If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-063-24147 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.807822,"lon":-79.214574,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Indiana | |
Municipality: South Mahoning Township | |
Operator Name: EQT PROD CO | |
Well Pad ID: | |
Farm/Lease Name: D W RARAIGH 3253 | |
License Status: ACTIVE | |
Spud Date: 1940-01-04 | |
Permit Date: | |
Well Type: GAS | |
Unconventional Well: N | |
Configuration: Vertical Well | |
Conservation: No | |
Latitude: 40.807822 | |
Longitude: -79.214574 |
Date | Event |
---|---|
1940-02-23 | Drilling Completion |
1978-03-02 | OLD WELL |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
1991 | EQUITRANS INC | 5325.00 | 363 | 0.00 | 0 | 0.00 | 0 |
1992 | EQUITRANS INC | 1091.00 | 330 | 0.00 | 0 | 0.00 | 0 |
1993 | EQUITRANS INC | 3043.00 | 332 | 0.00 | 0 | 0.00 | 0 |
1994 | EQUITRANS INC | 2914.00 | 363 | 0.00 | 0 | 0.00 | 0 |
1995 | EQUITRANS INC | 2099.00 | 365 | 0.00 | 0 | 0.00 | 0 |
1996 | EQUITRANS INC | 1580 | 365 | 0.00 | 0 | 0.00 | 0 |
1997 | EQUITRANS INC | 2119 | 365 | 0.00 | 0 | 0.00 | 0 |
1998 | EQUITRANS INC | 2508 | 365 | 0.00 | 0 | 0.00 | 0 |
1999 | EQUITRANS LP | 1963 | 365 | 0.00 | 0 | 0.00 | 0 |
2000 | EQUITRANS INC | 1414 | 365 | 0.00 | 0 | 0.00 | 0 |
2001 | EQUITABLE PROD EASTERN STATES EXPLORATION INC | 1171 | 365 | 0.00 | 0 | 0.00 | 0 |
2003 | EQT PROD CO | 1166 | 365 | 0.00 | 0 | 0.00 | 0 |
2005 | EQUITRANS INC | 1166 | 365 | 0 | 365 | 0.00 | 0 |
2010 | EQUITRANS INC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2011 | EQUITRANS INC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2012 | EQUITRANS INC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2013 | EQUITRANS INC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2014 | EQUITRANS INC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2015 | EQUITRANS INC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2016 | EQUITRANS INC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2017 | EQUITRANS INC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2018 | EQT PROD CO | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
For data sources see[5]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2764644 | Primary Facility | 2018-08-17 | Plugging(Includes Plugged/Mined Through) | No Violations Noted | 8/16/18 - Location built, rig not on pad.
8/17/18 - Penn Mechanical preparing well before rig arrives. |
2764648 | Primary Facility | 2018-08-16 | Plugging(Includes Plugged/Mined Through) | No Violations Noted | 8/16/18 - Location built, rig not on pad. |
2765013 | Primary Facility | 2018-08-20 | Plugging(Includes Plugged/Mined Through) | No Violations Noted | 8/16/18 - Location built, rig not on pad.
8/17/18 - Penn Mechanical preparing well before rig arrives. 8/20/18 - Plugging operation has not started yet. No equipment on location. |
2766031 | Primary Facility | 2018-08-22 | Plugging(Includes Plugged/Mined Through) | No Violations Noted | 8/16/18 - Location built, rig not on pad.
8/17/18 - Penn Mechanical preparing well before rig arrives. 8/20/18 - Plugging operation has not started yet. No equipment on location. 8/22/18 - discussed with Penn Mechanical well head issues. |
2770087 | Primary Facility | 2018-08-30 | Plugging(Includes Plugged/Mined Through) | No Violations Noted | 8/16/18 - Location built, rig not on pad.
8/17/18 - Penn Mechanical preparing well before rig arrives. 8/20/18 - Plugging operation has not started yet. No equipment on location. 8/22/18 - discussed with Penn Mechanical well head issues. 8/30/18 - called attainable bottom @ 2613'. Set cmt. plug on bottom |
2770375 | Primary Facility | 2018-09-04 | Plugging(Includes Plugged/Mined Through) | No Violations Noted | 8/16/18 - Location built, rig not on pad.
