Well Details

Well ID: 37-063-22468
Loading map...
Country: United States
State: Pennsylvania
County: Indiana
Municipality: Banks Township
Operator Name: ALLIANCE PETRO CO LLC
Well Pad ID:
Farm/Lease Name: RUELBA L STEEL WN1327
License Status: ACTIVE
Spud Date: 1974-07-23
Permit Date: 1974-02-15
Well Type: GAS
Unconventional Well: N
Configuration: Vertical Well
Conservation: No
Latitude: 40.882095
Longitude: -78.851502

For data sources see[1][2][3]

Well History

Date Event
1974-02-15 New Permit Application
1974-07-23 Performed Spud Operation
1974-07-30 Drilling Completion
1974-08-06 Perforation
1974-09-16 NEWLY DRILLED

For data sources see[4]


Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
1994 DOMINION ENERGY TRANS INC 2347.00 365 0.00 0 0.00 0
1996 DOMINION ENERGY TRANS INC 2865 365 0.00 0 0.00 0
1997 DOMINION ENERGY TRANS INC 2637 365 0.00 0 0.00 0
1998 DOMINION ENERGY TRANS INC 3212 334 0.00 0 0.00 0
1999 DOMINION ENERGY TRANS INC 2300 365 0.00 0 0.00 0
2000 DOMINION ENERGY TRANS INC 2424 366 0.00 0 0.00 0
2001 DOMINION ENERGY TRANS INC 2201 365 0.00 0 0.00 0
2002 DOMINION ENERGY TRANS INC 2622 365 0.00 0 0.00 0
2003 DOMINION ENERGY TRANS INC 1958 365 0.00 0 0.00 0
2004 DOMINION ENERGY TRANS INC 1124 276 0.00 0 0.00 0
2005 DOMINION ENERGY TRANS INC 1652 365 0.00 0 0.00 0
2006 DOMINION ENERGY TRANS INC 2,062.00 365 0.00 0 0.00 0
2007 DOMINION ENERGY TRANS INC 1236.00 304 0.00 0 0.00 0
2008 DOMINION ENERGY TRANS INC 1525.00 366 0.00 0 0.00 0
2009 DOMINION ENERGY TRANS INC 1152.00 276 0.00 0 0.00 0
2010 DOMINION ENERGY TRANS INC 0.00 0 0.00 0 0.00 0
2011 DOMINION ENERGY TRANS INC 0.00 0 0.00 0 0.00 0
2012 DOMINION ENERGY TRANS INC 0.00 0 0.00 0 0.00 0
2013 CNX GAS CO LLC 1,195.08 365 0.00 0 0.00 0
2014 CNX GAS CO LLC 1,053.38 365 0.00 0 0.00 0
2015 CNX GAS CO LLC 1,159.99 365 0.00 0 0.00 0
2016 CNX GAS CO LLC 929.81 366 0.00 0 0.00 0
2017 CNX GAS CO LLC 912.26 334 0.00 0 0.00 0
2018 CNX GAS CO LLC 0.00 0 0.00 0 0.00 0
2019 ALLIANCE PETRO CO LLC 838.00 184 0.00 0 0.00 0

For data sources see[5]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
1996 DOMINION ENERGY TRANS INC Brine 27.00 Bbl Treated On-Site, NPDES Discharge PA0101656
1998 DOMINION ENERGY TRANS INC Brine 60.00 Bbl Brine or Industrial Waste Treatment Plt 0101656
1999 DOMINION ENERGY TRANS INC Brine 35.00 Bbl Brine or Industrial Waste Treatment Plt PA0101656
2004 DOMINION ENERGY TRANS INC Brine 70.00 Bbl Treated On-Site, NPDES Discharge PA0101508
2009 DOMINION ENERGY TRANS INC Brine 70.00 Bbl Brine or Industrial Waste Treatment Plt PA0101656
2014 CNX GAS CO LLC Produced Fluid 43.00 Bbl INJECTION DISPOSAL WELL 34-133-20525

For data sources see[6]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2448023 Primary Facility 2016-02-04 Routine/Complete Inspection Violation(s) Noted At time of inspection well tag present. BT appears structurally sound. AR gated. Culvert pipe nearest the AR gate appears to be filled with sediment. As a result, it appears that the water intended for the culvet pipe is flooding the roadway creating erosion gullies. Dept contacted Opr Rep Spenser Johnson by phone. Opr stated he would send a field rep out immediately.Opr Rep Richie Vrobel contacted Dept by phone at 15:53. He stated the culvert was cleaned and water was running through it. Opr was sending field personel out tomorrow (2-5-16) to do additional work at/near culvert and along AR in order to ensure culvert pipe is functioning properly. Opr intends to utilize heavy equipment to fix road when weather improves. Dept recommends Opr continue to monitor and maintain AR. A follow up inspection will be conducted to ensure culvert pipe is functioning properly and E&S issues are addressed.Violations being issued for failure to maintain BMP's and for failure to minimize accerated erosion and sedimentation.
2461736 Primary Facility 2016-02-25 Follow-up Inspection Outstanding Violations - No Viols Req'd Follow up inspection to Inspection Record # 2448023 where violations exist for failure to maintain BMP's and failure to minimize accerated erosion and sedimentation.

At time of inspection culvert pipe appears cleaned out and appears functional. No water crossing access road at or near culvert pipe. Department recommends Operator continue to monitor and maintain access road and culvert pipe to avoid any E&S issues. A follow up inspection will be conducted at a later date. Violations are still outstanding for this site.

2471861 Primary Facility 2016-03-24 Routine/Partial Inspection Outstanding Violations - No Viols Req'd Inspection due to an Operator requested site meeting. RTPT inspection to Inspection Record #2448023 where violation issued for failure to maintain BMP's and failure to minimize erosion/sedimentation.

