If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-023-20201 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.587106,"lon":-78.374842,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Cameron | |
Municipality: Shippen Township | |
Operator Name: SENECA RESOURCES CO LLC | |
Well Pad ID: 152437 | |
Farm/Lease Name: SRC WT 2353 130H 51479 | |
License Status: | |
Spud Date: | |
Permit Date: 2015-05-07 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: No | |
Latitude: 41.587106 | |
Longitude: -78.374842 |
Date | Event |
---|---|
2015-05-07 | New Permit Application |
2015-06-19 | Performed Spud Operation |
For data sources see[4]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2017-03-17 | 2017-03-29 | 6,105 | 5,502,250 | 0 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | Water (Clean - Acid - Chems) | Seneca Resources | Carrier/Base Fluid | Water | 7732-18-5 | 100 | 81.6299 | 45,916,300.0 |
MBC-516 | Keane | Biocide | Didecyl dimethyl ammonium chloride | 7173-51-5 | 8 | 0.000671667 | 377.808 | |
N-alkyl dimethyl benzyl ammonium chloride | 68424-85-1 | 5.3 | 0.000447497 | 251.714 | ||||
Ethanol | 64-17-5 | 2.8 | 0.000235968 | 132.731 | ||||
gluteral | 111-30-8 | 26.7 | 0.00225013 | 1265.68 | ||||
KSI-16 | Keane | Scale Inhibitor | Water | 7732-18-5 | 60 | 0.00941487 | 5295.8 | |
ethylene glycol | 107-21-1 | 40 | 0.00627658 | 3530.54 | ||||
Ammonia | 7664-41-7 | 1 | 0.000156915 | 88.263 | ||||
Alkyl Phosphonic Acid | Proprietary | 10 | 0.00156915 | 882.634 | ||||
7.5% Acid | Keane | Acidizing | Water | 7732-18-5 | 92.5 | 0.481774 | 270995 | |
Hydrochloric Acid | 7647-01-0 | 7.5 | 0.0390628 | 21972.5 | ||||
KFR-20 | Keane | Friction Reducer | Mineral oil/ light hydrotreated pet. distillate | 64742-47-8 | 20 | 0.0172884 | 9724.59 | |
Alcohols, C12-16, ethoxylated | 68551-12-2 | 2 | 0.00172884 | 972.46 | ||||
9-Octadecenamide,N,N-bis(2-hydroxyethyl)-, (9Z)- | 93-83-4 | 2 | 0.00172884 | 972.46 | ||||
cololymer of 2-propenamide | 69418-26-4 | 30 | 0.0259326 | 14586.9 | ||||
Water | 7732-18-5 | 45 | 0.0388988 | 21880.3 | ||||
Ammonium Chloride | 12125-02-9 | 1 | 0.000864419 | 486.23 | ||||
KAI-12 | Keane | Acid Inhibitor | ethylbenzene | 100-41-4 | 1 | 0.00001355 | 7.624 | |
fatty imidazoline | 61790-69-0 | 5 | 0.00006777 | 38.121 | ||||
alcohols, c7-9-0so, c8-rich | 68526-83-0 | 5 | 0.00006777 | 38.121 | ||||
Xylene | 1330-20-7 | 5 | 0.00006777 | 38.121 | ||||
propan-2-ol | 67-63-0 | 5 | 0.00006777 | 38.121 | ||||
prop-2-yn-1-0l | 107-19-7 | 5 | 0.00006777 | 38.121 | ||||
methanol | 67-56-1 | 90 | 0.00121989 | 686.179 | ||||
Other Chemical(s) | Listed Above | See Trade Name(s) List | 9-Octadecenamide,N,N-bis(2-hydroxyethyl)-, (9Z)- | 93-83-4 | 2 | 0.00172884 | 972.46 | |
alcohols, c7-9-0so, c8-rich | 68526-83-0 | 5 | 0.00006777 | 38.121 | ||||
ethylbenzene | 100-41-4 | 1 | 0.00001355 | 7.624 | ||||
Alcohols, C12-16, ethoxylated | 68551-12-2 | 2 | 0.00172884 | 972.46 | ||||
Citric acid | 77-92-9 | 40 | 0.000343376 | 193.147 | ||||
Water | 7732-18-5 | 60 | 0.00941487 | 5295.8 | ||||
Water | 7732-18-5 | 92.5 | 0.481774 | 270995 | ||||
Ammonium Chloride | 12125-02-9 | 1 | 0.000864419 | 486.23 | ||||
Ethanol | 64-17-5 | 2.8 | 0.000235968 | 132.731 | ||||
Didecyl dimethyl ammonium chloride | 7173-51-5 | 8 | 0.000671667 | 377.808 | ||||
prop-2-yn-1-0l | 107-19-7 | 5 | 0.00006777 | 38.121 | ||||
N-alkyl dimethyl benzyl ammonium chloride | 68424-85-1 | 5.3 | 0.000447497 | 251.714 | ||||
ethylene glycol | 107-21-1 | 40 | 0.00627658 | 3530.54 | ||||
Xylene | 1330-20-7 | 5 | 0.00006777 | 38.121 | ||||
Mineral oil/ light hydrotreated pet. distillate | 64742-47-8 | 20 | 0.0172884 | 9724.59 | ||||
propan-2-ol | 67-63-0 | 5 | 0.00006777 | 38.121 | ||||
fatty imidazoline | 61790-69-0 | 5 | 0.00006777 | 38.121 | ||||
Alkyl Phosphonic Acid | Proprietary | 10 | 0.00156915 | 882.634 | ||||
cololymer of 2-propenamide | 69418-26-4 | 30 | 0.0259326 | 14586.9 | ||||
KFEAC-30 | Keane | Iron Control | Acetic acid | 64-19-7 | 60 | 0.000515064 | 289.72 | |
Citric acid | 77-92-9 | 40 | 0.000343376 | 193.147 | ||||
Sand (Proppant) (lbs) | Keane | Proppant | Crystalline silica: Quartz (SiO2) | 14808-60-7 | 100 | 17.7365 | 9,976,640.0 |
