.5 | 0.0395145 | 0 | |
AL-7NR | Trican | Corrosion Inhibitor | Prop-2-yn-1-ol | 107-19-7 | 1 | 0.00001132 | 0 | |
Sl-7 | Trican | Scale Inhibitor | Ethylene glycol | 107-21-1 | 30 | 0.00818078 | 0 | |
Water | Seneca Resources | Carrier/Base Fluid | Water | 7732-18-5 | 100 | 87.954 | 0 | |
MBC 516 | Trican | Biocide | Ethanol | 64-17-5 | 2.8 | 0.00027465 | 0 | |
Didecyl dimethyl ammonium chloride | 7173-51-5 | 8.3 | 0.00081414 | 0 | ||||
N-alkyl dimethyl benzyl ammonium chloride | 68424-85-1 | 5.5 | 0.00053949 | 0 | ||||
Glutaraldehyde | 111-30-8 | 27 | 0.00264842 | 0 | ||||
Proppant 30/50 Ottawa | Trican | Proppant | Crystalline silica (quartz) | 14808-60-7 | 100 | 5.61653 | 0 | |
FR-15 | Trican | Friction Reducer | Distillates (petroleum), Hydrotreated Light | 64742-47-8 | 25 | 0.0148287 | 0 | |
Proprietary Amide | Proprietary | 2.5 | 0.00148287 | 0 | ||||
Proppant 40/70 Ottawa | Trican | Proppant | Crystalline silica (quartz) | 14808-60-7 | 100 | 5.54388 | 0 |
For data sources see[5]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2014 | SENECA RESOURCES CO LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2015 | SENECA RESOURCES CO LLC | 492,205.82 | 112 | 0.00 | 0 | 0.00 | 0 |
2016 | SENECA RESOURCES CO LLC | 356,483.99 | 172 | 0.00 | 0 | 0.00 | 0 |
2017 | SENECA RESOURCES CO LLC | 300,975.01 | 191 | 0.00 | 0 | 0.00 | 0 |
2018 | SENECA RESOURCES CO LLC | 273,467.17 | 222 | 0.00 | 0 | 0.00 | 0 |
2019 | SENECA RESOURCES CO LLC | 343,359.33 | 365 | 0.00 | 0 | 0.00 | 0 |
For data sources see[6]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2014 | SENECA RESOURCES CO LLC | Drill Cuttings | 457.10 Tons | LANDFILL | 101397 |
2014 | SENECA RESOURCES CO LLC | Drill Cuttings | 640.21 Tons | LANDFILL | 100361 |
2015 | SENECA RESOURCES CO LLC | Produced Fluid | 5,191.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NW011 |
2015 | SENECA RESOURCES CO LLC | Fracing Fluid Waste | 80.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
2015 | SENECA RESOURCES CO LLC | Servicing Fluid | 85.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
2015 | SENECA RESOURCES CO LLC | Produced Fluid | 49,181.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016 | SENECA RESOURCES CO LLC | Synthetic Liner Materials | 0.40 Tons | LANDFILL | 100361 |
2016 | SENECA RESOURCES CO LLC | Produced Fluid | 4,190.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2016 | SENECA RESOURCES CO LLC | Other Oil & Gas Wastes | 160.80 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NW011 |
2016 | SENECA RESOURCES CO LLC | Produced Fluid | 39,943.67 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NW011 |
2016 | SENECA RESOURCES CO LLC | Produced Fluid | 11,723.50 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016 | SENECA RESOURCES CO LLC | Produced Fluid | 40.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NW005 |
2016 | SENECA RESOURCES CO LLC | Fracturing Fluid Waste | 10.56 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
2017 | SENECA RESOURCES CO LLC | Other Oil & Gas Wastes | 58.00 Bbl | REUSE (AT WELL PAD) | |
2017 | SENECA RESOURCES CO LLC | Other Oil & Gas Wastes | 206.66 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2017 | SENECA RESOURCES CO LLC | Produced Fluid | 27,664.08 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2017 | SENECA RESOURCES CO LLC | Produced Fluid | 3,522.00 Bbl | REUSE (AT WELL PAD) | |
2018 | SENECA RESOURCES CO LLC | Produced Fluid | 16,707.50 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2018 | SENECA RESOURCES CO LLC | Produced Fluid | 871.67 Bbl | INJECTION DISPOSAL WELL | PAS2D025BELK |
2018 | SENECA RESOURCES CO LLC | Produced Fluid | 737.50 Bbl | REUSE (AT WELL PAD) | |
2018 | SENECA RESOURCES CO LLC | Other Oil & Gas Wastes | 67.50 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2018 | SENECA RESOURCES CO LLC | Produced Fluid | 65.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW005 |
2019 | SENECA RESOURCES CO LLC | Produced Fluid | 40.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW005 |
2019 | SENECA RESOURCES CO LLC | Produced Fluid | 16.67 Bbl | INJECTION DISPOSAL WELL | 34-007-24355 |
2019 | SENECA RESOURCES CO LLC | Produced Fluid | 35.00 Bbl | RESIDUAL WASTE TRANSFER FACILITY | WMGR123NC039 |
2019 | SENECA RESOURCES CO LLC | Produced Fluid | 9,758.66 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2019 | SENECA RESOURCES CO LLC | Produced Fluid | 16.67 Bbl | INJECTION DISPOSAL WELL | 34-133-20525 |
2019 | SENECA RESOURCES CO LLC | Other Oil & Gas Wastes | 91.66 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2019 | SENECA RESOURCES CO LLC | Produced Fluid | 309.99 Bbl | REUSE (AT WELL PAD) | |
2019 | SENECA RESOURCES CO LLC | Produced Fluid | 16.67 Bbl | INJECTION DISPOSAL WELL | 34-155-21893 |
2019 | SENECA RESOURCES CO LLC | Produced Fluid | 1,760.00 Bbl | INJECTION DISPOSAL WELL | PAS2D025BELK |
For data sources see[7]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2256877 | Primary Facility | 2014-03-25 | Routine/Complete Inspection | No Violations Noted | |
2259714 | Primary Facility | 2014-04-02 | Routine/Complete Inspection | No Violations Noted | |
2270643 | Primary Facility | 2014-05-14 | Routine/Complete Inspection | No Violations Noted | |
