{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.249428,"lon":-76.45625,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Columbia | |
Municipality: Pine Township | |
Operator Name: XTO ENERGY INC | |
Well Pad ID: 146353 | |
Farm/Lease Name: HOUSEWEART 8527H | |
License Status: PLUGGED & ABANDONED | |
Spud Date: | |
Permit Date: 2010-07-23 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: No | |
Latitude: 41.249428 | |
Longitude: -76.456250 |
Date | Event |
---|---|
2010-07-23 | New Permit Application |
2011-05-11 | Performed Spud Operation |
2011-06-25 | Drilling Completion |
2011-07-07 | Perforation |
2012-04-19 | DEVIATED |
2014-04-23 | Drilling Completion |
2015-05-12 | FULLY PLUGGED |
For data sources see[4]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2011-08-08 | 2011-08-08 | 7,998 | 7,182,978 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | Biocide - MC 8650 | Multi-Chem Group | Biocide | Other -(non hazardous) | 40.00 | 0.00285000 | ||
Whole Product | 100.00 | |||||||
Glutaraldehyde | 111-30-8 | 60.00 | 0.00428000 | |||||
Acid - 15 HCl Acid | Pumpco Services | Acid | Hydrochloric acid | 7647-01-0 | 15.00 | 0.00978000 | ||
Other -(non hazardous) | 85.00 | 0.05 | ||||||
Whole Product | 100.00 | |||||||
Scale Inhibitor - MC-MX-588-2 | Multi-Chem Group | Scale Inhibitor | Whole Product | 100.00 | ||||
Other -(non hazardous) | 100.00 | 0.02 | ||||||
Acid - 7.5 HCl Acid | Pumpco Services | Acid | Other -(non hazardous) | 92.50 | 0.42 | |||
Hydrochloric acid | 7647-01-0 | 7.50 | 0.03 | |||||
Whole Product | 100.00 | |||||||
Friction Reducer - MC MX-14-5 | Multi-Chem Group | Friction Reducer | Whole Product | 100.00 | ||||
Other -(non hazardous) | 70.00 | 0.03 | ||||||
Distillates, petroleum, hydrotreated light | 64742-47-8 | 30.00 | 0.01 | |||||
Water | Water | 7732-18-5 | 100.00 | 88.19 | ||||
Sand | Proppant | Quartz | 14808-60-7 | 100.00 | 11.19 | |||
Acid Non Emulsifier PlexBreak-145 | Pumpco Services | Non-Emulsifier | Methanol | 67-56-1 | 15.00 | 0.00007000 | ||
Whole Product | 100.00 | |||||||
Other -(non hazardous) | 85.00 | 0.00042000 | ||||||
Acid Iron Chelating Agt Ferriplex 40 | Pumpco Services | Iron Chelating Agent | Sodium hydroxide | 1310-73-2 | 1.00 | 0.00002000 | ||
Other -(non hazardous) | 57.00 | 0.00098000 | ||||||
Sodium sulfate | 7757-82-6 | 2.00 | 0.00003000 | |||||
Whole Product | 100.00 | |||||||
Nitrilotriacetic acid trisodium monohydrate | 18662-53-8 | 40.00 | 0.00069000 | |||||
Biocide - MC 8520 | Multi-Chem Group | Biocide | 3,4,4-Trimethyloxazolidine | 75673-43-7 | 4.50 | 0.00072000 | ||
4,4-Dimethyloxazolidine | 51200-87-4 | 95.00 | 0.01 | |||||
2-Amino-2-methylpropan-1-ol | 124-68-5 | 0.50 | 0.00008000 | |||||
Whole Product | 100.00 | |||||||
Acid Corrosion Inhibitor Plexhib 256 | Pumpco Services | Corrosion Inhibitor | Propargyl alcohol | 107-19-7 | 8.00 | 0.00004000 | ||
Other -(non hazardous) | 52.00 | 0.00023000 | ||||||
Whole Product | 100.00 | |||||||
Methanol | 67-56-1 | 40.00 | 0.00018000 |
For data sources see[5]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2010 | XTO ENERGY INC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2011 | XTO ENERGY INC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2012 | XTO ENERGY INC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2013 | XTO ENERGY INC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2014 | XTO ENERGY INC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
