X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-051-24522

Well Details

Well ID: 37-051-24522
Loading map...
Country: United States
State: Pennsylvania
County: Fayette
Municipality: Franklin Township
Operator Name: CHEVRON APPALACHIA LLC
Well Pad ID: 146724
Farm/Lease Name: ROSA UNIT 9H
License Status:
Spud Date:
Permit Date: 2012-10-10
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 40.035386
Longitude: -79.773394

For data sources see[1][2][3]

Well History

Date Event
2012-10-10 New Permit Application
2012-10-26 Performed Spud Operation
2013-05-26 Drilling Completion
2013-09-26 Perforation
2013-09-26 Performed Stimulation
2016-04-25 DEVIATED

For data sources see[4]

Stimulation Data

Stimulation Date Phase Number Chemical Agent Volume (gal) Treating Pressure (psi) Breakdown Pressure (psi)
2013-09-26 0 0 0

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2012 CHEVRON APPALACHIA LLC 0.00 0 0.00 0 0.00 0
2013 CHEVRON APPALACHIA LLC 0.00 0 0.00 0 0.00 0
2014 CHEVRON APPALACHIA LLC 586,430.00 188 0.00 0 45.83 184
2015 CHEVRON APPALACHIA LLC 602,464.00 365 0.00 0 0.00 0
2016 CHEVRON APPALACHIA LLC 414,736.00 366 0.00 0 0.00 0
2017 CHEVRON APPALACHIA LLC 317,960.00 365 0.00 0 0.00 0
2018 CHEVRON APPALACHIA LLC 262,092.00 365 0.00 0 0.00 0
2019 CHEVRON APPALACHIA LLC 217,624.00 365 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2012 CHEVRON APPALACHIA LLC Drill Cuttings 50.17 Tons LANDFILL 100419
2013 CHEVRON APPALACHIA LLC Fracing Fluid Waste 777.70 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW001
2013 CHEVRON APPALACHIA LLC Fracing Fluid Waste 1,773.00 Bbl REUSE OTHER THAN ROAD SPREADING
2013 CHEVRON APPALACHIA LLC Drilling Fluid Waste 187.30 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW001
2013 CHEVRON APPALACHIA LLC Drill Cuttings 644.38 Tons LANDFILL 100419
2013 CHEVRON APPALACHIA LLC Drilling Fluid Waste 2,294.20 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW001
2014 CHEVRON APPALACHIA LLC Fracing Fluid Waste 1,737.83 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW001
2014 CHEVRON APPALACHIA LLC Fracturing Fluid Waste 4.46 Tons LANDFILL 100592
2014 CHEVRON APPALACHIA LLC Produced Fluid 45.83 Bbl INJECTION DISPOSAL WELL 34-121-23995
2014 CHEVRON APPALACHIA LLC Fracturing Fluid Waste 28.84 Tons STORAGE PENDING DISPOSAL OR REUSE MID0209062814
2014 CHEVRON APPALACHIA LLC Fracturing Fluid Waste 3.95 Tons LANDFILL 100172
2014 CHEVRON APPALACHIA LLC Fracing Fluid Waste 14,445.00 Bbl REUSE OTHER THAN ROAD SPREADING
2014 CHEVRON APPALACHIA LLC Produced Fluid 2,087.50 Bbl REUSE OTHER THAN ROAD SPREADING
2014 CHEVRON APPALACHIA LLC Fracturing Fluid Waste 2.91 Tons LANDFILL 76-00-08
2015 CHEVRON APPALACHIA LLC Fracturing Fluid Waste 1.76 Tons LANDFILL 073 114 654
2015 CHEVRON APPALACHIA LLC Produced Fluid 1,521.67 Bbl REUSE OTHER THAN ROAD SPREADING
2016 CHEVRON APPALACHIA LLC Produced Fluid 494.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016 CHEVRON APPALACHIA LLC Produced Fluid 336.18 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW019
2017 CHEVRON APPALACHIA LLC Produced Fluid 1,558.33 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW001
2017 CHEVRON APPALACHIA LLC Produced Fluid 75.17 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2017 CHEVRON APPALACHIA LLC Produced Fluid 130.84 Bbl REUSE (AT WELL PAD)
2017 CHEVRON APPALACHIA LLC Produced Fluid 229.26 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2017 CHEVRON APPALACHIA LLC Produced Fluid 19.17 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2018 CHEVRON APPALACHIA LLC Produced Fluid 164.66 Bbl REUSE (AT WELL PAD)
2018 CHEVRON APPALACHIA LLC Produced Fluid 17.17 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2018 CHEVRON APPALACHIA LLC Produced Fluid 177.33 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018 CHEVRON APPALACHIA LLC Produced Fluid 18.33 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2019 CHEVRON APPALACHIA LLC Produced Fluid 21.67 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2019 CHEVRON APPALACHIA LLC Produced Fluid 338.33 Bbl REUSE (AT WELL PAD)
2019 CHEVRON APPALACHIA LLC Produced Fluid 20.00 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2113104 Primary Facility 2012-10-31 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS, ROCKY MOUTAIN # 1 DRILLING 24" CONDUCTOR CASING @ 70' (10/27/2012).
2121758 Primary Facility 2012-06-13 Routine/Complete Inspection No Violations Noted Pre-op Inspection of well site. Perimeter E&S in place and functioning.
2151017 Primary Facility 2013-02-28 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS, CROWN # 5 DRILLING ON AIR @ 2136' (TD).RUNNING INTERMEDITE CASING AND CEMENTING TODAY(2/28/2013).
2151019 Primary Facility 2013-02-25 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS, CROWN # 5 DRILLING ON AIR @ 250' (TD). RUNNING COAL PROTECTION CASING AND CEMENTING TODAY (2/23/2013).
2151021 Primary Facility 2013-02-21 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS, CROWN # 5 DRILLING ON AIR @ 150' (TD). RUNNING WATER PROTECTION CASING AND CEMENTING TODAY.
2169941 Primary Facility 2013-05-21 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS, PATTERSON # 334 DRILLING ON FLUID @ 5160' TODAY. ALL LOOKS GOOD ON SITE.
2169946 Primary Facility 2013-05-16 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS, PATTERSON # 334 MOVING ON TO ROSA # 9 -H TODAY.
2178632 Primary Facility 2013-05-28 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS, PATTERSON # 334 DRILLING ON FLUID @ 12,540' (TD). RUNNING 51/2" PROD. CASING AND CEMENTING TONIGHT (5/26/2013).
2207827 Primary Facility 2013-09-27 Administrative/File Review In Compliance with Policy Spill. 1 barrel re-use water on secondary containment. Occurred on 9/27/2013. Material vacuumed up and re-used in the frac. No impact to streams or land.
2237155 Primary Facility 2014-01-15 Routine/Complete Inspection No Violations Noted On 1/15/2014, the Department conducted an inspection of the Chevron Appalachia Rosa 6H to 11H well site in Franklinn Twp., Fayette County.
2252554 Primary Facility 2014-03-11 Routine/Complete Inspection No Violations Noted On 3/11/2014, the Department conducted an inspection at the Chevron Appalachia's Rosa 6H - 11H well site in Franklin Twp., Fayette County. The reason for the inspection was a request by the operator for an extension on the date that the site needed to be restored by. The original restoration date was 3/20/2014 and an extension to 3/20/16 is being requested.
2374021 Primary Facility 2015-05-28 Routine/Complete Inspection No Violations Noted
2487017 Primary Facility 2016-05-05 Routine/Complete Inspection No Violations Noted On 05/05/16 at approximately 0730 hours I conducted a routine complete inspection of the Rosa Unit. The Act 9 sign was in place and visible. All required documents were present in the mail box. The site overall was well vegetated. There were no violations observed at the time of inspection.
2487043 Primary Facility 2016-05-13 Routine/Complete Inspection No Violations Noted

