Well ID: 37-023-20180
Loading map...
Country: United States
State: Pennsylvania
County: Cameron
Municipality: Shippen Township
Operator Name: SENECA RESOURCES CO LLC
Well Pad ID: 151772
Farm/Lease Name: SRC WT 5034
License Status: Active
Spud Date: 2015-03-14
Permit Date: 2014-10-10
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.570945
Longitude: -78.351350

For data sources see[1][2][3]

Well History

Date Event
2014-10-10 New Permit Application
2014-12-19 New Permit Application
2015-03-12 Performed Spud Operation
2015-05-25 Drilling Completion
2017-08-30 Perforation
2017-08-30 Performed Stage 1 of Stimulation
2017-08-31 Perforation
2017-09-01 Perforation
2017-09-01 Performed Stage 2 of Stimulation
2017-09-05 Perforation
2017-09-05 Performed Stage 3 of Stimulation
2017-09-05 Performed Stage 4 of Stimulation
2017-09-05 Performed Stage 5 of Stimulation
2017-09-07 Perforation
2017-09-08 Perforation
2017-09-08 Performed Stage 6 of Stimulation
2017-09-08 Performed Stage 7 of Stimulation
2017-09-08 Performed Stage 8 of Stimulation
2017-09-08 Performed Stage 9 of Stimulation
2017-09-09 Perforation
2017-09-10 Performed Stage 10 of Stimulation
2017-09-11 Perforation
2017-09-11 Performed Stage 11 of Stimulation
2017-09-11 Performed Stage 12 of Stimulation
2017-09-11 Performed Stage 13 of Stimulation
2017-09-13 Perforation
2017-09-14 Perforation
2017-09-14 Performed Stage 14 of Stimulation
2017-09-14 Performed Stage 15 of Stimulation
2017-09-15 Perforation
2017-09-15 Performed Stage 16 of Stimulation
2017-09-15 Performed Stage 17 of Stimulation
2017-09-18 Perforation
2017-09-18 Performed Stage 18 of Stimulation
2017-09-18 Performed Stage 19 of Stimulation
2017-09-19 Perforation
2017-09-19 Performed Stage 20 of Stimulation
2017-09-19 Performed Stage 21 of Stimulation
2017-09-20 Perforation
2017-09-20 Performed Stage 22 of Stimulation
2017-09-20 Performed Stage 23 of Stimulation
2017-09-21 Perforation
2017-09-21 Performed Stage 24 of Stimulation
2017-09-21 Performed Stage 25 of Stimulation
2017-09-24 Perforation
2017-09-24 Performed Stage 26 of Stimulation
2017-09-24 Performed Stage 27 of Stimulation
2017-09-24 Performed Stage 28 of Stimulation
2017-09-25 Perforation
2017-09-25 Performed Stage 29 of Stimulation
2017-09-26 Perforation
2017-09-26 Performed Stage 30 of Stimulation
2017-09-26 Performed Stage 31 of Stimulation
2017-09-27 Perforation
2017-09-27 Performed Stage 32 of Stimulation
2017-09-27 Performed Stage 33 of Stimulation
2017-09-27 Performed Stage 34 of Stimulation
2017-09-28 Perforation
2017-09-28 Performed Stage 35 of Stimulation
2020-02-25 Deviated

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2017-08-30 2017-09-29 5,377 8,400,420 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 KFEAC-30 Keane Iron Control Acetic acid 64-19-7 60.00000 0.00047
Citric acid 77-92-9 40.00000 0.00031
DustProof (Proppant) Keane Proppant Crystalline silica: Quartz (SiO2) 14808-60-7 99.90000 11.39831
Blend Proprietary 0.10000 0.01141
Water (Clean - Acid - Chems) Seneca Resources Carrier/Base Fluid Water 7732-18-5 100.00000 87.81408
KAI-12 Keane Acid Inhibitor ethylbenzene 100-41-4 1.00000 0.00001
fatty imidazoline 61790-69-0 5.00000 0.00006
propan-2-ol 67-63-0 5.00000 0.00006
methanol 67-56-1 90.00000 0.00111
alcohols, c7-9-0so, c8-rich 68526-83-0 5.00000 0.00006
prop-2-yn-1-0l 107-19-7 5.00000 0.00006
xylne 1330-20-7 5.00000 0.00006
KFR-20 Keane Friction Reducer cololymer of 2-propenamide 69418-26-4 30.00000 0.02827
Water 7732-18-5 45.00000 0.04241
oleic acid diethanolamide 93-83-4 2.00000 0.00188
Mineral oil/ light hydrotreated pet. distillate 64742-47-8 20.00000 0.01885
Alcohols, C12-16, ethoxylated 68551-12-2 2.00000 0.00188
Ammonium Chloride 12125-02-9 1.00000 0.00094
KSI-19 NW Keane Scale Inhibitor Aqueous Solution Proprietary 100.00000 0.01022
7.5% Acid Keane Acidizing Hydrochloric Acid 7647-01-0 7.50000 0.03549
Water 7732-18-5 92.50000 0.43768
Sand (Proppant) (lbs) Keane Proppant Crystalline silica: Quartz (SiO2) 14808-60-7 100.00000 0.18785
MBC-516 Keane Biocide quaternary ammonium compounds,
benzyl-C12-16- alkyldimethyl, chlorides
68424-85-1 5.30000 0.00046
ethanol 64-17-5 2.80000 0.00024
gluteral 111-30-8 26.70000 0.00232
Didecyl dimethyl ammonium chloride 7173-51-5 8.00000 0.00069