For data sources see[5]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2015 | SENECA RESOURCES CO LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2016 | SENECA RESOURCES CO LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2017 | SENECA RESOURCES CO LLC | 575,340.58 | 228 | 0.00 | 0 | 0.00 | 0 |
2018 | SENECA RESOURCES CO LLC | 551,185.40 | 365 | 0.00 | 0 | 0.00 | 0 |
2019 | SENECA RESOURCES CO LLC | 402,992.08 | 365 | 0.00 | 0 | 0.00 | 0 |
For data sources see[6]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2015 | SENECA RESOURCES CO LLC | Drill Cuttings | 990.30 Tons | LANDFILL | 100361 |
2016 | SENECA RESOURCES CO LLC | Servicing Fluid | 49.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016 | SENECA RESOURCES CO LLC | Other Oil & Gas Wastes | 27.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2016 | SENECA RESOURCES CO LLC | Servicing Fluid | 97.44 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NW011 |
2016 | SENECA RESOURCES CO LLC | Other Oil & Gas Wastes | 110.56 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NW011 |
2016 | SENECA RESOURCES CO LLC | Produced Fluid | 194.44 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NW011 |
2017 | SENECA RESOURCES CO LLC | Other Oil & Gas Wastes | 140.01 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2017 | SENECA RESOURCES CO LLC | Produced Fluid | 56,694.02 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2017 | SENECA RESOURCES CO LLC | Produced Fluid | 8.16 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW005 |
2017 | SENECA RESOURCES CO LLC | Unused Fracturing Fluid Waste | 3.16 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123 |
2017 | SENECA RESOURCES CO LLC | Unused Fracturing Fluid Waste | 100.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW005 |
2017 | SENECA RESOURCES CO LLC | Produced Fluid | 11.00 Bbl | REUSE (AT WELL PAD) | |
2017 | SENECA RESOURCES CO LLC | Waste Water Treatment Sludge | 0.40 Tons | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW005 |
2018 | SENECA RESOURCES CO LLC | Produced Fluid | 154.00 Bbl | INJECTION DISPOSAL WELL | PAS2D025BELK |
2018 | SENECA RESOURCES CO LLC | Produced Fluid | 13.00 Bbl | REUSE (AT WELL PAD) | |
2018 | SENECA RESOURCES CO LLC | Produced Fluid | 16,105.51 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2018 | SENECA RESOURCES CO LLC | Other Oil & Gas Wastes | 11.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW005 |
2018 | SENECA RESOURCES CO LLC | Produced Fluid | 33.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW005 |
2018 | SENECA RESOURCES CO LLC | Synthetic Liner Materials | 0.36 Tons | LANDFILL | 100361 |
2018 | SENECA RESOURCES CO LLC | Other Oil & Gas Wastes | 75.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2019 | SENECA RESOURCES CO LLC | Synthetic Liner Materials | 0.07 Tons | LANDFILL | 100361 |
2019 | SENECA RESOURCES CO LLC | Produced Fluid | 43.33 Bbl | REUSE (AT WELL PAD) | |
2019 | SENECA RESOURCES CO LLC | Produced Fluid | 10,216.56 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2019 | SENECA RESOURCES CO LLC | Other Oil & Gas Wastes | 168.10 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2019 | SENECA RESOURCES CO LLC | Produced Fluid | 142.22 Bbl | INJECTION DISPOSAL WELL | PAS2D025BELK |
2019 | SENECA RESOURCES CO LLC | Other Oil & Gas Wastes | 22.00 Bbl | REUSE (AT WELL PAD) |
For data sources see[7]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2379752 | Primary Facility | 2015-06-17 | Routine/Complete Inspection | No Violations Noted | |
2386292 | Primary Facility | 2015-07-08 | Drilling/Alteration | No Violations Noted | At the time of inspection sunny sky, ~ 70° F. |
2389753 | Primary Facility | 2015-07-14 | Routine/Complete Inspection | No Violations Noted | |
2394753 | Primary Facility | 2015-07-24 | Drilling/Alteration | No Violations Noted | At the time of inspection sunny sky, ~ 75° F. |
2404946 | Primary Facility | 2015-09-02 | Routine/Complete Inspection | No Violations Noted | |
2438639 | Primary Facility | 2016-01-05 | Routine/Complete Inspection | No Violations Noted | |
2474093 | Primary Facility | 2016-04-12 | Routine/Complete Inspection | No Violations Noted | |
2539831 | Primary Facility | 2016-11-29 | Routine/Complete Inspection | No Violations Noted | |
2551565 | Primary Facility | 2017-01-11 | Routine/Complete Inspection | No Violations Noted | |
2553124 | Primary Facility | 2017-01-18 | Routine/Complete Inspection | No Violations Noted | |
