Well Details

Well ID: 37-059-26742
Loading map...
Country: United States
State: Pennsylvania
County: Greene
Municipality: Franklin Township
Operator Name: RICE DRILLING B LLC
Well Pad ID: 150450
Farm/Lease Name: PATTON
License Status: Active
Spud Date: 2015-01-08
Permit Date: 2014-12-15
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 39.913011
Longitude: -80.244053

For data sources see[1][2][3]

Well History

Date Event
2014-12-15 New Permit Application
2015-01-08 Performed Spud Operation
2015-02-27 New Permit Application

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2015-08-24 2015-09-09 7,807 7,560,880 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 100 Mesh Trican Proppant Crystalline Silica in the form of Quartz 14808-60-7 100 4.86124 3,414,710.0
FR-20 Trican Friction Reducer Water 7732-18-5 43 0.0243358 17094.4
Polyacrylamide 69418-26-4 25 0.0141487 9938.58
Alcohols, C12-16, Ethoxylated 68551-12-2 1 0.000565949 397.543
Ammonium Chloride 12125-02-9 0.9 0.000509354 357.789
Oleic Acid Diethanolamide 93-83-4 1 0.000565949 397.543
Distillates (Petroleum), Hydrotreated Light 64742-47-8 17 0.00962114 6758.24
7.5% HCL Trican ACID HYDROCLORIC ACID 7647-01-0 7.5 0.0479771 33700.9
SC-30 X-Chem Scale Inhibitor Sodium Hydroxide 1310-73-2 1.5 0.000151895 106.697
Al-11 Trican Corrosion Inhibitor Propargly Alcohol 107-19-7 0.9 0.00001657 11.641
Potassium Iodide 7681-11-0 3.5 0.00006445 45.272
Propargyl Alcohol Deritative NA 45 0.000828636 582.064
Biocide X-Chem Biocide Chlorine Dioxide 10049-04-4 0.4 0.00007624 53.551
WATER VANTAGE WATER WATER NA 100 89.8239 63,095,600.0
40/70 Mesha Sand Trican Proppant Crystalline Silica in the form of Quartz 14808-60-7 100 4.58393 3,219,920.0
FEAC-20 Trican Iron Control Cirtic Acid 77-92-9 27 0.000980313 688.608
Acetic Acid 64-19-7 45 0.00163386 1147.68

