X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-033-26673

Well Details

Well ID: 37-033-26673
Loading map...
Country: United States
State: Pennsylvania
County: Clearfield
Municipality: Goshen Township
Operator Name: GREYLOCK CONVENTIONAL LLC
Well Pad ID: 146134
Farm/Lease Name: WHITETAIL 1
License Status: ACTIVE
Spud Date:
Permit Date: 2008-06-13
Well Type: GAS
Unconventional Well: Y
Configuration: Vertical Well
Conservation: Yes
Latitude: 41.121268
Longitude: -78.342497

For data sources see[1][2][3]

Well History

Date Event
2008-06-13 New Permit Application
2009-01-07 Performed Spud Operation
2009-01-23 Drilling Completion
2009-03-12 Perforation
2009-10-22 NEWLY DRILLED

For data sources see[4]


Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2008 ENERGY CORP OF AMER 0.00 0 0.00 0 0.00 0
2009 ENERGY CORP OF AMER 10494.00 266 0.00 0 0.00 0
2010 ENERGY CORP OF AMER 7,067.00 343 0.00 0 0.00 0
2011 ENERGY CORP OF AMER 445.00 31 0.00 0 0.00 0
2012 ENERGY CORP OF AMER 19.00 182 0.00 0 0.00 0
2013 ENERGY CORP OF AMER 239.00 165 0.00 0 0.00 0
2014 ENERGY CORP OF AMER 22.00 129 0.00 0 0.00 0
2015 ENERGY CORP OF AMER 0.00 0 0.00 0 0.00 0
2016 ENERGY CORP OF AMER 0.00 0 0.00 0 0.00 0
2017 ENERGY CORP OF AMER 12.00 2 0.00 0 0.00 0
2018 GREYLOCK CONVENTIONAL LLC 15.00 1 0.00 0 0.00 0
2019 GREYLOCK CONVENTIONAL LLC 5.00 1 0.00 0 0.00 0

For data sources see[5]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2009 ENERGY CORP OF AMER Brine 480.00 Bbl Brine or Industrial Waste Treatment Plt PA0091472
2010 ENERGY CORP OF AMER Produced Fluid 240.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0091472
2010 ENERGY CORP OF AMER Produced Fluid 80.00 Bbl REUSE OTHER THAN ROAD SPREADING
2014 ENERGY CORP OF AMER Produced Fluid 110.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016 ENERGY CORP OF AMER Produced Fluid 10.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011

