Well Details

Well ID: 37-051-24422
Loading map...
Country: United States
State: Pennsylvania
County: Fayette
Municipality: North Union Township
Operator Name: CHEVRON APPALACHIA LLC
Well Pad ID: 148935
Farm/Lease Name: MUTNANSKY UNIT 11H
License Status:
Spud Date:
Permit Date: 2011-01-28
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: Yes
Latitude: 39.945839
Longitude: -79.719947

For data sources see[1][2][3]

Well History

Date Event
2011-01-28 New Permit Application
2011-04-01 Performed Spud Operation
2011-06-04 Drilling Completion
2011-10-21 Drilling Completion
2012-01-26 Perforation
2012-01-26 Performed Stimulation
2016-04-11 DEVIATED
2016-04-11 NEWLY DRILLED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2012-02-02 2012-02-02 7,125 2,956,009

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 EC6486A Nalco Scale Inhibitor Ethylene glycol 107-21-1 30.00 0.00746000
Biocide EC 6116A Nalco Biocide 2,2-Dibromo-3-nitrilopropionamide 10222-01-2 30.00 0.00756000
Dibromoacetonitrile 3252-43-5 5.00 0.00126000
Polyethylene glycol 25322-68-3 60.00 0.01
ASP 900 Nalco Friction Reducer Ammonium sulfate 7783-20-2 30.00
GBW-30 BREAKER Halliburton Energy Services Gel Breaker Carbohydrates 95.00 0.00010000
Hemicellulase enzyme 9012-54-8 15.00 0.00002000
7.5 Hcl Acid Used to open perfs Hydrochloric acid 7647-01-0 7.50 0.27
EC6673W Nalco Iron Control Ethylene glycol 107-21-1 30.00 0.00698000
Proppant (lbs) Proppant 8.95 9.91
FR-66 Friction Reducer Halliburton Energy Services Friction Reducer Distillates, petroleum, hydrotreated light 64742-47-8 30.00 0.03
WG-36 GELLING AGENT Halliburton Energy Services Water Viscosifier Guar gum 9000-30-0 100.00 0.00301000
Clean Volume (gals) Carrier/Base Fluid 91.05 100.00

For data sources see[5]

Stimulation Data

Stimulation Date Phase Number Chemical Agent Volume (gal) Treating Pressure (psi) Breakdown Pressure (psi)
2012-01-26 0 0 0

For data sources see[6]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2010 ATLAS RESOURCES LLC 0.00 0 0.00 0 0.00 0
2011 ATLAS RESOURCES LLC 0.00 0 0.00 0 0.00 0
2012 CHEVRON APPALACHIA LLC 350,820.00 214 0.00 0 0.00 0
2013 CHEVRON APPALACHIA LLC 343,754.00 365 0.00 0 0.00 0
2014 CHEVRON APPALACHIA LLC 220,750.00 334 0.00 0 0.00 0
2015 CHEVRON APPALACHIA LLC 163,453.00 365 0.00 0 0.00 0
2016 CHEVRON APPALACHIA LLC 112,540.00 366 0.00 0 0.00 0
2017 CHEVRON APPALACHIA LLC 102,810.00 179 0.00 0 0.00 0
2018 CHEVRON APPALACHIA LLC 116,485.00 365 0.00 0 0.00 0
2019 CHEVRON APPALACHIA LLC 107,507.00 365 0.00 0 0.00 0

For data sources see[7]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2011 CHEVRON APPALACHIA LLC Drilling Fluid Waste 3,980.00 Bbl REUSE OTHER THAN ROAD SPREADING
2011 CHEVRON APPALACHIA LLC Drilling Fluid Waste 1,957.50 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW001
2011 CHEVRON APPALACHIA LLC Fracing Fluid Waste 1,670.00 Bbl REUSE OTHER THAN ROAD SPREADING
2012 CHEVRON APPALACHIA LLC Produced Fluid 2,061.00 Bbl REUSE OTHER THAN ROAD SPREADING
2012 CHEVRON APPALACHIA LLC Drill Cuttings 0.07 Tons LANDFILL 100419
2012 CHEVRON APPALACHIA LLC Fracing Fluid Waste 3,080.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW001
2012 CHEVRON APPALACHIA LLC Fracing Fluid Waste 16,266.95 Bbl REUSE OTHER THAN ROAD SPREADING
2013 CHEVRON APPALACHIA LLC Produced Fluid 1,170.00 Bbl REUSE OTHER THAN ROAD SPREADING
2014 CHEVRON APPALACHIA LLC Produced Fluid 16.25 Bbl INJECTION DISPOSAL WELL 34-121-23995
2014 CHEVRON APPALACHIA LLC Produced Fluid 740.25 Bbl REUSE OTHER THAN ROAD SPREADING
2015 CHEVRON APPALACHIA LLC Produced Fluid 428.75 Bbl REUSE OTHER THAN ROAD SPREADING
2016 CHEVRON APPALACHIA LLC Produced Fluid 55.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW019
2016 CHEVRON APPALACHIA LLC Produced Fluid 176.25 Bbl REUSE OTHER THAN ROAD SPREADING
2017 CHEVRON APPALACHIA LLC Produced Fluid 55.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW001
2017 CHEVRON APPALACHIA LLC Produced Fluid 26.25 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2017 CHEVRON APPALACHIA LLC Produced Fluid 120.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2017 CHEVRON APPALACHIA LLC Produced Fluid 62.50 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2017 CHEVRON APPALACHIA LLC Produced Fluid 106.75 Bbl REUSE (AT WELL PAD)
2017 CHEVRON APPALACHIA LLC Synthetic Liner Materials 1.01 Tons LANDFILL 100663
2018 CHEVRON APPALACHIA LLC Produced Fluid 166.25 Bbl REUSE (AT WELL PAD)
2018 CHEVRON APPALACHIA LLC Produced Fluid 49.25 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2019 CHEVRON APPALACHIA LLC Produced Fluid 356.97 Bbl REUSE (AT WELL PAD)