For data sources see[5]

Stimulation Data

Stimulation Date Phase Number Chemical Agent Volume (gal) Treating Pressure (psi) Breakdown Pressure (psi)
2017-08-30 1 Ottawa 7,286,496 7,049 7,927
2017-09-01 2 Ottawa 7,286,496 7,780 5,498
2017-09-05 3 Ottawa 7,286,496 7,551 5,098
2017-09-05 4 Ottawa 7,286,496 7,664 5,032
2017-09-05 5 Ottawa 7,286,496 7,607 4,481
2017-09-08 6 Ottawa 7,286,496 7,650 4,882
2017-09-08 7 Ottawa 7,286,496 7,699 5,662
2017-09-08 8 Ottawa 7,286,496 7,634 5,129
2017-09-08 9 Ottawa 7,286,496 7,572 5,445
2017-09-10 10 Ottawa 7,286,496 7,318 5,948
2017-09-11 11 Ottawa 7,286,496 7,467 5,658
2017-09-11 12 Ottawa 7,286,496 7,456 5,458
2017-09-11 13 Ottawa 7,286,496 7,285 4,998
2017-09-14 14 Ottawa 7,286,496 7,269 5,449
2017-09-14 15 Ottawa 7,286,496 7,173 5,421
2017-09-15 16 Ottawa 7,286,496 7,291 4,797
2017-09-15 17 Ottawa 7,286,496 7,180 5,396
2017-09-18 18 Ottawa 7,286,496 7,409 5,771
2017-09-18 19 Ottawa 7,286,496 7,238 5,662
2017-09-19 20 Ottawa 7,286,496 6,591 5,499
2017-09-19 21 Ottawa 7,286,496 6,919 5,574
2017-09-20 22 Ottawa 7,286,496 7,305 5,342
2017-09-20 23 Ottawa 7,286,496 7,192 4,582
2017-09-21 24 Ottawa 7,286,496 7,212 4,372
2017-09-21 25 Ottawa 7,286,496 7,188 4,662
2017-09-24 26 Ottawa 7,286,496 7,263 5,510
2017-09-24 27 Ottawa 7,286,496 7,306 5,161
2017-09-24 28 Ottawa 7,286,496 7,023 4,319
2017-09-25 29 Ottawa 7,286,496 6,657 4,785
2017-09-26 30 Ottawa 7,286,496 6,789 5,071
2017-09-26 31 Ottawa 7,286,496 6,257 4,637
2017-09-27 32 Ottawa 7,286,496 6,240 5,212
2017-09-27 33 Ottawa 7,286,496 6,272 4,669
2017-09-27 34 Ottawa 7,286,496 6,156 4,342
2017-09-28 35 Ottawa 7,286,496 6,312 4,032

For data sources see[6]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2015 SENECA RESOURCES CO LLC 0.00 0 0.00 0 0.00 0
2016 SENECA RESOURCES CO LLC 0.00 0 0.00 0 0.00 0
2017 SENECA RESOURCES CO LLC 99,987.46 60 0.00 0 0.00 0
2018 SENECA RESOURCES CO LLC 297,930.23 363 0.00 0 0.00 0
2019 SENECA RESOURCES CO LLC 151,845.47 318 0.00 0 0.00 0

