37-059-26659

Well Details

Well ID: 37-059-26659
Loading map...
Country: United States
State: Pennsylvania
County: Greene
Municipality: Franklin Township
Operator Name: RICE DRILLING B LLC
Well Pad ID: 150450
Farm/Lease Name: PATTON
License Status: Active
Spud Date: 2014-10-17
Permit Date: 2014-09-22
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 39.913078
Longitude: -80.244169

For data sources see[1][2][3]

Well History

Date Event
2014-09-22 New Permit Application
2014-10-17 Performed Spud Operation
2015-02-27 New Permit Application

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2015-08-25 2015-09-10 7,818 7,381,630 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 WBO-2 Trican Breaker Sodium Persulfate 7775-27-1 75 0.00003514 24
40/70 Mesha Sand Trican Proppant Crystalline Silica in the form of Quartz 14808-60-7 100 4.459 3,045,780.0
FEAC-20 Trican Iron Control Cirtic Acid 77-92-9 27 0.000906916 619.481
Acetic Acid 64-19-7 45 0.00151153 1032.47
FR-20 Trican Friction Reducer Oleic Acid Diethanolamide 93-83-4 1 0.000560065 382.56
Water 7732-18-5 43 0.0240828 16450.1
Distillates (Petroleum), Hydrotreated Light 64742-47-8 17 0.0095211 6503.52
Ammonium Chloride 12125-02-9 0.9 0.000504058 344.304
Alcohols, C12-16, Ethoxylated 68551-12-2 1 0.000560065 382.56
Polyacrylamide 69418-26-4 25 0.0140016 9564
7.5% HCL Trican ACID HYDROCLORIC ACID 7647-01-0 7.5 0.0443111 30267.3
Biocide X-Chem Biocide Chlorine Dioxide 10049-04-4 0.4 0.00002426 16.573
WG-111L Trican Viscosifier, Gel Light Hydrotreated Petroleum Distillate 64742-47-8 45 0.00309985 2117.4
Polysaccharide blend NA 45 0.00309985 2117.4
SC-30 X-Chem Scale Inhibitor Sodium Hydroxide 1310-73-2 1.5 0.000161596 110.381
Al-11 Trican Corrosion Inhibitor Propargly Alcohol 107-19-7 0.9 0.00001539 10.515
Propargyl Alcohol Deritative NA 45 0.000769672 525.735
Potassium Iodide 7681-11-0 3.5 0.00005986 40.891
WATER VANTAGE WATER WATER NA 100 90.1815 61,599,700.0
100 Mesh Trican Proppant Crystalline Silica in the form of Quartz 14808-60-7 100 4.68387 3,199,380.0

