If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-053-27052 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.60709,"lon":-79.063883,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Forest | |
Municipality: Howe Township | |
Operator Name: CAMERON ENERGY CO | |
Well Pad ID: | |
Farm/Lease Name: FOX WARRANT TRACT 298 I 21B6 | |
License Status: ACTIVE | |
Spud Date: | |
Permit Date: 1998-08-10 | |
Well Type: OIL | |
Unconventional Well: N | |
Configuration: Vertical Well | |
Conservation: No | |
Latitude: 41.607090 | |
Longitude: -79.063883 |
Date | Event |
---|---|
1998-08-10 | New Permit Application |
1999-04-01 | Performed Spud Operation |
1999-04-05 | Drilling Completion |
1999-04-30 | Perforation |
2000-04-13 | NEWLY DRILLED |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
1999 | AZCO OPR CO | 640.67 | 365 | 155.56 | 365 | 0.00 | 0 |
2000 | AZCO OPR CO | 519.64 | 365 | 173.22 | 365 | 0.00 | 0 |
2001 | AZCO OPR CO | 467.78 | 365 | 155.92 | 365 | 0.00 | 0 |
2010 | DUHRING RESOURCE CO | 712.84 | 365 | 161.96 | 365 | 0.00 | 0 |
2011 | DUHRING RESOURCE CO | 886.24 | 365 | 157.79 | 365 | 0.00 | 0 |
2012 | DUHRING RESOURCE CO | 1.92 | 365 | 11.81 | 365 | 0.08 | 365 |
2013 | CAMERON ENERGY CO | 83.33 | 365 | 4.17 | 365 | 0 | 365 |
2014 | CAMERON ENERGY CO | 25.00 | 365 | 4.17 | 365 | 0 | 365 |
2015 | CAMERON ENERGY CO | 25.00 | 365 | 0.00 | 0 | 0 | 365 |
2016 | CAMERON ENERGY CO | 25.00 | 365 | 0.00 | 0 | 0 | 365 |
2017 | CAMERON ENERGY CO | 25.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2018 | CAMERON ENERGY CO | 25.00 | 365 | 0.00 | 0 | 0.00 | 0 |
For data sources see[5]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2010 | DUHRING RESOURCE CO | Produced Fluid | 25.09 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0102784 |
2011 | DUHRING RESOURCE CO | Produced Fluid | 44.49 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0102784 |
2012 | DUHRING RESOURCE CO | Produced Fluid | 0.77 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0102784 |
2013 | CAMERON ENERGY CO | Produced Fluid | 1.67 Bbl | CENT WASTE TRT FAC NPDES | PA0102784 |
2013 | CAMERON ENERGY CO | Produced Fluid | 1.67 Bbl | CENT WASTE TRT FAC NPDES DISCHARGE | PA0102784 |
2014 | CAMERON ENERGY CO | Produced Fluid | 0.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2015 | CAMERON ENERGY CO | Produced Fluid | 0.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016 | CAMERON ENERGY CO | Produced Fluid | 0.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2017 | CAMERON ENERGY CO | Produced Fluid | 0.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2018 | CAMERON ENERGY CO | Produced Fluid | 0.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2019 | CAMERON ENERGY CO | Produced Fluid | 0.17 Bbl | REUSE AT A CONVENTIONAL WELL SITE IN PA |
For data sources see[6]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
1045886 | Primary Facility | 2001-07-10 | Follow-up Inspection | No Violations Noted | |
1486844 | Primary Facility | 2005-10-11 | Routine/Complete Inspection | No Violations Noted | |
387314 | Primary Facility | 1999-05-24 | Routine/Complete Inspection | Violation(s) Noted | |
387447 | Primary Facility | 1999-07-13 | Routine/Complete Inspection | Violation(s) Noted | |
387653 | Primary Facility | 1999-08-23 | Routine/Complete Inspection | Violation(s) Noted | |
894183 | Primary Facility | 1999-10-28 | Routine/Complete Inspection | Violation(s) Noted | Did not imput violation for lack of NPDES permit. |
915522 | Primary Facility | 2000-02-03 | Compliance Evaluation | Outstanding Violations - Viols Req'd | |
