If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-059-26337 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":39.7949,"lon":-80.054444,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Greene | |
Municipality: Dunkard Township | |
Operator Name: CHEVRON APPALACHIA LLC | |
Well Pad ID: 150623 | |
Farm/Lease Name: PBG-SMITH UNIT 2H | |
License Status: | |
Spud Date: | |
Permit Date: 2013-12-17 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: No | |
Latitude: 39.7949 | |
Longitude: -80.054444 |
Date | Event |
---|---|
2013-12-17 | New Permit Application |
2014-08-10 | Performed Spud Operation |
For data sources see[4]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2016-03-08 | 2016-04-12 | 0 | 7,697,120 | 0 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | Proppant Transport | Schlumberger | Corrosion Inhibitor, Scale Inhibitor, Acid, Breaker, Gelling Agent, Friction Reducer, Iron Control Agent, Myacide|TS GA 25, Accelerator, Chelating Age | Glutaraldehyde | 111-30-8 | 0.11915 | 0.01444 | 0 |
Water (Including Mix Water Supplied by Client)* | NA | 0 | 87.8799 | 0 | ||||
Sodium hydroxide | 1310-73-2 | 0.00197 | 0.00024 | 0 | ||||
Urea | 57-13-6 | 0.01046 | 0.00127 | 0 | ||||
Sodium Glycolate (impurity) | 2836-32-0 | 0.0059 | 0.00071 | 0 | ||||
Dimethyl siloxanes and silicones | 63148-62-9 | 0.00015 | 0.00002000 | 0 | ||||
Non-crystalline silica (impurity) | 7631-86-9 | 0.0024 | 0.00029 | 0 | ||||
Quartz, Crystalline silica | 14808-60-7 | 98.6325 | 11.9544 | 0 | ||||
Trisodium Ethylenediaminetetraacetate (impurity) | 150-38-9 | 0.00197 | 0.00024 | 0 | ||||
Hydrochloric acid | 7647-01-0 | 0.61483 | 0.07452 | 0 | ||||
Decamethyl cyclopentasiloxane | 541-02-6 | 0.00001000 | 0 | 0 | ||||
Polymer of 2-acrylamido-2-methylpropanesulfonic acid sodium salt and methyl acrylate |
136793-29-8 | 0.01703 | 0.00206 | 0 | ||||
Sodium sulfate | 7757-82-6 | 0.00244 | 0.0003 | 0 | ||||
Siloxanes and silicones, dimethyl, reaction products with silica |
67762-90-7 | 0.00002000 | 0 | 0 | ||||
Hemicellulase enzyme | 9012-54-8 | 0.00205 | 0.00025 | 0 | ||||
Acrylamide, 2-acrylamido-2-methylpropanesulfonic acid, sodium salt polymer |
38193-60-1 | 0.15896 | 0.01927 | 0 | ||||
Ammonium sulfate | 7783-20-2 | 0.21537 | 0.0261 | 0 | ||||
Alcohol, C9-C11, Ethoxylated | 68439-46-3 | 0.00054 | 0.00007000 | 0 | ||||
Sodium erythorbate | 6381-77-7 | 0.00474 | 0.00057 | 0 | ||||
Amines, tallow alkyl, ethoxylated | 61791-26-2 | 0.00011 | 0.00001000 | 0 | ||||
Copper(II) sulfate | 7758-98-7 | 0.00001000 | 0 | 0 | ||||
Guar gum | 9000-30-0 | 0.09152 | 0.01109 | 0 | ||||
Calcium Chloride | 10043-52-4 | 0.00322 | 0.00039 | 0 | ||||
Acetic acid(impurity) | 64-19-7 | 0.00014 | 0.00002000 | 0 | ||||
2-Propenamid (impurity) | 79-06-1 | 0.00052 | 0.00006000 | 0 | ||||
Octamethylcyclotetrasiloxane | 556-67-2 | 0.00002000 | 0 | 0 | ||||
Ethylene Glycol | 107-21-1 | 0.00246 | 0.0003 | 0 | ||||
Reaction product of: acetophenone, formaldehyde, cyclohexylamine, methanol and acetic acid |
224635-63-6 | 0.00131 | 0.00016 | 0 | ||||
Alcohols, C10-16, ethoxylated | 68002-97-1 | 0.00036 | 0.00004000 | 0 | ||||
Disodium Ethylene Diamine Tetra Acetate (impurity) | 139-33-3 | 0.00197 | 0.00024 | 0 | ||||
Potassium chloride (impurity) | 7447-40-7 | 0.00009000 | 0.00001000 | 0 | ||||
Acetophenone | 98-86-2 | 0.00014 | 0.00002000 | 0 | ||||
Methanol | 67-56-1 | 0.00316 | 0.00038 | 0 | ||||
Formaldehyde (impurity) | 50-00-0 | 0.00009000 | 0.00001000 | 0 | ||||
Cinnamaldehyde | 104-55-2 | 0.00072 | 0.00009000 | 0 | ||||
Dodecamethylcyclohexasiloxane | 540-97-6 | 0.00001000 | 0 | 0 | ||||
Trisodium ortho phosphate | 7601-54-9 | 0.00863 | 0.00105 | 0 | ||||
Ethanol, 2,2',2-nitrilotris-, 1,1',1-tris(dihydrogen phosphate), sodium salt |
68171-29-9 | 0.01964 | 0.00238 | 0 | ||||