Present during inspection: CNX Foreman Richie Vrobel, CNX Reps Will Roupe and Alex Molnar, DEP Biologist Supervisor Mike Stephan and DEP Biologist Will Brogan. Operator outlined projected plans for replacing current culvert which failed causing violations to be issued on 2-4-16. Operator intends to install larger culvert pipe and add additional rock to AR near culvert area. Operator requested clarification on what, if any, permits would be needed. Operator also hoped to have permit process expedited because of outstanding violation. Biologist Mike Stephan stated submitted plans would be reviewed, possibly expedited. Department requested final plans be submitted to WQS to ensure construction was being completed as permitted. A follow up inspection will be conducted at a later date. Previously issued violations s

2489652 Primary Facility 2016-05-27 Administrative/File Review Outstanding Violations - No Viols Req'd Admin inspection to inspection record # 2448023 where violations issued for failure to maintain BMP's and failure to minimize erosion/sedimentation.

Department received GP-7 from Operator on 5-27-16. DEP Biologists are in the process of reviewing the permit.

2493413 Primary Facility 2016-06-09 Administrative/File Review Outstanding Violations - No Viols Req'd Admin inspection to inspection record # 2448023 where violations issued for failure to maintain BMP's and failure to minimize erosion/sedimentation.

Operator submitted GP-7 to Southwest District Office Oil and Gas Operations Tech Services on 5-9-16. After a technical review of the GP-7 DEP Biologist Supervisor Mike Stephan recommended on 6-10-16 that the GP-7 be withdrawn and Operator submit a PASPGP-4 with a Waiver letter to the Army Corps of Engineers. Department awaiting Operator response. UPDATE: 6-13-16: Operator responded to Biologist via e-mail requesting the GP-7 be withdrawn and will proceed with the PASPGP-4.

2500644 Primary Facility 2016-07-08 Administrative/File Review In Compliance with Policy ADMIN inspection to inspection record #2448023 where violations were issued for failure to maintain BMP’s and failure to minimize erosion and sedimentation.

Department contacted Operator Rep Richie Vrobel by phone to request update on status of culvert pipe replacement. Mr. Vrobel stated he was at the site this past Tuesday (7-5-16) for a site meeting with contractors. Bids on the replacement of the culvert pipe are due on 7-12-16. He hopes work will begin in 3-4 weeks. Department requested copy of permit CNX received. Mr. Vrobel stated he would e-mail a copy to Department. UPDATE: Department received copy of PASPGP-4 via e-mail. A follow up inspection will be conducted at a later date to ensure permit requirements are being met. Previously issued violations for this site have been scheduled for correction. Operator appears to be In Compliance with Policy at this time.

2508702 Primary Facility 2016-08-05 Administrative/File Review Outstanding Violations - No Viols Req'd Admin Inspection to inspection record # 2448023 where violations issued for failure to maintain BMP's and failure to minimize erosion/sedimentation.

Operator Rep Richy Vrobel contacted Department by e-mail. Mr. Vrobel stated that construction on the culvert pipe and access road will begin 8-17-16, weather permitting. Previously issued violations still exist for this site. A follow up inspection will be conducted at a later date.

2512695 Primary Facility 2016-08-15 Administrative/File Review Outstanding Violations - No Viols Req'd Admin Inspection to inspection record # 2448023 where violations issued for failure to maintain BMP's and failure to minimize erosion/sedimentation.

Operator Rep Richy Vrobel contacted Department by e-mail. Mr. Vrobel stated that construction on the culvert pipe and access road will begin 'next week' instead of on 8-17-16 due to heavy rains over the weekend. Previously issued violations still exist for this site. A follow up inspection will be conducted at a later date.

2520368 Primary Facility 2016-09-07 Compliance Evaluation No Violations Noted Compliance Evaluation Inspection to inspection record #2448023 where violations issued for Operator failure to maintain E&S BMP's.

At time of inspection E&S plan on site. Entrance to gated access road rocked. Temporary BMP's installed around disturbed area and area appears to be seeded and mulched. No E&S issues observed on access road. It appears an 18" culvert pipe has been installed and a stilling pool has been constructed at the inlet of the culvert pipe, matching the E&S plan, and the approved GP. According to E&S manual, stilling pool should be constructed at outlet of culvert pipe. However, GP was approved (see attached e-mail) with this BMP at the inlet, and a riprap apron at the outlet. Compost silt sock has been installed and appears adequate. Disturbed areas appear to be seeded and mulched. Department recommends Operator remove temporary BMP's when permanent stabilization has been achieved. A follow up inspection will be conducted to ensure permanent stabilization is achieved. Previously issued

2540937 Primary Facility 2016-11-29 Routine/Partial Inspection No Violations Noted Routine Partial inspection to inspection record #2448023.

At time of inspection E&S plan on site. No E&S issues observed on gated access road. Temporary BMP's (compost filter sock) still on site. Disturbed areas vegetated but do not appear to have reached >70% uniform vegetative growth. Department recommends Operator remove temporary BMP's once permanent stabilization has been achieved. Stilling basin and rip rap apron appear adequate. At this time no water is running through culvert pipe. A follow up inspection will be conducted to ensure permanent stabilization is achieved.

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
2448023 745454 2016-02-04 2016-09-07 78.53 Environmental Health & Safety
2448023 745455 2016-02-04 2016-09-07 102.11(a)1 Environmental Health & Safety

Penalties Applied

Violation ID Penalty ID Penalty Code Penalty Status Penalty Date Enforcement Date Penalty Amount Amount Collected
745454 334376 NOV - Notice of Violation 2016-11-09
745455 334376 NOV - Notice of Violation 2016-11-09