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2014 VANTAGE ENERGY APPALACHIA II LLC 0.00 0 0.00 0 0.00 0
2015 VANTAGE ENERGY APPALACHIA II LLC 460,130.99 59 0.00 0 0.00 0
2016 VANTAGE ENERGY APPALACHIA II LLC 1,431,665.92 274 0.00 0 0.00 0
2017 RICE DRILLING B LLC 877,129.07 354 0.00 0 0.00 0
2018 RICE DRILLING B LLC 572,663.00 311 0.00 0 0.00 0
2019 RICE DRILLING B LLC 404,041.00 297 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2014 VANTAGE ENERGY APPALACHIA II LLC Drill Cuttings 455.94 Tons LANDFILL 100419
2015 VANTAGE ENERGY APPALACHIA II LLC Drilling Fluid Waste 226.67 Bbl REUSE OTHER THAN ROAD SPREADING
2015 VANTAGE ENERGY APPALACHIA II LLC Drilling Fluid Waste 412.50 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW001
2015 VANTAGE ENERGY APPALACHIA II LLC Fracing Fluid Waste 30.00 Bbl RESIDUAL WASTE TRANSFER FACILITY 101532
2015 VANTAGE ENERGY APPALACHIA II LLC Drill Cuttings 331.11 Tons LANDFILL 100419
2015 VANTAGE ENERGY APPALACHIA II LLC Fracturing Fluid Waste 10.00 Tons RESIDUAL WASTE TRANSFER FACILITY 101532
2015 VANTAGE ENERGY APPALACHIA II LLC Fracing Fluid Waste 11,115.67 Bbl REUSE OTHER THAN ROAD SPREADING
2015 VANTAGE ENERGY APPALACHIA II LLC Drill Cuttings 39.97 Tons RESIDUAL WASTE TRANSFER FACILITY 301071
2015 VANTAGE ENERGY APPALACHIA II LLC Fracing Fluid Waste 1,714.17 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW010
2015 VANTAGE ENERGY APPALACHIA II LLC Drill Cuttings 335.38 Tons LANDFILL PAD059087072
2015 VANTAGE ENERGY APPALACHIA II LLC Drilling Fluid Waste 263.87 Bbl INJECTION DISPOSAL WELL 34-059-24202
2015 VANTAGE ENERGY APPALACHIA II LLC Drilling Fluid Waste 73.33 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW010
2015 VANTAGE ENERGY APPALACHIA II LLC Fracing Fluid Waste 27.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW001
2015 VANTAGE ENERGY APPALACHIA II LLC Produced Fluid 1,422.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016 VANTAGE ENERGY APPALACHIA II LLC Fracturing Fluid Waste 32.36 Bbl RESIDUAL WASTE TRANSFER FACILITY 101532
2016 VANTAGE ENERGY APPALACHIA II LLC Other Oil & Gas Wastes 1,765.50 Bbl REUSE OTHER THAN ROAD SPREADING
2016 VANTAGE ENERGY APPALACHIA II LLC Produced Fluid 213.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW010
2016 VANTAGE ENERGY APPALACHIA II LLC Produced Fluid 21,973.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016 VANTAGE ENERGY APPALACHIA II LLC Produced Fluid 1,873.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW001
2016 VANTAGE ENERGY APPALACHIA II LLC Fracturing Fluid Waste 2.68 Tons LANDFILL 100620
2016 VANTAGE ENERGY APPALACHIA II LLC Produced Fluid 68.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2016 VANTAGE ENERGY APPALACHIA II LLC Produced Fluid 250.00 Bbl INJECTION DISPOSAL WELL 34-119-28776
2016 VANTAGE ENERGY APPALACHIA II LLC Other Oil & Gas Wastes 189.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW001
2016 VANTAGE ENERGY APPALACHIA II LLC Synthetic Liner Materials 1.80 Tons LANDFILL 100620
2016 VANTAGE ENERGY APPALACHIA II LLC Soil Contaminated by Oil & Gas Related Spills 5.07 Tons LANDFILL 100172
2016 VANTAGE ENERGY APPALACHIA II LLC Servicing Fluid 19.00 Tons REUSE OTHER THAN ROAD SPREADING
2016 VANTAGE ENERGY APPALACHIA II LLC Produced Fluid 150.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW001
2016 VANTAGE ENERGY APPALACHIA II LLC Produced Fluid 122.00 Bbl INJECTION DISPOSAL WELL 34-167-23862
2017 VANTAGE ENERGY APPALACHIA II LLC Soil Contaminated by Oil & Gas Related Spills 0.08 Tons RESIDUAL WASTE PROCESSING FACILITY 301280
2017 RICE DRILLING B LLC Produced Fluid 9.09 Bbl RESIDUAL WASTE PROCESSING FACILITY
2017 RICE DRILLING B LLC Soil Contaminated by Oil & Gas Related Spills 0.54 Tons LANDFILL CID # 28726
2017 VANTAGE ENERGY APPALACHIA II LLC Synthetic Liner Materials 7.93 Tons LANDFILL 100663
2017 VANTAGE ENERGY APPALACHIA II LLC Filter Socks 0.08 Tons RESIDUAL WASTE PROCESSING FACILITY 301280
2017 VANTAGE ENERGY APPALACHIA II LLC Soil Contaminated by Oil 2.66 Tons RESIDUAL WASTE TRANSFER FACILITY 101532
2017 VANTAGE ENERGY APPALACHIA II LLC Other Oil & Gas Wastes 259.10 Bbl REUSE (AT WELL PAD)