8/17/18 - Penn Mechanical preparing well before rig arrives. 8/20/18 - Plugging operation has not started yet. No equipment on location. 8/22/18 - discussed with Penn Mechanical well head issues. 8/30/18 - called attainable bottom @ 2613'. Set cmt. plug on bottom. 9/4/18 - last cmt. plug came up into 3" csg. 700'. Going to start drilling cmt. out 9/5/18. |
2776276 | Primary Facility | 2018-09-18 | Plugging(Includes Plugged/Mined Through) | No Violations Noted | 8/16/18 - Location built, rig not on pad.
8/17/18 - Penn Mechanical preparing well before rig arrives. 8/20/18 - Plugging operation has not started yet. No equipment on location. 8/22/18 - discussed with Penn Mechanical well head issues. 8/30/18 - called attainable bottom @ 2613'. Set cmt. plug on bottom. 9/4/18 - last cmt. plug came up into 3" csg. 700'. Going to start drilling cmt. out 9/5/18. 9/18/18 - loading hole to bond log tomorrow. |
2776865 | Primary Facility | 2018-09-19 | Plugging(Includes Plugged/Mined Through) | No Violations Noted | 8/16/18 - Location built, rig not on pad.
8/17/18 - Penn Mechanical preparing well before rig arrives. 8/20/18 - Plugging operation has not started yet. No equipment on location. 8/22/18 - discussed with Penn Mechanical well head issues. 8/30/18 - called attainable bottom @ 2613'. Set cmt. plug on bottom. 9/4/18 - last cmt. plug came up into 3" csg. 700'. Going to start drilling cmt. out 9/5/18. 9/18/18 - loading hole to bond log tomorrow. 9/19/18 - Timco logged well, pipe appears to be free. Going to shoot 3" csg. around 1492'. |
2780008 | Primary Facility | 2018-09-26 | Plugging(Includes Plugged/Mined Through) | No Violations Noted | 8/16/18 - Location built, rig not on pad.
8/17/18 - Penn Mechanical preparing well before rig arrives. 8/20/18 - Plugging operation has not started yet. No equipment on location. 8/22/18 - discussed with Penn Mechanical well head issues. 8/30/18 - called attainable bottom @ 2613'. Set cmt. plug on bottom. 9/4/18 - last cmt. plug came up into 3" csg. 700'. Going to start drilling cmt. out 9/5/18. 9/18/18 - loading hole to bond log tomorrow. 9/19/18 - Timco logged well, pipe appears to be free. Going to shoot 3" csg. around 1492'. 9/26/18 - Cmt. well to surface. |
2782316 | Primary Facility | 2018-10-02 | Plugging(Includes Plugged/Mined Through) | No Violations Noted | 8/16/18 - Location built, rig not on pad.
8/17/18 - Penn Mechanical preparing well before rig arrives. 8/20/18 - Plugging operation has not started yet. No equipment on location. 8/22/18 - discussed with Penn Mechanical well head issues. 8/30/18 - called attainable bottom @ 2613'. Set cmt. plug on bottom. 9/4/18 - last cmt. plug came up into 3" csg. 700'. Going to start drilling cmt. out 9/5/18. 9/18/18 - loading hole to bond log tomorrow. 9/19/18 - Timco logged well, pipe appears to be free. Going to shoot 3" csg. around 1492'. 9/26/18 - Cmt. well to surface. 10/2/18 - Rig moved off location. Well plugged, monument attached. |
2782650 | Primary Facility | 2018-09-27 | Routine/Complete Inspection | No Violations Noted | Inspection conducted in response to a NOI to Plug a Well received by Department on 6-22-18.
E and S plan on site. No activity taking place on site at this time. At time of inspection well appears to be plugged. Temporary BMP's appear installed as per the E and S plan and appear to be functioning as intended. Department recommends operator continue to monitor and maintain BMP's due to the severe topography surrounding this site. Three roll off boxes on site. Wooden platform and equipment remain on site (photo #1). |
For data sources see[6]