Tetrasodium ethylenediaminetetraacetate | 64-02-8 | 0.07301 | 0.00885 | 0 | ||||
Trisodium nitrilotriacetate (impurity) | 5064-31-3 | 0.00098 | 0.00012 | 0 | ||||
Sodium chloride (impurity) | 7647-14-5 | 0.00005000 | 0.00001000 | 0 |
For data sources see[5]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2014 | CHEVRON APPALACHIA LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2015 | CHEVRON APPALACHIA LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2016 | CHEVRON APPALACHIA LLC | 333,157.00 | 94 | 0.00 | 0 | 0.00 | 0 |
2017 | CHEVRON APPALACHIA LLC | 1,134,389.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2018 | CHEVRON APPALACHIA LLC | 683,864.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2019 | CHEVRON APPALACHIA LLC | 500,260.00 | 365 | 0.00 | 0 | 0.00 | 0 |
For data sources see[6]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2014 | CHEVRON APPALACHIA LLC | Drill Cuttings | 211.97 Tons | LANDFILL | 100419 |
2014 | CHEVRON APPALACHIA LLC | Drill Cuttings | 128.09 Tons | LANDFILL | 100172 |
2014 | CHEVRON APPALACHIA LLC | Fracing Fluid Waste | 20.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123SW001 |
2014 | CHEVRON APPALACHIA LLC | Drilling Fluid Waste | 62.40 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123SW001 |
2014 | CHEVRON APPALACHIA LLC | Drill Cuttings | 40.26 Tons | LANDFILL | 100592 |
2015 | CHEVRON APPALACHIA LLC | Drilling Fluid Waste | 208.50 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123SW001 |
2015 | CHEVRON APPALACHIA LLC | Drill Cuttings | 754.12 Tons | LANDFILL | 100419 |
2015 | CHEVRON APPALACHIA LLC | Drill Cuttings | 175.34 Tons | LANDFILL | 100172 |
2016 | CHEVRON APPALACHIA LLC | Fracturing Fluid Waste | 147.82 Tons | RESIDUAL WASTE TRANSFER FACILITY | 101532 |
2016 | CHEVRON APPALACHIA LLC | Fracturing Fluid Waste | 8,983.45 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016 | CHEVRON APPALACHIA LLC | Fracturing Fluid Waste | 24.00 Bbl | INJECTION DISPOSAL WELL | 34-059-24202 |
2016 | CHEVRON APPALACHIA LLC | Produced Fluid | 3,655.20 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123SW019 |
2016 | CHEVRON APPALACHIA LLC | Drilling Fluid Waste | 28.50 Bbl | RESIDUAL WASTE TRANSFER FACILITY | 101532 |
2016 | CHEVRON APPALACHIA LLC | Waste Water Treatment Sludge | 33.88 Tons | STORAGE PENDING DISPOSAL OR REUSE | MID0209062814 |
2016 | CHEVRON APPALACHIA LLC | Fracturing Fluid Waste | 154.51 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123SW019 |
2016 | CHEVRON APPALACHIA LLC | Fracturing Fluid Waste | 344.20 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123SW001 |
2016 | CHEVRON APPALACHIA LLC | Soil Contaminated by Oil & Gas Related Spills | 0.03 Tons | RESIDUAL WASTE TRANSFER FACILITY | 101532 |
2016 | CHEVRON APPALACHIA LLC | Drilling Fluid Waste | 62.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW001 |
2016 | CHEVRON APPALACHIA LLC | Synthetic Liner Materials | 3.69 Tons | LANDFILL | 100172 |
2016 | CHEVRON APPALACHIA LLC | Fracturing Fluid Waste | 71.53 Bbl | LANDFILL | 100172 |
2016 | CHEVRON APPALACHIA LLC | Fracturing Fluid Waste | 1,094.85 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW001 |
2016 | CHEVRON APPALACHIA LLC | Drilling Fluid Waste | 110.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123SW001 |
2016 | CHEVRON APPALACHIA LLC | Synthetic Liner Materials | 2.15 Tons | LANDFILL | 100663 |
2017 | CHEVRON APPALACHIA LLC | Produced Fluid | 360.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW001 |
2017 | CHEVRON APPALACHIA LLC | Produced Fluid | 57.00 Bbl | INJECTION DISPOSAL WELL | 34-119-28776 |
2017 | CHEVRON APPALACHIA LLC | Produced Fluid | 6,021.00 Bbl | INJECTION DISPOSAL WELL | 34-157-25511 |
2017 | CHEVRON APPALACHIA LLC | Produced Fluid | 4,754.90 Bbl | REUSE (AT WELL PAD) | |
2017 | CHEVRON APPALACHIA LLC | Produced Fluid | 417.69 Bbl | INJECTION DISPOSAL WELL | 34-059-24202 |