For data sources see[8]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1961157 Primary Facility 2011-03-28 Routine/Complete Inspection No Violations Noted
1970547 Primary Facility 2011-05-03 Routine/Complete Inspection No Violations Noted
1973589 Primary Facility 2011-05-17 Routine/Complete Inspection No Violations Noted
1979126 Primary Facility 2011-06-08 Routine/Complete Inspection No Violations Noted
1984096 Primary Facility 2011-06-03 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS, E&S AND PITS IN GOOD CONDITION. RUNNING 8 5/8" PIPE TODAY,CEMENTING TONIGHT. MOVING TO MUTNANSKY 12-H (6/4/2011).
1984131 Primary Facility 2011-05-30 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS,E&S AND PITS IN GOOD CONDITION. SETTING COAL STRING @ 401' AND CEMENTING TONIGHT.
1984134 Primary Facility 2011-05-27 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS, E&S AND PITS IN GOOD CONDITION. SETTING SURFACE CASING @ 249' TODAY AND CEMENTING TONIGHT.
1984138 Primary Facility 2011-04-01 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS, E&S AND PITS IN GOOD CONDITION. SETTING CONDUCTOR @ 30'.
1991492 Primary Facility 2011-07-28 Routine/Complete Inspection No Violations Noted
1995658 Primary Facility 2011-08-15 Routine/Complete Inspection No Violations Noted
2005029 Primary Facility 2011-08-19 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS, E&S & PITS IN GOOD CONDITION. CROWN # 5 MOVING ONTO MUTNANSKY 11 - H TODAY.
2005036 Primary Facility 2011-08-24 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS, E&S & PITS IN GOOD CONDITION. CROWN # 5 TD @ 7107' .MUDDING UP AND CAPPED (8/24/2011).
2015130 Primary Facility 2011-10-14 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS, PATTERSON - 325 DRILLING ON (MUTNANSKY 11- H )ON FLUID @ 8096' .
2017346 Primary Facility 2011-10-06 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS, PATTERSON -324 RIGGING UP ON MUTNANSKY 11 - H.
2017349 Primary Facility 2011-10-28 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS, PATTERSON - 324 DRILLING ON FLUID @ 10,973' TODAY ,EXSPECTING TO (TD) TONIGHT @ 11, 973' , PLANNING TO RUN PROD. CASING LATE TONIGHT AND CEMENTING SAT. MORNING.
2144423 Primary Facility 2013-03-01 Routine/Complete Inspection No Violations Noted Site ID sign in place, E&S, PPC, permits in box. Site mostly restored, wells labeled, tanks in containment. Some silt fence in field remaining from previous sed trap removal. No leaks observed today.
2223547 Primary Facility 2013-11-20 Routine/Complete Inspection No Violations Noted On 11/20/2013, the Department performed an Notice of Termination inspection at the site of Chevron Appalachia’s Mutnansky Unit 9, 10, 11, 12H well site in North Union Twp., Fayette County. The ESX10-051-0011 is the site permit being inspected for the N.O.T.
2373086 Primary Facility 2015-05-15 Routine/Complete Inspection No Violations Noted
2421518 Primary Facility 2015-10-14 Routine/Complete Inspection No Violations Noted
2483687 Primary Facility 2016-04-26 Routine/Complete Inspection No Violations Noted

On 10/14/15 I conducted a complaint inspection of the Mutnansky Unit in response to a complaint alleging that erosion had occurred at the site. At the time of inspection significant accelerated erosion was present. It was highly recommended that the issues present be addressed. I met with Mike Herman of Chevron at the site and he indicated that Chevron would be moving forward to address the issues at the site.

On 04/26/16 at approximately 1330 hours I conducted a routine complete inspection of the Mutnansky Unit. The Act 9 sign was in place and all required documents were present at the site. The accelerated erosion noted on 10/14/15 had not been repaired. It appears that a location part way up the pad slope was saturated and was the origin of the accelerated erosion. It is highly recommended that this be investigated.

2560511 Primary Facility 2017-01-27 Routine/Complete Inspection No Violations Noted On 01/27/17 at approximately 1300 hours I conducted a follow up inspection of the Mutnansky Unit. An NOV had been issued on 04/26/16 for 102.22(a). On the date of inspection the Act 9 sign was in place and all required documents were on site.
The majority of the site was well vegetated. The erosion noted in the NOV had been repaired, but erosion channels and what appeared to be tire tracks were present in the location of the repairs. BMPs were in place and sediment was not observed leaving the site. It is recommended that these issues be addressed once weather conditions permit.
2624004 Primary Facility 2017-08-07 Compliance Evaluation No Violations Noted The Act 9 sign was in place and all required documents were present at the site. Previously, water was seeping out of the pad slope causing erosion in the natural swale. The erosion was repaired, but earthmoving equipment tracks and ruts were still visible. The ruts were repaired and the area was seeded and mulched. The site overall was well vegetated with the exception of this area. The production equipment appeared to be in good condition. There were no violations observed at the time of inspection.
2825596 Primary Facility 2019-01-11 Routine/Complete Inspection No Violations Noted This well is tagged and in production. The well head casing, piping, production set equipment, containment dike and tank battery look ok.