For data sources see[7]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2015 SENECA RESOURCES CO LLC Drill Cuttings 1,334.19 Tons LANDFILL 100361
2016 SENECA RESOURCES CO LLC Synthetic Liner Materials 3.21 Tons LANDFILL 100361
2016 SENECA RESOURCES CO LLC Other Oil & Gas Wastes 96.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016 SENECA RESOURCES CO LLC Other Oil & Gas Wastes 25.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NW005
2016 SENECA RESOURCES CO LLC Servicing Fluid 96.25 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NW011
2016 SENECA RESOURCES CO LLC Other Oil & Gas Wastes 165.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NW011
2017 SENECA RESOURCES CO LLC Produced Fluid 50,574.32 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2017 SENECA RESOURCES CO LLC Other Oil & Gas Wastes 55.00 Bbl REUSE (AT WELL PAD)
2017 SENECA RESOURCES CO LLC Synthetic Liner Materials 0.73 Tons LANDFILL 100361
2017 SENECA RESOURCES CO LLC Other Oil & Gas Wastes 318.53 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2017 SENECA RESOURCES CO LLC Unused Fracturing Fluid Waste 279.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123
2017 SENECA RESOURCES CO LLC Produced Fluid 79.00 Bbl REUSE (AT WELL PAD)
2017 SENECA RESOURCES CO LLC Produced Fluid 162.50 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW005
2017 SENECA RESOURCES CO LLC Waste Water Treatment Sludge 27.32 Tons RESIDUAL WASTE PROCESSING FACILITY WMGR123NW005
2018 SENECA RESOURCES CO LLC Produced Fluid 47,565.37 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2018 SENECA RESOURCES CO LLC Soil Contaminated by Oil & Gas Related Spills 8.24 Tons LANDFILL 100361
2018 SENECA RESOURCES CO LLC Produced Fluid 208.75 Bbl INJECTION DISPOSAL WELL PAS2D025BELK
2018 SENECA RESOURCES CO LLC Soil Contaminated by Oil 8.24 Tons LANDFILL 100361
2018 SENECA RESOURCES CO LLC Produced Fluid 131.25 Bbl REUSE (AT WELL PAD)
2018 SENECA RESOURCES CO LLC Other Oil & Gas Wastes 1.25 Bbl INJECTION DISPOSAL WELL PAS2D025BELK
2018 SENECA RESOURCES CO LLC Other Oil & Gas Wastes 331.29 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2018 SENECA RESOURCES CO LLC Synthetic Liner Materials 0.50 Tons LANDFILL 100361
2018 SENECA RESOURCES CO LLC Produced Fluid 12.50 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW005
2019 SENECA RESOURCES CO LLC Synthetic Liner Materials 0.26 Tons LANDFILL 100361
2019 SENECA RESOURCES CO LLC Produced Fluid 12,269.40 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2019 SENECA RESOURCES CO LLC Other Oil & Gas Wastes 641.09 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2019 SENECA RESOURCES CO LLC Produced Fluid 491.08 Bbl INJECTION DISPOSAL WELL PAS2D025BELK
2019 SENECA RESOURCES CO LLC Produced Fluid 183.50 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW005
2019 SENECA RESOURCES CO LLC Other Oil & Gas Wastes 111.32 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW005
2019 SENECA RESOURCES CO LLC Produced Fluid 225.25 Bbl REUSE (AT WELL PAD)

For data sources see[8]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2351139 Primary Facility 2015-03-11 Routine/Complete Inspection No Violations Noted
2353600 Primary Facility 2015-03-19 Routine/Complete Inspection No Violations Noted
2355706 Primary Facility 2015-03-25 Drilling/Alteration No Violations Noted At the time of inspection Cloudy sky, light rain and ~33° F.
2357082 Primary Facility 2015-04-01 Routine/Complete Inspection No Violations Noted
2358084 Primary Facility 2015-04-02 Routine/Complete Inspection No Violations Noted
2359976 Primary Facility 2015-04-07 Routine/Complete Inspection No Violations Noted At the time of inspection cloudy sky, light rain and ~45° F.
2365282 Primary Facility 2015-04-23 Routine/Complete Inspection No Violations Noted
2372839 Primary Facility 2015-05-26 Routine/Complete Inspection No Violations Noted
2378102 Primary Facility 2015-06-05 Drilling/Alteration No Violations Noted At the time of inspection sunny sky, ~ 70° F.
2432282 Primary Facility 2015-12-08 Routine/Complete Inspection No Violations Noted
2470511 Primary Facility 2016-03-30 Routine/Complete Inspection No Violations Noted
2474099 Primary Facility 2016-04-12 Routine/Complete Inspection No Violations Noted
2506063 Primary Facility 2016-07-27 Routine/Complete Inspection No Violations Noted
2610259 Primary Facility 2017-06-13 Routine/Complete Inspection No Violations Noted
2616247 Primary Facility 2017-07-18 Administrative/File Review Violation(s) Noted Administrative Inspection Record created for the purpose of entering Enforcement Record for failure to plug an abandoned well.
2622122 Primary Facility 2017-07-26 Routine/Complete Inspection No Violations Noted Routine inspection of Seneca Resources Corp CRV PAD C09-G on July 26, 2017. No one was onsite during my inspection.