2017 VANTAGE ENERGY APPALACHIA II LLC Other Oil & Gas Wastes 25.59 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2017 VANTAGE ENERGY APPALACHIA II LLC Filter Socks 0.08 Tons RESIDUAL WASTE PROCESSING FACILITY 2014-541
2017 VANTAGE ENERGY APPALACHIA II LLC Produced Fluid 3,611.36 Bbl REUSE (AT WELL PAD)
2017 VANTAGE ENERGY APPALACHIA II LLC Waste Water Treatment Sludge 2.50 Tons RESIDUAL WASTE PROCESSING FACILITY 2014-541
2017 VANTAGE ENERGY APPALACHIA II LLC Produced Fluid 12.75 Tons LANDFILL 100172
2017 VANTAGE ENERGY APPALACHIA II LLC Other Oil & Gas Wastes 123.72 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2017 VANTAGE ENERGY APPALACHIA II LLC Soil Contaminated by Oil 0.08 Tons RESIDUAL WASTE PROCESSING FACILITY 301280
2017 VANTAGE ENERGY APPALACHIA II LLC Waste Water Treatment Sludge 3.85 Tons RESIDUAL WASTE TRANSFER FACILITY 101532
2017 RICE DRILLING B LLC Produced Fluid 10.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW009
2017 VANTAGE ENERGY APPALACHIA II LLC Produced Fluid 1.27 Bbl RESIDUAL WASTE TRANSFER FACILITY 101532
2017 VANTAGE ENERGY APPALACHIA II LLC Soil Contaminated by Oil & Gas Related Spills 2.66 Tons RESIDUAL WASTE TRANSFER FACILITY 101532
2017 VANTAGE ENERGY APPALACHIA II LLC Drilling Fluid Waste 7.27 Bbl REUSE (AT WELL PAD)
2017 VANTAGE ENERGY APPALACHIA II LLC Produced Fluid 870.83 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2017 RICE DRILLING B LLC Produced Fluid 9.80 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW010
2017 VANTAGE ENERGY APPALACHIA II LLC Produced Fluid 1,500.84 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2017 RICE DRILLING B LLC Soil Contaminated by Oil 0.54 Tons LANDFILL CID # 28726
2018 RICE DRILLING B LLC Produced Fluid 1.00 Tons RESIDUAL WASTE PROCESSING FACILITY 2014-541
2018 RICE DRILLING B LLC Produced Fluid 161.39 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2018 RICE DRILLING B LLC Synthetic Liner Materials 2.59 Tons LANDFILL 100419
2018 RICE DRILLING B LLC Produced Fluid 14.04 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018 RICE DRILLING B LLC Other Oil & Gas Wastes 115.45 Bbl REUSE (AT WELL PAD)
2018 RICE DRILLING B LLC Produced Fluid 109.32 Bbl REUSE (AT WELL PAD)
2019 RICE DRILLING B LLC Other Oil & Gas Wastes 20.00 Bbl SURFACE IMPOUNDMENT 95-7-37312-19
2019 RICE DRILLING B LLC Other Oil & Gas Wastes 116.38 Bbl REUSE (AT WELL PAD)
2019 RICE DRILLING B LLC Produced Fluid 255.80 Bbl REUSE (AT WELL PAD)
2019 RICE DRILLING B LLC Produced Fluid 42.94 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW010
2019 RICE DRILLING B LLC Produced Fluid 9.92 Bbl SURFACE IMPOUNDMENT 95-7-37312-19
2019 RICE DRILLING B LLC Produced Fluid 4.74 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2320297 Primary Facility 2014-10-28 Drilling/Alteration No Violations Noted CONDUCTOR SET 40' OF 20". YOST RIG 10 ON SITE DRILLING TOP HOLE SETS.
2334473 Primary Facility 2014-10-14 Routine/Complete Inspection No Violations Noted Well not drilled, pre-spud inspection.
2338524 Primary Facility 2014-10-29 Routine/Complete Inspection No Violations Noted Well conductor set, well being drilled.
2465826 Primary Facility 2016-03-18 Administrative/File Review In Compliance with Policy An estimated 5 to 10 gallons of brine was released from a breeched T connection within a GPU at the Patton Well Site. The release occurred entirely within containment, therefore no soil or water impacts resulted. The material was removed from containment via a vacuum and in situ testing was conducted to confirm remediation. All associated equipment was replaced and/or repaired. The matter has been determined to be In Compliance with Policy (ICP). No violations are being cited at this time.
2479201 Primary Facility 2016-04-21 Incident- Response to Accident or Event No Violations Noted An estimated 200 gallons of brine was released from a broken site tube on a water truck leaving the Patton Well Site in Franklin Township, Greene County. The release impacted part of the access road between Throckmorton Run and the gate, as well as a few hundred feet of asphalt pavement on Hill School House Road and several areas of compacted gravel berm along the road. Notifications were made, personnel mobilized and the impacted areas remediated.

