X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-027-21503

Well Details

Well ID: 37-027-21503
Loading map...
Country: United States
State: Pennsylvania
County: Centre
Municipality: Burnside Township
Operator Name: EXCO RESOURCES PA LLC
Well Pad ID: 148765
Farm/Lease Name: LITKE P-1 16H
License Status:
Spud Date:
Permit Date: 2009-01-27
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: Yes
Latitude: 41.073915
Longitude: -77.980994

For data sources see[1][2][3]

Well History

Date Event
2009-01-27 New Permit Application
2010-01-08 Permit Renewal Application
2010-03-23 Performed Spud Operation
2010-07-13 Drilling Completion
2010-09-14 Perforation
2012-07-23 DEVIATED

For data sources see[4]


Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2009 EXCO RESOURCES PA INC 0.00 0 0.00 0 0.00 0
2010 EXCO RESOURCES PA INC 0.00 0 0.00 0 0.00 0
2011 EXCO RESOURCES PA INC 375,244.00 307 0.00 0 0.00 0
2012 EXCO RESOURCES PA LLC 292,170.00 366 0.00 0 0.00 0
2013 EXCO RESOURCES PA LLC 218,874.00 365 0.00 0 0.00 0
2014 EXCO RESOURCES PA LLC 186,170.00 365 0.00 0 0.00 0
2015 EXCO RESOURCES PA LLC 165,482.00 365 0.00 0 0.00 0
2016 EXCO RESOURCES PA LLC 154,061.00 364 0.00 0 0.00 0
2017 EXCO RESOURCES PA LLC 144,234.00 365 0.00 0 0.00 0
2018 EXCO RESOURCES PA LLC 136,317.00 364 0.00 0 0.00 0
2019 EXCO RESOURCES PA LLC 127,123.00 365 0.00 0 0.00 0

For data sources see[5]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2010 EXCO RESOURCES PA INC Produced Fluid 100.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PAS2D205BCLE
2010 EXCO RESOURCES PA INC Drilling Fluid Waste 336.90 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0091472
2010 EXCO RESOURCES PA INC Produced Fluid 259.90 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0101508
2010 EXCO RESOURCES PA INC Produced Fluid 785.70 Bbl PUBLIC SEWAGE TREATMENT PLANT PA0028207
2010 EXCO RESOURCES PA INC Drilling Fluid Waste 196.50 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE 301353
2010 EXCO RESOURCES PA INC Drilling Fluid Waste 327.50 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0095273
2010 EXCO RESOURCES PA INC Drilling Fluid Waste 109.00 Bbl INJECTION DISPOSAL WELL 34-155-23203
2011 EXCO RESOURCES PA INC Produced Fluid 223.78 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR119
2011 EXCO RESOURCES PA INC Produced Fluid 1,146.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0101508
2011 EXCO RESOURCES PA INC Produced Fluid 307.28 Bbl INJECTION DISPOSAL WELL 34-059-24067
2011 EXCO RESOURCES PA INC Produced Fluid 466.34 Bbl REUSE OTHER THAN ROAD SPREADING
2011 EXCO RESOURCES PA INC Produced Fluid 95.19 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE EPA ID: 748-163
2011 EXCO RESOURCES PA INC Produced Fluid 141.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0095443
2011 EXCO RESOURCES PA INC Produced Fluid 2,595.54 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PAS2D205BCLE
2011 EXCO RESOURCES PA INC Fracing Fluid Waste 14,571.00 Bbl REUSE OTHER THAN ROAD SPREADING
2011 EXCO RESOURCES PA INC Produced Fluid 330.41 Bbl STORAGE PENDING DISPOSAL OR REUSE
2011 EXCO RESOURCES PA INC Produced Fluid 1,745.30 Bbl INJECTION DISPOSAL WELL 34-119-27350
2011 EXCO RESOURCES PA INC Produced Fluid 783.00 Bbl PUBLIC SEWAGE TREATMENT PLANT PA0028207
2011 EXCO RESOURCES PA INC Produced Fluid 115.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0095273
2012 EXCO RESOURCES PA LLC Produced Fluid 2,030.17 Bbl INJECTION DISPOSAL WELL PAS2D205BCLE
2012 EXCO RESOURCES PA LLC Produced Fluid 105.21 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW008
2012 EXCO RESOURCES PA LLC Produced Fluid 103.00 Bbl REUSE OTHER THAN ROAD SPREADING
2012 EXCO RESOURCES PA LLC Produced Fluid 2,220.39 Bbl INJECTION DISPOSAL WELL 34-119-27350
2012 EXCO RESOURCES PA LLC Produced Fluid 50.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0095273
2013 EXCO RESOURCES PA LLC Produced Fluid 188.71 Bbl STORAGE PENDING DISPOSAL OR REUSE
2013 EXCO RESOURCES PA LLC Produced Fluid 2,737.68 Bbl INJECTION DISPOSAL WELL PAS2D205BCLE
2014 EXCO RESOURCES PA LLC Produced Fluid 2,774.59 Bbl INJECTION DISPOSAL WELL PAS2D205BCLE
2015 EXCO RESOURCES PA LLC Produced Fluid 2,307.70 Bbl INJECTION DISPOSAL WELL PAS2D205BCLE
2016 EXCO RESOURCES PA LLC Produced Fluid 2,219.60 Bbl INJECTION DISPOSAL WELL PAS2D205BCLE
2016 EXCO RESOURCES PA LLC Other Oil & Gas Wastes 5.00 Bbl INJECTION DISPOSAL WELL PAS2D205BCLE
2017 EXCO RESOURCES PA LLC Produced Fluid 2,358.80 Bbl INJECTION DISPOSAL WELL PAS2D205BCLE
2018 EXCO RESOURCES PA LLC Produced Fluid 387.40 Bbl INJECTION DISPOSAL WELL 34-007-21847
2018 EXCO RESOURCES PA LLC Produced Fluid 1,438.00 Bbl INJECTION DISPOSAL WELL PAS2D205BCLE
2018 EXCO RESOURCES PA LLC Produced Fluid 106.60 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2019 EXCO RESOURCES PA LLC Produced Fluid 1,631.60 Bbl INJECTION DISPOSAL WELL PAS2D205BCLE