2017 | CHEVRON APPALACHIA LLC | Soil Contaminated by Oil | 0.08 Tons | RESIDUAL WASTE TRANSFER FACILITY | 101532 |
2017 | CHEVRON APPALACHIA LLC | Produced Fluid | 59.77 Bbl | RESIDUAL WASTE TRANSFER FACILITY | 101532 |
2017 | CHEVRON APPALACHIA LLC | Produced Fluid | 1,256.69 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2017 | CHEVRON APPALACHIA LLC | Soil Contaminated by Oil & Gas Related Spills | 0.08 Tons | RESIDUAL WASTE TRANSFER FACILITY | 101532 |
2017 | CHEVRON APPALACHIA LLC | Produced Fluid | 44.20 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2017 | CHEVRON APPALACHIA LLC | Produced Fluid | 6,769.67 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW019 |
2018 | CHEVRON APPALACHIA LLC | Produced Fluid | 319.50 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2018 | CHEVRON APPALACHIA LLC | Produced Fluid | 68.14 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW019 |
2018 | CHEVRON APPALACHIA LLC | Produced Fluid | 2,146.30 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2018 | CHEVRON APPALACHIA LLC | Produced Fluid | 443.50 Bbl | REUSE (AT WELL PAD) | |
2019 | CHEVRON APPALACHIA LLC | Produced Fluid | 732.50 Bbl | REUSE (AT WELL PAD) | |
2019 | CHEVRON APPALACHIA LLC | Produced Fluid | 63.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2019 | CHEVRON APPALACHIA LLC | Produced Fluid | 12.84 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW019 |
2019 | CHEVRON APPALACHIA LLC | Produced Fluid | 97.00 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA |
For data sources see[7]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2295598 | Primary Facility | 2014-08-14 | Drilling/Alteration | No Violations Noted | 26" conductor pipe set to 40' |
2304818 | Primary Facility | 2014-09-09 | Drilling/Alteration | No Violations Noted | CONDUCTOR SET. NO RIG ON SITE. |
2308673 | Primary Facility | 2014-09-19 | Drilling/Alteration | No Violations Noted | Highlands 14 top hole rig spud on 9/17/14; Drilled to 525'TD; Presently running 20" casing; report to follow; |
2308694 | Primary Facility | 2014-09-23 | Drilling/Alteration | No Violations Noted | on 9/20/14; drilled to 507'TD; Set 20" @ 502'; Cemented casing to surface; 21.5 bbls cmt returns; On 9/22 14; drilled to 996'TD; set 13 3/8"@ 955'; cemented to surface; 23 bbls cmt returns; |
2347063 | Primary Facility | 2015-01-14 | Routine/Complete Inspection | No Violations Noted | Well drilled to TD. Well waiting to be fracked. |
2373104 | Primary Facility | 2015-05-27 | Routine/Partial Inspection | No Violations Noted | |
2373859 | Primary Facility | 2015-03-20 | Drilling/Alteration | No Violations Noted | HORIZONTAL MARCELLUS, Pace drilling on air @ 2448' ( TD ). Running Intermediate Casing and cementing tonight 3/20/2015). |
2380224 | Primary Facility | 2015-06-04 | Routine/Complete Inspection | No Violations Noted | On 06/04/15 at approximately 1100 hours I conducted a routine complete inspection of the PBG Smith site. The Act 9 sign and all required documents were present at the site. The sides of the access road were well vegetated with few bare spots. The site was stabilized. The Nabors Drilling Rig #X07 was on site. There were no violations noted at the time of inspection. |
2402358 | Primary Facility | 2015-07-15 | Drilling/Alteration | No Violations Noted | HORIZONTAL MARCELLUS, Drilling on fluid @ 16,307' (TD). Setting 5 1/2" Prod. Casing and cementing tonight (7/14/2015). |
2444211 | Primary Facility | 2016-01-15 | Drilling/Alteration | No Violations Noted | HORIZONTAL MARCELLUS, Fracing crew starting stimulation of wells. |
2453640 | Primary Facility | 2015-12-31 | Routine/Complete Inspection | No Violations Noted | |