Rig mats remain onsite with a total of 25 produced fluids frac containers. It appears that the operator is gearing up for well stimulation. All wells are labeled with the well number and operator. A total of 9 wells have been TD. Well 023-20182 has been drilled and plugged.

There are 6 produced fluids silos located in secondary containment onsite. Field screen reading for specific conductance within this containment was 82.0 uS/cm.

Overall, the pad is in good condition and all necessary BMPs are in place surrounding the well pad.

The sign located at the entrance to the well pad only has a total of 7 well listed. This does not match with the number of drilled wells onsite. I recommend updating the well site to reflect the number of drilled wells onsite.

2627518 Primary Facility 2017-08-18 Routine/Complete Inspection No Violations Noted Routine inspection of Seneca Resources Corp CRV PAD C09-G on August 17, 2017 with company man Adam Pierce of Seneca Resources.

Crews were currently working on fracing Marcellus wells 023-20178, 023-20179, 023-20183, and 023-20184. The fracing crew was approximately half way done with fracing these four wells. Once finished they will move the rig over and work on stimulating Marcellus wells 023-20180, 023-20181, 023-20182, and 023-20198. According to Mr. Pierce, crews are installing a perforation string downhole and with 8 perforation holes per every 2 ft. section of the string. Plugs made of a composite are being placed between 190 ft. perforation stages.

Sand is being hauled via trucks from the Cameron County rail yard. Water used for stimulation is being transferred to this pad via the above ground water line from the Clermont Water Treatment Facility. The above ground waterline is plumbed into a series of manifolded frac tanks.

All equipment is placed on secondary containment. Overall, the pad is i

2630942 Primary Facility 2017-08-15 Routine/Complete Inspection No Violations Noted
2643026 Primary Facility 2017-09-28 Routine/Complete Inspection No Violations Noted Routine inspection of Seneca Resources Corp CRV PAD C09-G on September 28, 2017 with company man Scott Digel of Seneca Resources.

Crews were currently working on fracing Marcellus wells 023-20182, 023-20183, and 023-20184. The fracing crew was almost completed with well stimulation on these 3 wells. Stimulation been completed on wells 023-20178, 023-20179, 023-29180, 023-20181, and 023-20198. According to Mr. Digel, once all of the wells have been stimulated, crews will remove this rig and bring in 2 work-over rigs to drill out the plugs on the above mentioned wells.

Sand is being hauled via trucks from the Cameron County rail yard, then being trucked to this site. Water used for well stimulation is being transferred to this pad via the above ground water line from the Clermont Water Treatment Facility. The above ground waterline is plumbed into a series of manifolded frac tanks. These tanks are located along the Eastern border of the pad.

All equipment is placed on secondary containment. Overall, th

2668233 Primary Facility 2017-12-06 Routine/Complete Inspection No Violations Noted This well was in production at the time of this inspection. The tubing pressure (production) was 1018 psi. at this inspection. All fittings and vented annulus were checked at this inspection. The pad and well area are neat and organized.
2672472 Primary Facility 2017-12-15 Routine/Complete Inspection No Violations Noted Routine inspection of Seneca Resources CRV PAD C09-G on December 15, 2017.

There are a total of 8 producing Marcellus wells located on this pad. Rig mats from the recent flowback operation have been removed and are currently being stationed along the N edge of the well pad. There is one frac tank stationed on man-made secondary containment with a berm near the well heads. There are 4 frac tanks located near the produced fluids containment along the S border. These frac tanks are currently not located in secondary containment nor to they appear to be connected to anything. There are (6) 400 BBL produced fluids tanks located in modular secondary containment. Water within the containment is frozen and snow covered. In addition, there's a row of 22 frac tanks stationed along the E edge of the well pad. This series of 22 frac tanks are stationed in secondary man made containment with a berm. There are 8 gas production units stationed along the W edge of the well pad.