The failure to contain the brine release is a violation of Title 25 Pa. Code § 91.34(a). The impact to soils resulting from the release of brine is a violation of the Clean Streams Law 35 P.S. § 691.401.

2498657 Primary Facility 2016-06-08 Compliance Evaluation No Violations Noted On Wednesday June 8, 2016, I conducted a compliance evaluation inspection at the Patton Well Site located in Franklin Township, Greene County. The inspection was performed to review remediation work completed in association with an April 21, 2016 brine release in which approximately 200 gallons of brine was released and had impacted the ground surface.
2514690 Primary Facility 2016-08-09 Incident- Response to Accident or Event In Compliance with Policy An incident response conducted as a result of an operator notification.
2514752 Primary Facility 2016-08-09 Incident- Response to Accident or Event In Compliance with Policy An incident response conducted as a result of an operator notification.
2515741 Primary Facility 2016-08-09 Routine/Complete Inspection No Violations Noted Well properly identified and equipped for production. Operator currently drilling Patton 15H well. (059-27057).
2515885 Primary Facility 2016-08-12 Incident- Response to Accident or Event In Compliance with Policy An incident response conducted as a result of an operator notification.
2516587 Primary Facility 2016-08-30 Incident- Response to Accident or Event In Compliance with Policy An incident response conducted as a result of an operator notification.
2549020 Primary Facility 2016-10-15 Administrative/File Review In Compliance with Policy

On 10/15/16 at approximately 1200 hours I completed an administrative inspection in response to a release at the Patton pad. A spill out of containment of approximately 1 barrel of water and drilling cuttings was reported, but an accurate volume could not be determined due to rain water being present on the containment. Weavertown Environmental performed the cleanup of the site. SE Technologies LLC submitted a letter on Vantage’s behalf requesting that the Act 2 process be waived, due to the inconclusive volume released and low conductivity levels. The Department determined that the evidence provided was reasonable and has permitted Vantage to continue without the Act 2 process. The spill was handled in compliance with DEP policy.

2550435 Primary Facility 2016-12-27 Routine/Complete Inspection No Violations Noted

On 12/27/16 at approximately 1030 hours I conducted a routine complete inspection of the Patton Unit. The Act 9 sign was in place and all required documents were present at the site.

A U shape of sediment sock had been placed immediately adjacent to the first stream crossing to serve as an infiltration berm for water eroding the road surface. It is highly recommended that the road be repaired and the material stopped by the sock removed to prevent a BMP failure at the stream.

The GPUs were found to be in secondary containment consistent with Chapter 78A.64b which requires equipment containing regulated substances to be placed within secondary containment.

The site overall was well vegetated and no signs of erosion were observed at the time of inspection with the exception of the road surface.

For data sources see[8]

References