On 05/05/16 at approximately 1300 hours I conducted a routine complete inspection of the Rosa Unit. The Act 9 sign was in place and visible. All required documents were present in the mail box. The site overall was well vegetated. The purpose of the site visit was to meet with Mr. Blaney, landowner of part of the area permitted, and Nick Staffieri of Chevron to discuss Mr. Blaney farming a portion of the area under permit to the north east and east of the pad. The area has traditionally been farmed and there were no waters of the Commonwealth present in the immediate area or downslope of the area to be farmed observed. Approval was granted to Mr. Blaney to begin farming his land.

2566326 Primary Facility 2017-03-01 Routine/Complete Inspection No Violations Noted The Act 9 sign was in place and all required documents were present. The site was well vegetated and there were no signs of erosion observed. Despite heavy rains, stormwater controls appeared to be properly functioning. The on pad equipment appeared to be in good condition. There were no violations observed at the time of inspection.
2584846 Primary Facility 2017-04-20 Routine/Complete Inspection No Violations Noted The Act 9 sign was in place and all required documents were present at the site. The site was well vegetated and there were no signs of erosion observed. BMPs appeared to be well-maintained. The production equipment appeared to be in good condition. There were no violations observed at the time of inspection.
2603169 Primary Facility 2017-06-12 Routine/Complete Inspection No Violations Noted The Act 9 sign was in place, but the E&S plans reflecting the major mod were not present on site. I contacted Chevron and a set of plans will be placed on the site. The site was well vegetated except the recently disturbed locations. PCSM had recently been added to the site and the disturbed areas appeared to have been seeded and mulched. There were no signs of erosion observed at the time of inspection.
2615364 Primary Facility 2017-06-30 Routine/Complete Inspection No Violations Noted Representatives of Chevron requested an on site meeting at the location to discuss the installation of a drainage channel. Since the site was constructed, a landowner constructed a home and graded the land adjacent to the access road to the south east. Chevron recently installed a drainage channel and rain garden on the opposite side of the access road and were to begin construction of the channel of interest when the landowner voiced their concerns that they did not want the channel installed.

The location where the channel is to be installed is well vegetated and there were no signs of erosion observed. Chevron is seeking guidance if the channel could not be installed and the plan amended by red line changes or if a major or minor modification would need to be submitted to DEP Environmental Engineering staff. This WQS is requesting guidance from Department Environmental Engineering staff regarding the issue. Once a determination has been made Chevron will be notified.

2682061 Primary Facility 2018-01-10 Routine/Complete Inspection No Violations Noted The Act 9 sign was in place and all required documents were present at the site. The site was well vegetated and there were no signs of erosion observed. The production equipment appeared to be in good condition. There were no violations observed at the time of inspection.
2734116 Primary Facility 2018-05-24 Routine/Complete Inspection No Violations Noted The Act 9 sign was in place and all required documents were present at the site. The site was well vegetated. The production equipment appeared to be in good condition. There were no violations observed at the time of inspection.
2771486 Primary Facility 2018-08-27 Routine/Complete Inspection No Violations Noted The Act 9 sign was in place and all required documents were present at the site. The site was well vegetated and there were no signs of erosion were observed. The access road showed signs of washout. It is recommended the road receive maintenance.

Installed PCSM features appeared to be in good condition. The roadside ditch along the right side of the access road adjacent to a property owner's yard was still not installed. The property owner requested the ditch not be installed to allow them to mow their yard more easily. Chevron is currently preparing a modification to submit to the Department to address the issue.

The production equipment appeared to be in good condition. There were no violations observed at the time of inspection.

For data sources see[8]

References