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2015 VANTAGE ENERGY APPALACHIA II LLC 466,991.46 59 0.00 0 0.00 0
2016 VANTAGE ENERGY APPALACHIA II LLC 1,623,456.36 276 0.00 0 0.00 0
2017 RICE DRILLING B LLC 924,078.90 355 0.00 0 0.00 0
2018 RICE DRILLING B LLC 626,320.00 351 0.00 0 0.00 0
2019 RICE DRILLING B LLC 364,837.00 178 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2015 VANTAGE ENERGY APPALACHIA II LLC Drilling Fluid Waste 226.67 Bbl REUSE OTHER THAN ROAD SPREADING
2015 VANTAGE ENERGY APPALACHIA II LLC Drilling Fluid Waste 312.50 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW001
2015 VANTAGE ENERGY APPALACHIA II LLC Fracing Fluid Waste 30.00 Bbl RESIDUAL WASTE TRANSFER FACILITY 101532
2015 VANTAGE ENERGY APPALACHIA II LLC Drill Cuttings 955.99 Tons LANDFILL 100419
2015 VANTAGE ENERGY APPALACHIA II LLC Fracing Fluid Waste 11,015.67 Bbl REUSE OTHER THAN ROAD SPREADING
2015 VANTAGE ENERGY APPALACHIA II LLC Fracturing Fluid Waste 10.00 Tons RESIDUAL WASTE TRANSFER FACILITY 101532
2015 VANTAGE ENERGY APPALACHIA II LLC Drilling Fluid Waste 200.00 Bbl INJECTION DISPOSAL WELL 34-155-23732
2015 VANTAGE ENERGY APPALACHIA II LLC Fracing Fluid Waste 1,714.17 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW010
2015 VANTAGE ENERGY APPALACHIA II LLC Drill Cuttings 351.35 Tons LANDFILL PAD059087072
2015 VANTAGE ENERGY APPALACHIA II LLC Drilling Fluid Waste 448.85 Bbl INJECTION DISPOSAL WELL 34-059-24202
2015 VANTAGE ENERGY APPALACHIA II LLC Drilling Fluid Waste 73.33 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW010
2015 VANTAGE ENERGY APPALACHIA II LLC Fracing Fluid Waste 27.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW001
2015 VANTAGE ENERGY APPALACHIA II LLC Produced Fluid 1,226.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016 VANTAGE ENERGY APPALACHIA II LLC Fracturing Fluid Waste 32.36 Bbl RESIDUAL WASTE TRANSFER FACILITY 101532
2016 VANTAGE ENERGY APPALACHIA II LLC Other Oil & Gas Wastes 1,765.50 Bbl REUSE OTHER THAN ROAD SPREADING
2016 VANTAGE ENERGY APPALACHIA II LLC Other Oil & Gas Wastes 189.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW001
2016 VANTAGE ENERGY APPALACHIA II LLC Produced Fluid 227.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW010
2016 VANTAGE ENERGY APPALACHIA II LLC Produced Fluid 19,657.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016 VANTAGE ENERGY APPALACHIA II LLC Produced Fluid 1,323.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW001
2016 VANTAGE ENERGY APPALACHIA II LLC Fracturing Fluid Waste 2.68 Tons LANDFILL 100620
2016 VANTAGE ENERGY APPALACHIA II LLC Synthetic Liner Materials 1.80 Tons LANDFILL 100620
2016 VANTAGE ENERGY APPALACHIA II LLC Soil Contaminated by Oil & Gas Related Spills 5.07 Tons LANDFILL 100172
2016 VANTAGE ENERGY APPALACHIA II LLC Servicing Fluid 19.00 Tons REUSE OTHER THAN ROAD SPREADING
2016 VANTAGE ENERGY APPALACHIA II LLC Produced Fluid 68.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2016 VANTAGE ENERGY APPALACHIA II LLC Produced Fluid 150.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW001
2016 VANTAGE ENERGY APPALACHIA II LLC Produced Fluid 182.00 Bbl INJECTION DISPOSAL WELL 34-167-23862
2017 VANTAGE ENERGY APPALACHIA II LLC Soil Contaminated by Oil & Gas Related Spills 0.08 Tons RESIDUAL WASTE PROCESSING FACILITY 301280
2017 RICE DRILLING B LLC Produced Fluid 9.09 Bbl RESIDUAL WASTE PROCESSING FACILITY
2017 RICE DRILLING B LLC Soil Contaminated by Oil & Gas Related Spills 0.54 Tons LANDFILL CID # 28726
2017 VANTAGE ENERGY APPALACHIA II LLC Synthetic Liner Materials 7.93 Tons LANDFILL 100663
2017 VANTAGE ENERGY APPALACHIA II LLC Filter Socks 0.08 Tons RESIDUAL WASTE PROCESSING FACILITY 301280
2017 VANTAGE ENERGY APPALACHIA II LLC Soil Contaminated by Oil 2.66 Tons RESIDUAL WASTE TRANSFER FACILITY 101532
2017 VANTAGE ENERGY APPALACHIA II LLC Other Oil & Gas Wastes 259.10 Bbl REUSE (AT WELL PAD)
2017 VANTAGE ENERGY APPALACHIA II LLC Other Oil & Gas Wastes 25.59 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2017 VANTAGE ENERGY APPALACHIA II LLC Filter Socks 0.08 Tons RESIDUAL WASTE PROCESSING FACILITY 2014-541
2017 VANTAGE ENERGY APPALACHIA II LLC Produced Fluid 3,947.51 Bbl REUSE (AT WELL PAD)
2017 VANTAGE ENERGY APPALACHIA II LLC Waste Water Treatment Sludge 2.50 Tons RESIDUAL WASTE PROCESSING FACILITY 2014-541
2017 VANTAGE ENERGY APPALACHIA II LLC Other Oil & Gas Wastes 123.72 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2017 VANTAGE ENERGY APPALACHIA II LLC Produced Fluid 12.75 Tons LANDFILL 100172
2017 VANTAGE ENERGY APPALACHIA II LLC Soil Contaminated by Oil 0.08 Tons RESIDUAL WASTE PROCESSING FACILITY 301280
2017 VANTAGE ENERGY APPALACHIA II LLC Waste Water Treatment Sludge 3.85 Tons RESIDUAL WASTE TRANSFER FACILITY 101532
2017 RICE DRILLING B LLC Produced Fluid 10.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW009
2017 VANTAGE ENERGY APPALACHIA II LLC Produced Fluid 1.27 Bbl RESIDUAL WASTE TRANSFER FACILITY 101532
2017 VANTAGE ENERGY APPALACHIA II LLC Soil Contaminated by Oil & Gas Related Spills 2.66 Tons RESIDUAL WASTE TRANSFER FACILITY 101532
2017 VANTAGE ENERGY APPALACHIA II LLC Drilling Fluid Waste 7.27 Bbl REUSE (AT WELL PAD)
2017 VANTAGE ENERGY APPALACHIA II LLC Produced Fluid 870.83 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2017 RICE DRILLING B LLC Produced Fluid 9.80 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW010
2017 VANTAGE ENERGY APPALACHIA II LLC Produced Fluid 1,500.84 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2017 RICE DRILLING B LLC Soil Contaminated by Oil 0.54 Tons LANDFILL CID # 28726
2018 RICE DRILLING B LLC Produced Fluid 173.77 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2018 RICE DRILLING B LLC Produced Fluid 14.91 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018 RICE DRILLING B LLC Other Oil & Gas Wastes 115.45 Bbl REUSE (AT WELL PAD)
2018 RICE DRILLING B LLC Produced Fluid 182.91 Bbl REUSE (AT WELL PAD)
2019 RICE DRILLING B LLC Other Oil & Gas Wastes 20.00 Bbl SURFACE IMPOUNDMENT 95-7-37312-19
2019 RICE DRILLING B LLC Other Oil & Gas Wastes 116.38 Bbl REUSE (AT WELL PAD)
2019 RICE DRILLING B LLC Produced Fluid 177.16 Bbl REUSE (AT WELL PAD)