For data sources see[6]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1763125 Primary Facility 2009-01-07 Drilling/Alteration No Violations Noted rigging up, prognosis estimates TD @ 9,000', site in HQ watershed, no e/s problems
1764653 Primary Facility 2009-01-16 Routine/Complete Inspection No Violations Noted drilling/E&S ok/pit ok/ID&plan ok
1765323 Primary Facility 2009-01-16 Drilling/Alteration No Violations Noted drilling at 4,700', pit ok
1768353 Primary Facility 2009-02-04 Routine/Complete Inspection No Violations Noted drilling in progress/E&S ok/pit ok/ID ok
1793017 Primary Facility 2009-04-03 Drilling/Alteration Violation(s) Noted 1) Failure to minimize accelerated erosion- Fill side of pad was not stabilized, recent heavy rains caused erosion to such an extent that primary sediment fence was failing
1793925 Primary Facility 2009-04-06 Follow-up Inspection Violation(s) Noted The following BMPs had been installed since inspection on 4/3/2009:
1793968 Primary Facility 2009-04-14 Follow-up Inspection Outstanding Violations - No Viols Req'd 1) company seeded and heavily mulched fill side of well pad. Erosion stabilized.
1804906 Primary Facility 2009-06-01 Routine/Complete Inspection Outstanding Violations - No Viols Req'd Site being actively restored. BMPs have been maintained. Pit filled in No E&S issues
1811359 Primary Facility 2009-07-06 Routine/Complete Inspection Violation(s) Noted Site contains multiple areas where channels are beginning to cut through slopes, both on pad and from access road. Seed and mulch are in place, but vegetation is sparse. BMPs are starting to be overrun with sediments
1826585 Primary Facility 2009-09-08 Follow-up Inspection No Violations Noted Inspection revealed the following:
1829628 Primary Facility 2009-09-11 Follow-up Inspection Outstanding Violations - No Viols Req'd Inspection revealed the following:
1830130 Primary Facility 2009-09-23 Follow-up Inspection Outstanding Violations - No Viols Req'd On-site meeting with Jim Lipsie of EAE, Contractor, Randy Lunger and one co-worker of Dan Beck Construction, and Well tender, Dan Stiver. Focused meeting on slope that continues to erode and can't sustain vegetation. Contractor proposed terracing the slope, spreading large amounts of lime and seeding with a high winter variety seed mix. BMPs will be cleaned up and replaced where necessary. Mr. Lipsie has to run suggestions through his boss and will get back to me as soon as possible with final plan. it has been suggested that the company have a soil test conducted, they use an engineer to design new contruction and create an effective inspection/maintenance schedule for BMPs.
1833320 Primary Facility 2009-10-06 Follow-up Inspection Outstanding Violations - No Viols Req'd -Received call from Jim Lipsie on morning of September 28, 2009. Changes to site have been approved and work on site should begin by end of week.
1837965 Primary Facility 2009-10-15 Follow-up Inspection Outstanding Violations - No Viols Req'd -Earthmoving equipment has been staged on-site
1837989 Primary Facility 2009-10-23 Follow-up Inspection Outstanding Violations - No Viols Req'd -Received call from Jim Lipsie on 22OCT2009: new silt fence in place, ponds installed, and approximately 16 tons of lime applied. Seeding and mulching will be done within the next week
1838766 Primary Facility 2009-10-27 Follow-up Inspection Viol(s) Noted & Immediately Corrected -recent heavy rain caused additional slope failure
1843556 Primary Facility 2009-11-05 Follow-up Inspection No Violations Noted -Since last inspection all repairs to compromised BMPs have been made. Silt fence is installed and working properly, the water bar and erosion ditch that was formed in the curve in the lower end of the access road has been rock lined and sediment trap cleaned out.
1849040 Primary Facility 2009-12-09 Routine/Complete Inspection No Violations Noted Inspection conducted with WQS Jessica Miller.
1849896 Primary Facility 2009-12-09 Routine/Complete Inspection No Violations Noted - Site covered in approximately 5 inches of snow.
1869811 Primary Facility 2010-03-15 Routine/Complete Inspection No Violations Noted - Site ID sign, and E&S plan remain on site, well is complete and tag in place
1876802 Primary Facility 2010-04-06 Routine/Complete Inspection No Violations Noted - Vegetation continues to grown back and is at about about 30% uniform coverage. There are a few bare spots along the terrace and below the slope that may need reapplication of seed and mulch.
1969615 Primary Facility 2011-05-02 Compliance Evaluation No Violations Noted
1972354 Primary Facility 2011-05-12 Compliance Evaluation No Violations Noted
2466420 Primary Facility 2016-03-21 Site Restoration Violation(s) Noted
2508614 Primary Facility 2016-08-08 Follow-up Inspection No Violations Noted
2614090 Primary Facility 2017-07-11 Administrative/File Review Violation(s) Noted Administrative Inspection Record created for the purpose of entering Enforcement Record for failure to plug an abandoned well.

UPDATE: Operator reported production on the well for two days in October 2017 to demonstrate that the well is capable of producing. VIOL closed 12/15/2017. ~CMB~

2668434 Primary Facility 2017-12-01 Routine/Complete Inspection No Violations Noted Routine inspection of Energy of America Corporation's Whitetail Rod and Gun Club #1 well site (033-26673) on December 1, 2017. The site has been restored and a well site restoration report has been approved by the Department; approved in March 2016.

Due to the original pad size no ESCGP was issued because the pad construction was under the 5 acre threshold. There is one vertical Marcellus well remaining (033-26673) that is in production. I did not observe a well tag on the well head. I recommend tagging the well per 78a regulations. A produced fluids tank is stationed within an unlined, earthen secondary containment berm.

The restored area is well vegetated. No E&S issues were observed during my inspection.