915617 | Primary Facility | 2000-02-09 | Compliance Evaluation | Outstanding Violations - Viols Req'd | |
917968 | Primary Facility | 2000-02-17 | Compliance Evaluation | Outstanding Violations - Viols Req'd | |
931749 | Primary Facility | 2000-04-12 | Routine/Complete Inspection | No Violations Noted | |
932632 | Primary Facility | 2000-04-12 | Compliance Evaluation | Violation(s) Noted | |
932633 | Primary Facility | 2000-04-12 | Compliance Evaluation | Violation(s) Noted | |
952029 | Primary Facility | 2000-07-18 | Compliance Evaluation | Outstanding Violations - Viols Req'd | |
955492 | Primary Facility | 2000-07-27 | Compliance Evaluation | Outstanding Violations - Viols Req'd | |
955549 | Primary Facility | 2000-07-26 | Compliance Evaluation | Outstanding Violations - Viols Req'd | |
964336 | Primary Facility | 2000-08-30 | Compliance Evaluation | Outstanding Violations - Viols Req'd | |
967259 | Primary Facility | 2000-09-12 | Compliance Evaluation | Outstanding Violations - Viols Req'd | |
967281 | Primary Facility | 2000-09-06 | Compliance Evaluation | Outstanding Violations - Viols Req'd |
Inspection ID | Violation ID | Violation Date | Date Resolved | Violation Code | Violation Type | Violation Comments |
---|---|---|---|---|---|---|
387314 | 113919 | 05/24/1999 | 1999-05-24 | 102.4 - Failure to minimize accelerated erosion, implement E&S plan, maintain E&S controls. Failure to stabilize site until total site restoration under OGA Sec 206(c)(d) | Environmental Health & Safety | |
387314 | 113920 | 05/24/1999 | 1999-05-24 | 102.4NOPLAN - No E&S plan developed, plan not on site | Administrative | |
387447 | 114005 | 07/13/1999 | 1999-07-13 | 102.4NOPLAN - No E&S plan developed, plan not on site | Administrative | |
387447 | 114006 | 07/13/1999 | 1999-07-13 | 102.4 - Failure to minimize accelerated erosion, implement E&S plan, maintain E&S controls. Failure to stabilize site until total site restoration under OGA Sec 206(c)(d) | Environmental Health & Safety | |
387653 | 114149 | 08/23/1999 | 1999-08-23 | 102.4NOPLAN - No E&S plan developed, plan not on site | Administrative | |
387653 | 114150 | 08/23/1999 | 1999-08-23 | 102.4 - Failure to minimize accelerated erosion, implement E&S plan, maintain E&S controls. Failure to stabilize site until total site restoration under OGA Sec 206(c)(d) | Environmental Health & Safety | |
894183 | 227018 | 10/28/1999 | 1999-10-28 | 102.4INADPLN - E&S Plan not adequate | Administrative | Inspected with Ken Scott and Joe Kelly as part of review of NPDES application. |
915522 | 232498 | 02/03/2000 | 2000-02-03 | 102.4 - Failure to minimize accelerated erosion, implement E&S plan, maintain E&S controls. Failure to stabilize site until total site restoration under OGA Sec 206(c)(d) | Environmental Health & Safety | Documented controls installed. |
915617 | 232518 | 02/09/2000 | 2000-02-09 | 102.4 - Failure to minimize accelerated erosion, implement E&S plan, maintain E&S controls. Failure to stabilize site until total site restoration under OGA Sec 206(c)(d) | Environmental Health & Safety | Documented controls installed |
917968 | 233115 | 02/17/2000 | 2000-02-17 | 102.4 - Failure to minimize accelerated erosion, implement E&S plan, maintain E&S controls. Failure to stabilize site until total site restoration under OGA Sec 206(c)(d) | Environmental Health & Safety | no rock hauled yet. |
932632 | 237371 | 04/12/2000 | 2000-04-12 | 102.4 - Failure to minimize accelerated erosion, implement E&S plan, maintain E&S controls. Failure to stabilize site until total site restoration under OGA Sec 206(c)(d) | Environmental Health & Safety | no change |