2284125 | Primary Facility | 2014-07-02 | Routine/Complete Inspection | No Violations Noted | |
2286508 | Primary Facility | 2014-06-30 | Routine/Complete Inspection | No Violations Noted | |
2296809 | Primary Facility | 2014-08-20 | Routine/Complete Inspection | No Violations Noted | |
2308805 | Primary Facility | 2015-01-14 | Routine/Complete Inspection | No Violations Noted | At the time of inspection 1230pm, clear sky, 25 degrees F, light snow cover |
2344138 | Primary Facility | 2015-02-12 | Routine/Complete Inspection | No Violations Noted | At the time of inspection sunny sky, 30 degrees F, 20” snow cover. |
2358100 | Primary Facility | 2015-04-02 | Routine/Complete Inspection | No Violations Noted | |
2379737 | Primary Facility | 2015-06-17 | Routine/Complete Inspection | No Violations Noted | |
2491510 | Primary Facility | 2016-06-01 | Routine/Complete Inspection | No Violations Noted | |
2552061 | Primary Facility | 2017-01-12 | Routine/Complete Inspection | No Violations Noted | |
2575240 | Primary Facility | 2017-03-27 | Routine/Complete Inspection | No Violations Noted | C09D well pad occupied by (6) Marcellus wells. All wells tagged with API/Permit number at the flowline off each wellhead. All cellars full with rainwater to nearly pad elevation, frozen today. (6) skid-mounted production units serving the wells are spotted in a modular secondary containment. Production fluids separator dump lines are plumbed to (3) 400 bbl. vertical, steel production fluids tanks spotted in a modular secondary containment. Containments serving the production units and fluids tanks show 1"-2" rainwater, frozen at this inspection. Keystone Clearwater personnel on location activating the temporary diesel transfer pumps used to pump production fluids generated at the C08G pad and this pad, into the temporary, aboveground HDPE pipeline to the Clermont water management facility, for re-use during well stimulation on other Seneca locations.
Centralized freshwater impoundment in the shared C08F LOD shows 8'+ freeboard and is frozen. Since last previous inspection, a new ditchline has been |
2693480 | Primary Facility | 2018-02-10 | Routine/Complete Inspection | No Violations Noted | Routine site inspection of Seneca Resources Rich Valley Pad F and Freshwater Impoundment (FWI) on February 9, 2018. No one was onsite during my inspection.
The site sign, PPC plan, emergency response plan, and weekly inspection logs were onsite for review. The site and surrounding areas were covered in snow. No E & S issues were observed during the time of my inspection. There are (6) producing Marcellus wells located on this pad (023-20160, 023-20161, 023-20162, 023-20163, 023-20164, and 023-20165). All well-heads are tagged with API/Permit number. All well cellars were frozen. There are (6) GPU's stationed on the pad and (3) 400 bbl. vertical, steel production fluids tanks spotted in a modular secondary containment. Water within this containment was frozen. I observed some rusting streaks on the exterior of the produced fluids tanks. The Department recommends the operator continue to monitor the tanks and replace them if needed. A Freshwater Impoundment (FWI) falls under this ESCGP. The FWI is enclo |
2749061 | Primary Facility | 2018-07-03 | Routine/Complete Inspection | No Violations Noted | At the tim of this inspection this well was in production |
2849149 | Primary Facility | 2019-03-06 | Routine/Complete Inspection | No Violations Noted | At the time of this inspection this well as in production. A digital gauge on the well head assembly was showing a pressure of 398 psi ( pounds per square inch ) . There are three (3) annulus vents on this well that are vented to surface. These vents were tested for combustible gas with a Altair 5 x Multi Gas Meter. Results of this testing was 0% LEL ( lower explosion limit) and 0% Methane on the 20" x 13 3/8" vent. 0% LEL and 0% Methane on the 13 3/8" x 9 5/8" vent and 7% LEL and 0% Methane on the 9 5/8" x 5 1/2" vent. No violations were noted at this inspection. |
2850607 | Primary Facility | 2019-03-06 | Routine/Complete Inspection | No Violations Noted | Department representative Sue Herzing conducted a routine site inspection of Seneca Resources Rich Valley Pad F and Freshwater Impoundment (FWI) on March 6, 2019.
The well pad and surrounding areas were snow covered. No E&S issues were observed during the time of my inspection. No staining or spills were observed on the well pad. There are (6) producing Marcellus wells located on this pad (023-20160, 023-20161, 023-20162, 023-20163, 023-20164, and 023-20165). All well-heads are tagged with API/Permit number. All well cellars were frozen. There are (6) GPU's stationed on the pad and (3) 400 bbl. vertical, steel production fluids tanks spotted in a modular secondary containment. Water within this containment was frozen. I observed some rusting streaks on the exterior of the produced fluids tanks. The Department recommends the operator continue to monitor the tanks and replace them if needed. An approved extension of the well pad on the SW end remains in place ~ 350' L x 140' W. Currently road equipment |