2564038 | Primary Facility | 2017-02-22 | Routine/Complete Inspection | No Violations Noted | |
2568389 | Primary Facility | 2017-03-06 | Routine/Complete Inspection | No Violations Noted | |
2575257 | Primary Facility | 2017-03-27 | Routine/Complete Inspection | No Violations Noted | Well stimulation work continues on the Rich Valley C09Dwell pad. The C09D well pad is occupied by (9) Marcellus wells and (1) Utica well. Stimulation work today is a zipper frac on (2) Marcellus wells with (3) additional Marcellus wells remaining to be stimulated. Water is supplied to the C09D location via a 16 inch HDPE above ground temporary waterline from the Clermont water management facility. Fuel for engines on location is supplied by (2) fuel trucks spotted on secondary containment and fuel deliveries several times each day to replenish those (2) fuel trucks. (2) HCl trailers spotted on containment on the location, for acid treatment of perforations at the beginning of each stage. Secondary containment for water storage, light plants, fuel trucks, chemical additives and waste fluids were free of water or fluids spills. Well laterals are being stimulated generally in 190' stages with perforations on 60° spacings. At the completion of each well stimulation a kill plug is set approximately 100' ab |
2583535 | Primary Facility | 2017-04-11 | Routine/Complete Inspection | No Violations Noted | |
2610247 | Primary Facility | 2017-06-13 | Routine/Complete Inspection | No Violations Noted | |
2630959 | Primary Facility | 2017-08-15 | Routine/Complete Inspection | No Violations Noted | |
2654268 | Primary Facility | 2017-10-26 | Routine/Complete Inspection | No Violations Noted | Routine inspection of Seneca's CRV Pad C09-D on October 26, 2017. There are a total of 10 active wells located on this Marcellus well pad. Each well is labeled with the API and well permit number. Each well is connected to it own gas production unit (GPU) and any production water from the GPU is plumbed into 1 of 6 (400) BBL produced fluids tanks located onsite. There are a series of 20 frac tanks manifolded together along the Western border. These frac tanks are stationed on multiple layers of containment (see photo 2). Water within this secondary containment had a conductivity reading of 700 uS/cm. These frac tanks are being stationed onsite for a flowback that will occur in the near future from wells located on the CRV Pad C09-G. Water from the series of frac tanks will eventually be pumped to the Clermont Water Treatment Facility for reuse.
All PCSM BMPs have been installed. The site meets 70% uniform vegetation. A notice of termination (NOT) has not been approved for this well pad. I recommend submi |
2721852 | Primary Facility | 2018-04-23 | Routine/Complete Inspection | No Violations Noted | At the time of this inspection combustable gas was detected on the 9 5/8" x 5 1/2" annulus vent. No other combustable gas was detected. |
2809135 | Primary Facility | 2018-11-29 | Routine/Complete Inspection | No Violations Noted | Routine site inspection of Seneca Resources CRV Pad C09-D on November 29, 2018. There are a total of 10 producing Marcellus wells located on this well pad. Each well is labeled with the API and well permit number. Each well is connected to it own gas production unit (GPU) and any production water from the GPU is plumbed into 1 of 5 (400) BBL produced fluids tanks located onsite.
All PCSM BMPs have been installed. In previous inspections I have mentioned that the site meets 70% uniform vegetation, but today everything was snow and/or ice covered. A notice of termination (NOT) has not been approved for this ESCGP to date. I recommend submitting an NOT form next Spring/Summer 2019. The pad remains at full built-out of 235' x 550'. No violations noted. |
2825353 | Primary Facility | 2019-01-10 | Routine/Complete Inspection | No Violations Noted | At the time of this inspection this well was in production. A digital gauge on the well head assembly was showing 437 psi (pounds per square inch). The annulus casings 20 x 13, the 13 x 9 and the 9 x 5 were vented to surface. Combustible gas , 100% LEL (lower explosion limit) and 76% Methane was detected on the 9 x 5 annulus vent at this inspection. No violations were noted at this inspection. |
For data sources see[8]