X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-035-21274

Well Details

Well ID: 37-035-21274
Loading map...
Country: United States
State: Pennsylvania
County: Clinton
Municipality: East Keating Township
Operator Name: FRONTIER NATURAL RESOURCES
Well Pad ID: 149585
Farm/Lease Name: WINNER 6 6HG
License Status:
Spud Date:
Permit Date: 2012-01-19
Well Type: GAS
Unconventional Well: Y
Configuration: Vertical Well
Conservation: No
Latitude: 41.243861
Longitude: -77.956828

For data sources see[1][2][3]

Well History

Date Event
2012-01-19 New Permit Application
2012-01-26 Performed Spud Operation

For data sources see[4]


Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2012 ENERPLUS RES USA CORP 0.00 0 0.00 0 0.00 0
2013 ENERPLUS RES USA CORP 0.00 0 0.00 0 0.00 0
2014 ENERPLUS RES USA CORP 0.00 0 0.00 0 0.00 0
2015 FRONTIER NATURAL RESOURCES 0.00 0 0.00 0 0.00 0
2016 FRONTIER NATURAL RESOURCES 0.00 0 0.00 0 0.00 0
2017 FRONTIER NATURAL RESOURCES 0.00 0 0.00 0 0.00 0
2019 FRONTIER NATURAL RESOURCES 0.00 0 0.00 0 0.00 0

For data sources see[5]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2038308 Primary Facility 2012-01-31 Routine/Complete Inspection Viol(s) Noted & Immediately Corrected
2047027 Primary Facility 2012-02-10 Routine/Complete Inspection No Violations Noted
2053309 Primary Facility 2012-03-21 Incident- Response to Accident or Event Violation(s) Noted
2053418 Primary Facility 2012-03-22 Follow-up Inspection Outstanding Violations - No Viols Req'd
2058289 Primary Facility 2012-03-06 Routine/Complete Inspection No Violations Noted
2069228 Primary Facility 2012-04-11 Follow-up Inspection Outstanding Violations - No Viols Req'd
2077323 Primary Facility 2012-05-10 Follow-up Inspection Outstanding Violations - No Viols Req'd
2093789 Primary Facility 2012-07-18 Routine/Complete Inspection No Violations Noted
2095173 Primary Facility 2012-07-26 Routine/Complete Inspection No Violations Noted
2098617 Primary Facility 2012-08-03 Routine/Complete Inspection No Violations Noted
2109033 Primary Facility 2012-10-09 Routine/Complete Inspection No Violations Noted
2161510 Primary Facility 2013-04-26 Routine/Complete Inspection No Violations Noted
2181843 Primary Facility 2013-07-09 Routine/Complete Inspection No Violations Noted
2399273 Primary Facility 2015-08-10 Routine/Complete Inspection No Violations Noted
2509438 Primary Facility 2016-07-29 Routine/Complete Inspection No Violations Noted
2614100 Primary Facility 2017-07-11 Administrative/File Review Violation(s) Noted Administrative Inspection Record created for the purpose of entering Enforcement Record for failure to plug an abandoned well.

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
2038308 630815 01/31/2012 2012-01-31 78.61A - Improper pit disposal of drill cuttings from above the casing seat Administrative Drill cuttings from the conductor drilling were disposed of directly onto the well pad.
2038308 630816 01/31/2012 2012-01-31 SWMA301 - Failure to properly store, transport, process or dispose of a residual waste. Environmental Health & Safety Disposal of residual waste in the form of drill cuttings directly to the surface of the well pad
2053309 635218 03/21/2012 2012-03-21 402CSL - Failure to adopt pollution prevention measures required or prescribed by DEP by handling materials that create a danger of pollution. Environmental Health & Safety The release of treated flowback onto a cement stabilized pad with under drains presents teh possibility of contamination to waters flowing under teh well pad.
2053309 635219 03/21/2012 2012-03-21 78.54* - Failure to properly control or dispose of industrial or residual waste to prevent pollution of the waters of the Commonwealth. Environmental Health & Safety Failure to contain treated flowback in Baker tanks and within teh containment around the tanks
2053309 635220 03/21/2012 2012-03-21 SWMA301 - Failure to properly store, transport, process or dispose of a residual waste. Environmental Health & Safety Failure to adequately contain residual waste within the storage tanks and containment
2614100 791129 2017-07-11 78a91(a) Environmental Health & Safety The Winner 6 well was spud January 26, 2012 and was drilled to a depth necessary to set conductor casing under the authorization of well permit number 035-21274. The well permit for 035-21274 expired January 19, 2013. The well remains a conductor and has had no drilling activity since 2012. The w

Penalties Applied

Violation ID Penalty ID Penalty Code Penalty Status Penalty Date Enforcement Date Penalty Amount Amount Collected
635218 282372 NOV - Notice of Violation Comply/Closed 2012-05-30
635219 282372 NOV - Notice of Violation Comply/Closed 2012-05-30
635220 282372 NOV - Notice of Violation Comply/Closed 2012-05-30
791129 356111 NOV - Notice of Violation

For data sources see[6]

References