For data sources see[6]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2011 | XTO ENERGY INC | Fracing Fluid Waste | 549.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0254185 |
2011 | XTO ENERGY INC | Fracing Fluid Waste | 2,541.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR119 |
2011 | XTO ENERGY INC | Fracing Fluid Waste | 120.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014 | XTO ENERGY INC | Produced Fluid | 500.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
2014 | XTO ENERGY INC | Servicing Fluid | 1,242.95 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
For data sources see[7]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
1948965 | Primary Facility | 2011-02-10 | Routine/Partial Inspection | No Violations Noted | |
1957462 | Primary Facility | 2011-03-08 | Routine/Partial Inspection | No Violations Noted | |
1973453 | Primary Facility | 2011-05-16 | Drilling/Alteration | No Violations Noted | |
1974201 | Primary Facility | 2011-05-12 | Follow-up Inspection | Violation(s) Noted | |
1978122 | Primary Facility | 2011-05-31 | Routine/Partial Inspection | No Violations Noted | |
2003840 | Primary Facility | 2011-09-19 | Drilling/Alteration | Violation(s) Noted | |
2003861 | Primary Facility | 2011-09-20 | Follow-up Inspection | Outstanding Violations - No Viols Req'd | |
2065773 | Primary Facility | 2012-05-07 | Routine/Complete Inspection | No Violations Noted | |
2129461 | Primary Facility | 2013-01-07 | Routine/Complete Inspection | Outstanding Violations - No Viols Req'd | |
2150512 | Primary Facility | 2013-03-22 | Routine/Complete Inspection | No Violations Noted | |
2157021 | Primary Facility | 2013-04-10 | Routine/Complete Inspection | Outstanding Violations - No Viols Req'd | |
2264757 | Primary Facility | 2014-04-02 | Plugging(Includes Plugged/Mined Through) | Outstanding Violations - No Viols Req'd | |
2264763 | Primary Facility | 2014-04-01 | Plugging(Includes Plugged/Mined Through) | Outstanding Violations - No Viols Req'd | |
2264795 | Primary Facility | 2014-04-02 | Plugging(Includes Plugged/Mined Through) | Outstanding Violations - No Viols Req'd | |
2265064 | Primary Facility | 2014-04-15 | Plugging(Includes Plugged/Mined Through) | Outstanding Violations - No Viols Req'd | |
2268391 | Primary Facility | 2014-05-05 | Plugging(Includes Plugged/Mined Through) | No Violations Noted |
Inspection ID | Violation ID | Violation Date | Date Resolved | Violation Code | Violation Type | Violation Comments |
---|---|---|---|---|---|---|
1974201 | 611452 | 05/12/2011 | 2011-05-12 | 78.56(1) - Pit and tanks not constructed with sufficient capacity to contain pollutional substances. | Administrative | 78.56(a) Failure to contain pollution substance (drilling mud) |
1974201 | 611453 | 05/12/2011 | 2011-05-12 | CSL402POTPOL - There is a potential for polluting substance(s) reaching Waters of the Commonwealth and may require a permit | Environmental Health & Safety | |
1974201 | 611454 | 05/12/2011 | 2011-05-12 | SWMA301 - Failure to properly store, transport, process or dispose of a residual waste. | Environmental Health & Safety | |
2003840 | 620450 | 09/19/2011 | 2011-09-19 | 78.86* - Failure to report defective, insufficient, or improperly cemented casing w/in 24 hrs or submit plan to correct w/in 30 days | Administrative | The presence of methane in the 13 3/8 x 9 5/8 casing annulus |