Well Details

Well ID: 37-027-21608
Loading map...
Country: United States
State: Pennsylvania
County: Centre
Municipality: Burnside Township
Operator Name: EXCO RESOURCES PA LLC
Well Pad ID: 147986
Farm/Lease Name: CONFER P-32
License Status: INACTIVE
Spud Date: 2010-08-21
Permit Date: 2010-04-20
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.084497
Longitude: -78.019817

For data sources see[1][2][3]

Well History

Date Event
DEVIATED
2010-04-20 New Permit Application
2010-08-21 Performed Spud Operation
2010-10-20 Drilling Completion
2019-08-16 Inactive Well Request Granted

For data sources see[4]


Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2010 EXCO RESOURCES PA INC 0.00 0 0.00 0 0.00 0
2011 EXCO RESOURCES PA INC 0.00 0 0.00 0 0.00 0
2012 EXCO RESOURCES PA LLC 0.00 0 0.00 0 0.00 0
2013 EXCO RESOURCES PA LLC 0.00 0 0.00 0 0.00 0
2014 EXCO RESOURCES PA LLC 0.00 0 0.00 0 0.00 0
2015 EXCO RESOURCES PA LLC 0.00 0 0.00 0 0.00 0
2016 EXCO RESOURCES PA LLC 0.00 0 0.00 0 0.00 0
2017 EXCO RESOURCES PA LLC 0.00 0 0.00 0 0.00 0
2019 EXCO RESOURCES PA LLC 0.00 0 0.00 0 0.00 0

For data sources see[5]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2010 EXCO RESOURCES PA INC Drilling Fluid Waste 703.30 Bbl REUSE OTHER THAN ROAD SPREADING
2011 EXCO RESOURCES PA INC Drilling Fluid Waste 585.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR119
2011 EXCO RESOURCES PA INC Drilling Fluid Waste 1,651.00 Bbl REUSE OTHER THAN ROAD SPREADING
2012 EXCO RESOURCES PA LLC Produced Fluid 220.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0095273

For data sources see[6]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1919975 Primary Facility 2010-10-07 Drilling/Alteration No Violations Noted Patterson 257 is drilling 8 3/4" hole @ 5417
1921657 Primary Facility 2010-10-19 Drilling/Alteration No Violations Noted Patterson 257 drilling 8.75" hole laterally @ 13,287'
1967408 Primary Facility 2011-03-08 Routine/Complete Inspection No Violations Noted
1977714 Primary Facility 2011-03-18 Routine/Complete Inspection No Violations Noted
1977786 Primary Facility 2011-03-28 Routine/Complete Inspection No Violations Noted
1980690 Primary Facility 2011-04-26 Routine/Complete Inspection No Violations Noted
1992902 Primary Facility 2011-06-17 Routine/Complete Inspection No Violations Noted
2001308 Primary Facility 2011-07-22 Routine/Complete Inspection No Violations Noted
2022973 Primary Facility 2011-09-23 Routine/Complete Inspection No Violations Noted
2046881 Primary Facility 2012-02-07 Routine/Complete Inspection No Violations Noted
2186279 Primary Facility 2013-07-23 Routine/Complete Inspection No Violations Noted
2253387 Primary Facility 2014-03-13 Routine/Complete Inspection No Violations Noted
2479857 Primary Facility 2016-04-12 Complaint Inspection No Violations Noted Inspection of non conventional well from AMD complaint. No violations noted.
2538200 Primary Facility 2016-11-07 Routine/Complete Inspection No Violations Noted Routine inspection of an unconventional well on inactive status. No violations noted at time of inspection.
2705588 Primary Facility 2018-02-21 Routine/Complete Inspection No Violations Noted The weather is 70 Deg. F, cloudy and windy at time of inspection. Routine inspection of EXCO Resources PA LLC., Confer P-32 Pad, Well # 223H on February 21, 2018. There are 2 producing wells and 3 granted regulatory inactive status on this pad.

This well is inactive and shut in. Annulus vent is open and vented. 100% LEL and 60% combustible gas was detected at the 9-5/8" x 5-1/2" annulus vent. No obvious concerns or violations are noted at time of inspection. Wellsite looks neat and well organized. Regulatory inactive status expires on June 9, 2019. EXCO Resources, LLC. Representative ¿ Sam Unch, Production Operator. DEP Representative - Ulyana Trynovich, Oil and Gas Inspector.

2705896 Primary Facility 2018-03-09 Routine/Complete Inspection No Violations Noted Routine site inspection at EXCO Resources LLC Confer Pad 32 on March 9, 2018. No one was onsite during my inspection.

The site sign, ESCGP, Emergency Response Plan, PPC Plan, and weekly E&S inspection log were onsite and available for review.

The pad and surrounding areas were snow covered. PCSMs have been installed at the well pad and along the access road.

There are a total of 5 Marcellus wells spud on this well pad. Wells 027-21609 and 027-21610 are currently producing. The other three wells (027-21595, 027-21608, and 027-21611)are in regulatory inactive status. All wells are properly tagged. There are 2 GPUs and and 2 produced fluids tanks stationed onsite. Produced fluids tanks are stationed in secondary containment and are properly labeled. Water in produced fluids containment was frozen.

2822649 Primary Facility 2019-01-04 Routine/Complete Inspection No Violations Noted Routine site inspection at EXCO Resources LLC Confer Pad 32 on January 4, 2019. No one was onsite during my inspection.

The site sign, ESCGP, Emergency Response Plan, PPC Plan, and weekly E&S inspection log were onsite and available for review.

PCSMs have been installed at the well pad and along the access road. A 70% uniform vegetative status has been achieved. I recommend removing the fabric liner of the compost sock and submitting a notice of termination (weather permitting). No E&S issues were observed.

There are a total of 5 Marcellus wells spud on this well pad. Wells 027-21609 and 027-21610 are currently producing. The other three wells (027-21595, 027-21608, and 027-21611) are in regulatory inactive status. All wells are properly tagged. There is one dual GPU and 2 (400) bbl. produced fluids tanks stationed onsite. Produced fluids tanks are stationed in secondary containment and are properly labeled. Water in produced fluids containment was frozen.

No violations noted.

For data sources see[7]