For data sources see[6]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1874278 Primary Facility 2010-04-01 Drilling/Alteration No Violations Noted Setting 13 3/8" casing
1875255 Primary Facility 2010-03-30 Drilling/Alteration No Violations Noted -Pad also houses Litke P-1 Wells 14H and 15H and was inspected previously on 3/24/2010. E&S plan remains on site and site ID sign reflects information for the 16H well.
1894254 Primary Facility 2010-06-25 Drilling/Alteration No Violations Noted 8 3/4" hole drilled to 3282'. Rig tripping out to fix broken wireline.
1919004 Primary Facility 2010-10-08 Complaint Inspection No Violations Noted
1921652 Primary Facility 2010-10-19 Routine/Complete Inspection No Violations Noted Well completed not in production, bubbles in water around well head.
1929820 Primary Facility 2010-11-02 Routine/Complete Inspection No Violations Noted
1938337 Primary Facility 2010-12-20 Compliance Evaluation Viol(s) Noted & Immediately Corrected
1938742 Primary Facility 2010-12-16 Routine/Complete Inspection No Violations Noted
1946352 Primary Facility 2010-12-29 Compliance Evaluation Outstanding Violations - No Viols Req'd
1948258 Primary Facility 2011-01-06 Compliance Evaluation Outstanding Violations - No Viols Req'd
1952932 Primary Facility 2011-01-19 Routine/Complete Inspection No Violations Noted
1966746 Primary Facility 2011-03-08 Routine/Complete Inspection No Violations Noted
1971166 Primary Facility 2011-03-10 Routine/Complete Inspection No Violations Noted
1980610 Primary Facility 2011-04-21 Routine/Complete Inspection No Violations Noted
2001237 Primary Facility 2011-07-19 Routine/Complete Inspection No Violations Noted
2002815 Primary Facility 2011-07-27 Routine/Complete Inspection No Violations Noted
2009023 Primary Facility 2011-08-12 Routine/Complete Inspection No Violations Noted
2012604 Primary Facility 2011-08-17 Routine/Complete Inspection No Violations Noted
2020200 Primary Facility 2011-09-14 Routine/Complete Inspection No Violations Noted
2023023 Primary Facility 2011-09-26 Routine/Complete Inspection No Violations Noted
2065818 Primary Facility 2012-03-28 Routine/Complete Inspection No Violations Noted
2085856 Primary Facility 2012-05-25 Routine/Complete Inspection No Violations Noted
2188601 Primary Facility 2013-07-30 Routine/Complete Inspection No Violations Noted
2317937 Primary Facility 2014-10-28 Routine/Complete Inspection No Violations Noted
2555842 Primary Facility 2017-01-23 Routine/Complete Inspection No Violations Noted
2574110 Primary Facility 2017-02-21 Routine/Complete Inspection No Violations Noted Routine inspection of unconvnetional well in production. No violations noted at time of inspection.
2686124 Primary Facility 2018-01-24 Routine/Complete Inspection No Violations Noted The weather is 30 Deg. F and cloudy and windy at time of inspection. Routine inspection of EXCO Resources PA LLC., Litke P-1, Well # 16H on January 24, 2018.