932633 | 237372 | 04/12/2000 | 2000-04-12 | 102.4 - Failure to minimize accelerated erosion, implement E&S plan, maintain E&S controls. Failure to stabilize site until total site restoration under OGA Sec 206(c)(d) | Environmental Health & Safety | no change |
952029 | 242174 | 07/18/2000 | 2000-07-18 | 102.4 - Failure to minimize accelerated erosion, implement E&S plan, maintain E&S controls. Failure to stabilize site until total site restoration under OGA Sec 206(c)(d) | Environmental Health & Safety | No change since last inspection. |
955492 | 242957 | 07/27/2000 | 2000-07-27 | 102.4 - Failure to minimize accelerated erosion, implement E&S plan, maintain E&S controls. Failure to stabilize site until total site restoration under OGA Sec 206(c)(d) | Environmental Health & Safety | no change |
955549 | 242994 | 07/26/2000 | 2000-07-26 | 102.4 - Failure to minimize accelerated erosion, implement E&S plan, maintain E&S controls. Failure to stabilize site until total site restoration under OGA Sec 206(c)(d) | Environmental Health & Safety | no change |
964336 | 246651 | 08/30/2000 | 2000-08-30 | 102.4 - Failure to minimize accelerated erosion, implement E&S plan, maintain E&S controls. Failure to stabilize site until total site restoration under OGA Sec 206(c)(d) | Environmental Health & Safety | Ray agreed to 1)deepen rock lined ditch 2)establish ditch on left side and deepen turnout |
967259 | 247574 | 09/12/2000 | 2000-09-12 | 102.4 - Failure to minimize accelerated erosion, implement E&S plan, maintain E&S controls. Failure to stabilize site until total site restoration under OGA Sec 206(c)(d) | Environmental Health & Safety | Ditch at entrance still needs fixed. |
967281 | 247584 | 09/06/2000 | 2000-09-06 | 102.4 - Failure to minimize accelerated erosion, implement E&S plan, maintain E&S controls. Failure to stabilize site until total site restoration under OGA Sec 206(c)(d) | Environmental Health & Safety | Ditch at entrance still needs stoned. |
Violation ID | Penalty ID | Penalty Code | Penalty Status | Penalty Date | Enforcement Date | Penalty Amount | Amount Collected |
---|---|---|---|---|---|---|---|
113919 | 4455 | ADORD - Administrative Order | Comply/Closed | 2000-10-31 | |||
113920 | 4455 | ADORD - Administrative Order | Comply/Closed | 2000-10-31 | |||
114005 | 4455 | ADORD - Administrative Order | Comply/Closed | 2000-10-31 | |||
114006 | 4455 | ADORD - Administrative Order | Comply/Closed | 2000-10-31 | |||
114149 | 4455 | ADORD - Administrative Order | Comply/Closed | 2000-10-31 | |||
114150 | 4455 | ADORD - Administrative Order | Comply/Closed | 2000-10-31 | |||
227018 | 4455 | ADORD - Administrative Order | Comply/Closed | 2000-10-31 | |||
232498 | 4455 | ADORD - Administrative Order | Comply/Closed | 2000-10-31 | |||
232518 | 4455 | ADORD - Administrative Order | Comply/Closed | 2000-10-31 | |||
233115 | 4455 | ADORD - Administrative Order | Comply/Closed | 2000-10-31 | |||
237371 | 4455 | ADORD - Administrative Order | Comply/Closed | 2000-10-31 | |||
237372 | 4455 | ADORD - Administrative Order | Comply/Closed | 2000-10-31 | |||
242174 | 4455 | ADORD - Administrative Order | Comply/Closed | 2000-10-31 | |||
242957 | 4455 | ADORD - Administrative Order | Comply/Closed | 2000-10-31 | |||
242994 | 4455 | ADORD - Administrative Order | Comply/Closed | 2000-10-31 | |||
246651 | 4455 | ADORD - Administrative Order | Comply/Closed | 2000-10-31 | |||
247574 | 4455 | ADORD - Administrative Order | Comply/Closed | 2000-10-31 | |||
247584 | 4455 | ADORD - Administrative Order | Comply/Closed | 2000-10-31 |