2463022 | Primary Facility | 2016-03-08 | Routine/Complete Inspection | No Violations Noted | On 03/08/16 at approximately 0830 I conducted an incident response inspection of the PBG Smith Unit. On 03/07/16 a spill of approximately 120 barrels of frack fluid occurred. The spill was reported as contained on secondary containment.
The Act 9 sign was in place and all required documents were present in the mailbox. The wells on site are currently being fracked. The containment appeared to be sound and appeared capable of containing the volume of fluid reported as released, due to a high berm on the edge of the containment. There were no signs that any fluid left containment. It is recommended that the area be inspected after containment is removed to verify that no fluid was outside of containment. |
2467432 | Primary Facility | 2016-03-24 | Administrative/File Review | No Violations Noted |
On 03/24/16 at approximately 1050 hours I conducted an administrative inspection in response to a spill at the Chevron PBG Smith well site. On 01/18/16 at approximately 0930 hours friction reducer was being circulated and a hose became disconnected allowing approximately 130 gallons of friction reducer to be spilled to containment. Operations were immediately shut down to prevent the additional release of fluid. The area was cleaned up in compliance with DEP spill policy. |
2479455 | Primary Facility | 2016-04-14 | Incident- Response to Accident or Event | No Violations Noted |
On 04/14/16 at approximately 0830 hours I conducted an incident response inspection in response to a spill that occurred on 04/13/16. The Act 9 sign was in place and all required documents were present at the site. On 04/13/16 a spill of 2/3 freshwater and 1/3 reuse water occurred. Approximately 55 barrels were recovered from containment. Chevron discovered that fluid leaked to the ground surface through a bad seam approximately 8” up the containment berm. After the fluid was recovered from the pad surface the faulty seam was repaired. The spill area off containment was excavated and the material placed on a liner and covered to prevent rain infiltration. Confirmatory samples were taken after excavation occurred. The spill volume to the ground was calculated at 30 gallons. |
2487667 | Primary Facility | 2016-05-25 | Drilling/Alteration | No Violations Noted | HORIZONTAL MARCELLUS, Fracing completed ,Rig moving on wells to drill out plugs and run tubing in well. |
2507825 | Primary Facility | 2016-06-06 | Routine/Complete Inspection | No Violations Noted |
On 06/06/16 at approximately 0900 hours I conducted a CEI in response to an NOV issued to Chevron Appalachia LLC for a discharge of approximately 30 gallons of brine fluid that passed through a bad seam in the containment and contacted the ground. The Act 9 sign was in place and all required documents were present in the mail box. The location of the spill had been excavated, filled, seeded, and mulched. Vegetation had begun to grow in the disturbed area. There were no signs of additional spills or discharges at the time of inspection. There were no violations observed. |
2525309 | Primary Facility | 2016-09-22 | Routine/Complete Inspection | No Violations Noted | On 09/22/16 at approximately 0900 hours I conducted a routine complete inspection of the PBG Smith Unit. The Act 9 sign was in place and all required documents were present at the site. The site was well stabilized and there were no signs of erosion observed at the time of inspection. There were no violations observed at the time of inspection. |
2549846 | Primary Facility | 2016-12-08 | Routine/Complete Inspection | No Violations Noted | On 12/08/16 at approximately 1100 hours I conducted a routine complete inspection of the PBG Smith Unit. The Act 9 sign was in place and all required documents were present at the site. The site was well stabilized and there were no signs of erosion observed at the time of inspection. It appeared that the AST equipment was being removed at the time of inspection. There were no violations observed at the time of inspection. |