There are 3 producing wells on this pad. Annulus is closed and not vented at time of inspection. 0% combustible gas was detected at the annulus or in the area immediately surrounding the well. Wellsite looks neat and well organized. No violations noted. DEP Representative ¿ Ulyana Trynovich, Oil and Gas Inspector.

2692095 Primary Facility 2018-02-01 Routine/Complete Inspection No Violations Noted
2705841 Primary Facility 2018-03-09 Routine/Complete Inspection No Violations Noted Routine site inspection at EXCO Resources LLC Litke 1 Pad on March 9, 2018.

The site sign, drilling permits, weekly E&S log, PPC plan, emergency response plan (ERP), and work description of the pad and impoundments were found onsite. Please note that the PPC plan and ERP are dated June 2013 and February 2014 respectively. The Department recommends that the operator update both plans and place a copy onsite.

There are 3 drilled and producing Marcellus wells located on the pad. All well cellars are full of frozen water and each well is properly labeled. There are (3) 400 bbl produced fluids tanks stationed in secondary containment on this pad. Water within containment was frozen. No signs of leaks from the containment were observed. Each tank was labeled.

Part of the well pad has been partially restored. In addition, both impoundments have been fully restored. No E&S issues were observed.

2741688 Primary Facility 2018-06-13 Routine/Complete Inspection No Violations Noted Routine site inspection at EXCO Resources LLC Litke 1 Pad on June 13, 2018.

The site sign, drilling permits, weekly E&S log, PPC plan, emergency response plan (ERP), and work description of the pad and impoundments were found onsite. Please note that the PPC plan and ERP are dated June 2013 and February 2014 respectively. As noted in my March 2018 inspection report, the Department recommends that the operator update both plans and place a copy onsite.

There are 3 drilled and producing Marcellus wells located on the pad. All well cellars are filled in with gravel and each well is properly labeled. There are (3) 400 bbl produced fluids tanks stationed in secondary containment on this pad. Water within containment was 256 uS/cm. No signs of leaks from the containment were observed. Each tank was labeled.

Part of the well pad has been partially restored. In addition, both impoundments have been fully restored. No E&S issues were observed.

2841921 Primary Facility 2019-02-19 Routine/Complete Inspection No Violations Noted The weather is 32 Deg. F and sunny at the time of inspection. Routine inspection of EXCO Resources PA LLC., Litke P-1 Pad, well # 16H on February 19, 2019.

This well is active and producing. Annulus vents are not visible, covered by snow. Pressure gauges haven't been installed for this well. 0% combustible gas was detected in the area immediately surrounding the well. Production processing equipment includes ¿ 4 production water tanks, 3 gas processing units; measurement equipment - orifice meter stations. No violations are noted at time of inspection. DEP Representative - Ulyana Trynovich, Oil and Gas Inspector.

2853277 Primary Facility 2019-03-13 Routine/Complete Inspection No Violations Noted Department representative Sue Herzing conducted a routine site inspection at EXCO Resources (PA) LLC Litke Pad 1 on March 13, 2019. No one was onsite during the inspection.

There are 3 drilled and producing Marcellus wells located on the pad. All well cellars are full of gravel. There are (3) 400 bbl produced fluids tanks stationed in secondary containment on this pad. Water within he secondary containment was frozen. No signs of leaks from the secondary containment were observed. Each tank was properly labeled.

Part of the well pad has been partially restored. The restored portion of the well pad and areas surrounding it have reached 70% vegetative cover. In addition, two (3.16 MG) impoundments have been fully restored and exceed 70% uniform, perennial, vegetative cover. No E&S issues were observed.

No violations noted.

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
1938337 601709 12/20/2010 2010-12-20 78.54* - Failure to properly control or dispose of industrial or residual waste to prevent pollution of the waters of the Commonwealth. Environmental Health & Safety Failure of a temperature control and pressure relief value caused the release of 10-15 gals of ethylene glycol to the ground covering an area of approximately 4000 sqft

For data sources see[7]

References