The pad and surrounding areas are snow cove

2707913 Primary Facility 2018-03-20 Routine/Complete Inspection No Violations Noted At the time of this inspection this well was in production. The wellhead assembly, annulus vents 20" x 13 3/8", 13 3/8" x 9 5/8" and 9 5/8" x 5 1/2" were tested for gas. Results of this testing was that 100% LEL(lower explosion limit) and 7% Methane was detected on the 9 5/8" x 5 1/2" annulus vent. No other gas was detected on the wellhead assembly or the well area.
2734710 Primary Facility 2018-05-24 Incident- Response to Accident or Event No Violations Noted I arrived onsite and met with Jeff Passarello of Seneca in response to a spill report. Between 3 and 4 AM on 5/24, a worker on the site set up to pump produced water from both the Baker tank battery and the production tanks to the Clermont storage facility. The same pump is used to pump water from the well cellars (when needed) along with the produced water, but no pumping was occurring at the cellars. A water line is left in place to the cellars, but capped ~20' from the cellars to allow vehicle traffic through. When the worker turned on the pump, the cap popped off of the water line to the cellars and spilled ~1 1/2 barrels of produced water from the pump to the pad surface. When I arrived, approximately a third to a half of the spill area had already been excavated and a 30 yard dumpster filled. Jeff informed me that they were waiting on another rolloff to continue the excavation. The gravel was underlain by a clay layer, making visual confirmation of the spill removal possible, but Jeff was also u
2792968 Primary Facility 2018-10-16 Routine/Complete Inspection No Violations Noted Department representative Sue Herzing conducted a routine site inspection at Seneca Resources CRV C09-G Well Pad on October 16, 2018. There are a total of 8 drilled and producing wells located on this well pad. All well heads are properly tagged. Well cellars are full of water. No bubbling or sheen observed in the cellars. There are (6) 400 bbl. produced fluids tanks stationed in secondary containment. Approximately 1" of rain water was found in the produced fluids secondary containment with a conductivity reading of 78.8 uS/cm. A series of 12 manifolded frac tanks are being stationed on secondary along the NE edge of the well pad. Just a trace of water was observed within this containment. Overall, the well site looks good. No violations noted.
2807498 Primary Facility 2018-11-28 Routine/Complete Inspection No Violations Noted At the time of this inspection this well was in production. There are two (3) annulus vents openly venting on this well. No other annulus vents were noted venting at this inspection. No violations noted at the time of this inspection.
2808924 Primary Facility 2018-11-29 Routine/Complete Inspection No Violations Noted Seneca Resources submitted a spud notice to the Department via the Greenport system on November 21, 2018 for the following Utica wells: 023-20238 through 023-20243.

Department representative Sue Herzing conducted a routine site inspection at Seneca Resources CRV Pad C09-G on November 29, 2018. Each 20" round 100' in length conductor was in-place for the above listed wells. In addition, there are a total of 8 producing Marcellus wells located on the pad.

Overall, the well pad was snow covered and frozen. No signs of leaks or spills were observed on the well pad.

No violations noted.

2843485 Primary Facility 2019-02-21 Routine/Complete Inspection No Violations Noted At the time of this inspection this well was not in production (temporarily shut in). 614 psi (pounds per square inch) was showing on the production/ flow line at the time of this inspection. This well has 3 annulus vents vented to surface. The annulus vents were all tested for combustible gas with a Altair 5 x Multi gas meter. The results were the 20" x 13" tested 0% LEL (lower explosion limit) and 0% METHANE. 13" x 9" tested 0% LEL (lower explosion limit) and 0% METHANE. The 9" x 5" tested 0% LEL (lower explosion limit) and 0% METHANE. This meter was calibrated on 2-20-19. No violations noted at this inspection.

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
2616247 791560 2017-07-18 2017-08-16 78a91(a) Environmental Health & Safety The SRC WT 5034 82H well was drilled to total depth on May 27, 2015 under the authorization of well permit number 023-20180. No production has ever been reported for the SRC WT 5034 82H well. The well is therefore considered "abandoned" in accordance with Section 3203 of the 2012 Oil and Gas Act,

Penalties Applied

Violation ID Penalty ID Penalty Code Penalty Status Penalty Date Enforcement Date Penalty Amount Amount Collected
791560 356250 NOV - Notice of Violation 2017-08-16

For data sources see[9]