2567842 | Primary Facility | 2017-03-06 | Routine/Complete Inspection | No Violations Noted | The Act 9 sign and all required documents were present at the site. The equipment appeared to be in good condition. The site was well vegetated and there were no signs of erosion observed. There were no violations observed at the time of inspection. |
2606069 | Primary Facility | 2017-06-21 | Routine/Complete Inspection | No Violations Noted | The Act 9 sign was in place and all required documents were present at the site. The site was well vegetated and there were no signs of erosion observed. The production equipment appeared to be in good condition. There were no violations observed at the time of inspection. |
2608772 | Primary Facility | 2017-06-21 | Routine/Complete Inspection | No Violations Noted | The Act 9 sign was in place and all required documents were present at the site. The site was well vegetated and there were no signs of erosion observed. The production equipment appeared to be in good condition. There were no violations observed at the time of inspection. |
2623521 | Primary Facility | 2017-08-07 | Routine/Complete Inspection | No Violations Noted | The Act 9 sign was in place and all required documents were present at the site. The site was well vegetated and there were no signs of erosion observed. The production equipment appeared to be in good condition. There were no violations observed at the time of inspection. |
2663885 | Primary Facility | 2017-11-16 | Routine/Complete Inspection | No Violations Noted | The Act 9 sign was in place and all required documents were present at the site. The AST pad appeared to have been recently restored. Some tire tracks were observed off the access road in the restored area. Aside from the tracks, the restored area and the rest of the site appeared to be well vegetated. The production equipment appeared to be in good condition. There were no violations observed at the time of inspection. |
2683493 | Primary Facility | 2018-01-10 | Routine/Complete Inspection | No Violations Noted | Well appears to be producing. Fencing Co. installing fence around storm water basin. |
2736957 | Primary Facility | 2018-06-04 | Routine/Complete Inspection | No Violations Noted | The Act 9 sign was in place and all required were present at the site. The production equipment appeared to be in good condition. The site overall was well vegetated. Perimeter BMPs had been removed and the area seeded and mulched. A small area off the southwest edge of the pad exhibited thin vegetation. It is recommended the area be seeded and mulched. A minor erosion rill was observed off the southwest edge of the pad in the direction of the basin. It is recommended the area be addressed, seeded, and mulched. |
2752495 | Primary Facility | 2018-07-17 | Routine/Complete Inspection | No Violations Noted | The Act 9 sign was in place and all required documents were present at the site. The site was well vegetated and there were no signs of erosion observed. A small erosion rill noted in previous inspections had been repaired. The production equipment appeared to be in good condition. There were no violations observed at the time of inspection. |
2798602 | Primary Facility | 2018-10-18 | Site Restoration | No Violations Noted | A site restoration inspection was conducted in response to an NOT submittal from Chevron. The Act 9 sign was in place and all required documents were present at the site. The site was well vegetated and exceeded uniform 70% vegetative cover. There were no signs of erosion observed. PCSM features were installed and appeared to be functioning. The NOT is approved. |
For data sources see[8]