37-063-36614

Well Details

Well ID: 37-063-36614
Loading map...
Country: United States
State: Pennsylvania
County: Indiana
Municipality: Conemaugh Township
Operator Name: ALLIANCE PETRO CO LLC
Well Pad ID:
Farm/Lease Name: L E LYONS 4
License Status:
Spud Date: 2009-11-18
Permit Date: 2009-07-30
Well Type: GAS
Unconventional Well: N
Configuration: Vertical Well
Conservation: No
Latitude: 40.490849
Longitude: -79.429791

For data sources see[1][2][3]

Well History

Date Event
2009-07-30 New Permit Application
2009-11-17 Performed Spud Operation
2009-11-25 Drilling Completion
2009-12-02 Perforation
2010-02-18 NEWLY DRILLED

For data sources see[4]


Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2009 PHILLIPS EXPLORATION INC 0.00 0 0.00 0 0.00 0
2010 PHILLIPS EXPLORATION INC 24,026.00 289 0.00 0 0.00 0
2011 PHILLIPS EXPLORATION INC 22,220.00 364 0.00 0 0.00 0
2012 XTO ENERGY INC 12,811.00 366 0.00 0 0.00 0
2013 XTO ENERGY INC 4,414.00 365 0.00 0 0.00 0
2014 XTO ENERGY INC 17,599.00 365 0.00 0 0.00 0
2015 XTO ENERGY INC 10,952.15 365 0.00 0 0.00 0
2016 XTO ENERGY INC 9,697.67 366 0.00 0 0.00 0
2017 ALLIANCE PETRO CO LLC 7,813.00 334 0.00 0 0.00 0
2018 ALLIANCE PETRO CO LLC 3,867.00 365 0.00 0 0.00 0
2019 ALLIANCE PETRO CO LLC 7,046.00 365 0.00 0 0.00 0

For data sources see[5]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2015 XTO ENERGY INC Produced Fluid 49 Bbl CENT WASTE TRT FAC NPDES PA0095273
2015 XTO ENERGY INC Produced Fluid 49.00 Bbl CENT WASTE TRT FAC NPDES DISCHARGE PA0095273

For data sources see[6]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1845224 Primary Facility 2009-11-19 Drilling/Alteration No Violations Noted Based on records, permit approved on 7/30/09. Rig set on well. No drilling occurred at the time of inspection. Pit containing 20 mil plastic. No freeboard issues. Based on site conditions, no indication of IW issues at the site. Well sign and E&S plan present. No E&S issues at the site. Filter fence located on down gradient side of pad has shown stress from sediment from site pad. It appears that the filter fence has fallen and area of drainage area has shown sediment on the down gradient side of fence. Inspector requested that the Water Quality personnel inspect site for further E&S evaluation.
1846430 Primary Facility 2009-11-23 Routine/Complete Inspection No Violations Noted Well was actively being drilled. Site was properly signed with E&S plan available. The pit sustained 2ft of freeboard and appeared sound in construction. The disturbed areas surrounding the well site were temporarily reseeded. Noted possible E&S concerns with filter fabric fence installed on the down slope side of the well pad, it is recommended that the BMP be maintained to ensure proper functioning stability. Observed that initial filter fence was overtopped with runoff and replaced with an additional fence. In order to prevent such an event from reoccurring a rocked interceptor ditch may be installed on well pad. Also noted that culvert pipe installed in access road directly before well pad was crushed and partially buried, it recommended that the culvert be maintained and/or replaced to ensure proper drainage techniques are sustained.At the time of inspection, accelerated erosion or sedimentation issues were not observed, but the above recommendations should be performed to prevent any such pollution event(s) in order to ensure compliance.
1954889 Primary Facility 2011-02-24 Routine/Complete Inspection No Violations Noted ANNULUS CLOSED , 100 BBL TANK ON LOC; SITE RESTORED
2092734 Primary Facility 2012-05-01 Routine/Complete Inspection No Violations Noted Gas well was in production. No E&S issues were present during the inspection.
2092784 Primary Facility 2012-05-15 Routine/Complete Inspection No Violations Noted system running and no e&S issues.

For data sources see[7]

References