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2347926 Primary Facility 2015-02-26 Drilling/Alteration No Violations Noted Well has been topholed and covered waiting on Lateral rig to drill laterals; setting surface equipment at this time; location is snowcovered;
2408242 Primary Facility 2015-09-17 Incident- Response to Accident or Event Violation(s) Noted On 9/17/2015, I performed an inspection of Vantage Energy Patton well pad site. Present at time of inspection was Doug Wilson, Jerry DeRosa, Lou Schall (Vantage Energy), Josh George (Rockwater), and Noel Messing (SE Tech). The site is located in Franklin Twp., Greene County. The inspection was performed as a response to a reported spill by the operator.
2411318 Primary Facility 2015-08-24 Routine/Complete Inspection No Violations Noted On 8/24/2015, I performed an inspection of Vantage Energy's Patton well pad site. The site is located in Franklin Twp., Greene County. Present at time of inspection was Noel Messig (SE). The inspection was performed as a routine inspection of site during hydraulic fracturing operations, because of report of a spill by the operator.
2414699 Primary Facility 2015-10-05 Compliance Evaluation No Violations Noted On 10/5/2015, I performed an inspection of Vantage Energy's Patton well pad site. The site is located in Franklin Twp., Greene County. Present at time of inspection was Jerry DeRosa (Vantage), and Tim Ratvasky (SE Tech). The inspection was performed as a compliance evaluation inspection of site during production setup, because of a spill on 9/16/15.
2465827 Primary Facility 2016-03-18 Administrative/File Review In Compliance with Policy An estimated 5 to 10 gallons of brine was released from a breeched T connection within a GPU at the Patton Well Site. The release occurred entirely within containment, therefore no soil or water impacts resulted. The material was removed from containment via a vacuum and in situ testing was conducted to confirm remediation. All associated equipment was replaced and/or repaired. The matter has been determined to be In Compliance with Policy (ICP). No violations are being cited at this time.
2479204 Primary Facility 2016-04-21 Incident- Response to Accident or Event No Violations Noted An estimated 200 gallons of brine was released from a broken site tube on a water truck leaving the Patton Well Site in Franklin Township, Greene County. The release impacted part of the access road between Throckmorton Run and the gate, as well as a few hundred feet of asphalt pavement on Hill School House Road and several areas of compacted gravel berm along the road. Notifications were made, personnel mobilized and the impacted areas remediated.