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
1793017 561514 04/03/2009 2009-04-03 102.4 - Failure to minimize accelerated erosion, implement E&S plan, maintain E&S controls. Failure to stabilize site until total site restoration under OGA Sec 206(c)(d) Environmental Health & Safety Failure to implement E&S plan, 102.4(b)(1), 102.11(a), 102.22(a)&(b) viols. CACP finalized 11/17/09. MBC 11/18/2009
1793017 561515 04/03/2009 2009-04-03 78.56FRBRD - Failure to maintain 2' freeboard in an impoundment Administrative Failure to maintain at least 2 ft of freeboard. CACP finalized 11/17/09. MBC 11/18/2009
1793017 561517 04/03/2009 2009-04-03 401 CSL - Discharge of pollutional material to waters of Commonwealth. Environmental Health & Safety Sediments discharged to Little Trout Run. CACP finalized 11/17/09. MBC 11/18/2009
1793017 575949 04/03/2009 2009-04-03 601.101 - O&G Act 223-General. Used only when a specific O&G Act code cannot be used Administrative Failure to implement E&S plan, 78.53 viol. CACP finalized 11/17/09. MBC 11/18/2009
1793925 575947 04/06/2009 2009-04-06 102.4 - Failure to minimize accelerated erosion, implement E&S plan, maintain E&S controls. Failure to stabilize site until total site restoration under OGA Sec 206(c)(d) Environmental Health & Safety Failure to implement E&S plan, 102.4(b)(1), 102.11(a), 102.22(a)&(b) viols. CACP finalized 11/17/09. MBC 11/18/2009
1793925 575948 04/06/2009 2009-04-06 601.101 - O&G Act 223-General. Used only when a specific O&G Act code cannot be used Administrative Failure to implement E&S plan, 78.53 viol. CACP finalized 11/17/09. MBC 11/18/2009
1793925 575950 04/06/2009 2009-04-06 78.56FRBRD - Failure to maintain 2' freeboard in an impoundment Administrative Failure to maintain at least 2 ft of freeboard. CACP finalized 11/17/09. MBC 11/18/2009
1811359 566677 07/06/2009 2009-07-06 102.4 - Failure to minimize accelerated erosion, implement E&S plan, maintain E&S controls. Failure to stabilize site until total site restoration under OGA Sec 206(c)(d) Environmental Health & Safety See Insp ID 1843556, past viols corrected. MBC 11/18/2009
1838766 574336 10/27/2009 2009-10-27 102.4 - Failure to minimize accelerated erosion, implement E&S plan, maintain E&S controls. Failure to stabilize site until total site restoration under OGA Sec 206(c)(d) Environmental Health & Safety See Insp ID 1843556, all past viols corrected. MBC 11/18/2009
2466420 754771 2016-03-21 2016-08-08 78.56(a)1 Environmental Health & Safety
2466420 754774 2016-03-21 2016-08-08 91.34A Environmental Health & Safety
2614090 791128 2017-07-11 2017-12-15 78a91(a) Environmental Health & Safety The Whitetail 1 well was drilled to total permitted depth on January 29, 2009 under the authorization of well permit number 033-26673. No production has been reported for the Whitetail 1 well since December 2014. The well is therefore considered "abandoned" in accordance with Section 3203 of the 2

Penalties Applied

Violation ID Penalty ID Penalty Code Penalty Status Penalty Date Enforcement Date Penalty Amount Amount Collected
561514 245831 NOV - Notice of Violation Comply/Closed 2009-11-17
561514 252556 CACP - Consent Assessment of Civil Penalty Comply/Closed 2009-11-17 2009-11-17 $3,500.00 $3,500.00
561515 245831 NOV - Notice of Violation Comply/Closed 2009-11-17
561515 252556 CACP - Consent Assessment of Civil Penalty Comply/Closed 2009-11-17 2009-11-17 $3,500.00 $3,500.00
561517 245831 NOV - Notice of Violation Comply/Closed 2009-11-17
561517 252556 CACP - Consent Assessment of Civil Penalty Comply/Closed 2009-11-17 2009-11-17 $3,500.00 $3,500.00
575949 252556 CACP - Consent Assessment of Civil Penalty Comply/Closed 2009-11-17 2009-11-17 $3,500.00 $3,500.00
575947 252556 CACP - Consent Assessment of Civil Penalty Comply/Closed 2009-11-17 2009-11-17 $3,500.00 $3,500.00
575948 252556 CACP - Consent Assessment of Civil Penalty Comply/Closed 2009-11-17 2009-11-17 $3,500.00 $3,500.00
575950 252556 CACP - Consent Assessment of Civil Penalty Comply/Closed 2009-11-17 2009-11-17 $3,500.00 $3,500.00
754771 341374 NOV - Notice of Violation 2016-08-08
754771 359690 COA - Consent Order and Agreement COMP - Completed 2017-12-28 $1,687,500.00 $1,688,500.00
754774 341374 NOV - Notice of Violation 2016-08-08
754774 359690 COA - Consent Order and Agreement COMP - Completed 2017-12-28 $1,687,500.00 $1,688,500.00
791128 356108 NOV - Notice of Violation 2017-12-15

For data sources see[7]

References