The failure to contain the brine release is a violation of Title 25 Pa. Code § 91.34(a). The impact to soils resulting from the release of brine is a violation of the Clean Streams Law 35 P.S. § 691.401.

2498660 Primary Facility 2016-06-08 Compliance Evaluation No Violations Noted On Wednesday June 8, 2016, I conducted a compliance evaluation inspection at the Patton Well Site located in Franklin Township, Greene County. The inspection was performed to review remediation work completed in association with an April 21, 2016 brine release in which approximately 200 gallons of brine was released and had impacted the ground surface.
2514691 Primary Facility 2016-08-09 Incident- Response to Accident or Event In Compliance with Policy An incident response conducted as a result of an operator notification.
2514753 Primary Facility 2016-08-09 Incident- Response to Accident or Event In Compliance with Policy An incident response conducted as a result of an operator notification.
2515742 Primary Facility 2016-08-09 Routine/Complete Inspection No Violations Noted Well properly identified and equipped for production. Operator currently drilling Patton 15H well. (059-27057).
2515888 Primary Facility 2016-08-12 Incident- Response to Accident or Event In Compliance with Policy An incident response conducted as a result of an operator notification.
2516588 Primary Facility 2016-08-30 Incident- Response to Accident or Event In Compliance with Policy An incident response conducted as a result of an operator notification.
2549021 Primary Facility 2016-10-15 Administrative/File Review In Compliance with Policy

On 10/15/16 at approximately 1200 hours I completed an administrative inspection in response to a release at the Patton pad. A spill out of containment of approximately 1 barrel of water and drilling cuttings was reported, but an accurate volume could not be determined due to rain water being present on the containment. Weavertown Environmental performed the cleanup of the site. SE Technologies LLC submitted a letter on Vantage’s behalf requesting that the Act 2 process be waived, due to the inconclusive volume released and low conductivity levels. The Department determined that the evidence provided was reasonable and has permitted Vantage to continue without the Act 2 process. The spill was handled in compliance with DEP policy.

2550436 Primary Facility 2016-12-27 Routine/Complete Inspection No Violations Noted

On 12/27/16 at approximately 1030 hours I conducted a routine complete inspection of the Patton Unit. The Act 9 sign was in place and all required documents were present at the site.

A U shape of sediment sock had been placed immediately adjacent to the first stream crossing to serve as an infiltration berm for water eroding the road surface. It is highly recommended that the road be repaired and the material stopped by the sock removed to prevent a BMP failure at the stream.

The GPUs were found to be in secondary containment consistent with Chapter 78A.64b which requires equipment containing regulated substances to be placed within secondary containment.

The site overall was well vegetated and no signs of erosion were observed at the time of inspection with the exception of the road surface.

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
2408242 735013 09/17/2015 2015-09-17 78.54 - GENERAL REQUIREMENTS - Operator failed to control and dispose of fluids, residual waste and drill cuttings, including tophole water, brines, drilling fluids, drilling muds, stimulation fluids, well servicing fluids, oil, and production fluids Environmental Health & Safety

Penalties Applied

Violation ID Penalty ID Penalty Code Penalty Status Penalty Date Enforcement Date Penalty Amount Amount Collected
735013 329663 NOV - Notice of Violation Superseded 2016-03-07
735013 340488 CACP - Consent Assessment of Civil Penalty Comply/Closed 2016-03-07 2016-03-07 $9,000.00 $9,000.00

For data sources see[8]

References