If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-063-36701 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.432344,"lon":-79.090202,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Indiana | |
Municipality: West Wheatfield Township | |
Operator Name: PENNECO OIL CO INC | |
Well Pad ID: | |
Farm/Lease Name: FLORENCE MINING 3 | |
License Status: | |
Spud Date: 2009-12-09 | |
Permit Date: 2009-11-05 | |
Well Type: GAS | |
Unconventional Well: N | |
Configuration: Vertical Well | |
Conservation: No | |
Latitude: 40.432344 | |
Longitude: -79.090202 |
Date | Event |
---|---|
2009-11-05 | New Permit Application |
2009-12-08 | Performed Spud Operation |
2009-12-17 | Drilling Completion |
2009-12-22 | Perforation |
2010-09-28 | NEWLY DRILLED |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2009 | PENNECO OIL CO INC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2010 | PENNECO OIL CO INC | 4,186.00 | 213 | 0.00 | 0 | 0.00 | 0 |
2011 | PENNECO OIL CO INC | 4,963.00 | 334 | 0.00 | 0 | 0.00 | 0 |
2012 | PENNECO OIL CO INC | 2,998.00 | 336 | 0.00 | 0 | 0.00 | 0 |
2013 | PENNECO OIL CO INC | 473.00 | 212 | 0.00 | 0 | 0.00 | 0 |
2014 | PENNECO OIL CO INC | 1,588.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2015 | PENNECO OIL CO INC | 1,656.89 | 305 | 0.00 | 0 | 0.00 | 0 |
2016 | PENNECO OIL CO INC | 2,007.82 | 366 | 0.00 | 0 | 0.00 | 0 |
2017 | PENNECO OIL CO INC | 1,854.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2018 | PENNECO OIL CO INC | 1,478.48 | 121 | 0.00 | 0 | 0.00 | 0 |
2019 | PENNECO OIL CO INC | 981.28 | 242 | 0.00 | 0 | 0.00 | 0 |
For data sources see[5]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2010 | PENNECO OIL CO INC | Produced Fluid | 15.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0095443 |
2010 | PENNECO OIL CO INC | Fracing Fluid Waste | 1,170.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0091472 |
2013 | PENNECO OIL CO INC | Produced Fluid | 96.00 Bbl | CENT WASTE TRT FAC NPDES DISCHARGE | PA0095443 |
2013 | PENNECO OIL CO INC | Produced Fluid | 96 Bbl | CENT WASTE TRT FAC NPDES | PA0095443 |
2014 | PENNECO OIL CO INC | Produced Fluid | 127 Bbl | CENT WASTE TRT FAC NPDES | PA0095443 |
2014 | PENNECO OIL CO INC | Produced Fluid | 127.00 Bbl | CENT WASTE TRT FAC NPDES DISCHARGE | PA0095443 |
2015 | PENNECO OIL CO INC | Produced Fluid | 84 Bbl | CENT WASTE TRT FAC NPDES | PA0095443 |
2015 | PENNECO OIL CO INC | Produced Fluid | 84.00 Bbl | CENT WASTE TRT FAC NPDES DISCHARGE | PA0095443 |
2018 | PENNECO OIL CO INC | Produced Fluid | 75.00 Bbl | CENT WASTE TRT FAC NPDES DISCHARGE | PA0095273 |
2019 | PENNECO OIL CO INC | Produced Fluid | 80.00 Bbl | CENT WASTE TRT FAC NPDES DISCHARGE | PA0095273 |
For data sources see[6]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
1848827 | Primary Facility | 2009-12-08 | Drilling/Alteration | No Violations Noted | Well permit granted on 11/5/09. Spud called for 12/8/09. Pad completed. E&S controls were implemented. Well stake and pit dug. Well sign and E&S plan located at the entrance of site. At the time of inspection, no E&S issues or IW issues. |
1851523 | Primary Facility | 2009-12-22 | Routine/Complete Inspection | No Violations Noted | At the time of inspection, the well was drilled but not set for production. Site was properly signed with E&S plan available for review. Access road was in stable condition. No E&S concerns with access road or well pad. Bmps were properly installed and functioning. Noted two pits onsite, recommended that operator monitor the pit freeboard as levels were near the 2ft of freeboard. I also recommend the operator utilized better measures to secure pit liners in order to prevent a potential pollution event. Inspector Paul Wyrwas was also onsite at time of inspection and indicated that on 12/23/2009 operator had plans to frac the well. |
1851673 | Primary Facility | 2009-12-22 | Drilling/Alteration | No Violations Noted | Well permit granted on 11/5/09. Spud called for 12/8/09. Pad completed. Well completed to target depth. Titan wire Line Company present to run geophysical study. Hydro frac is scheduled for 12/23/09. Well head set at 8¿ to 4¿ reducer and shut off. E&S controls were implemented. Well sign and E&S plan located at the entrance of site. At the time of inspection, no E&S issues or IW issues. |
1941535 | Primary Facility | 2011-01-06 | Routine/Complete Inspection | No Violations Noted | Well head consisted of 8¿ pipe reduced to 4 ¿pipe reduced to 2¿ production line. No signs of leakage from well head. Production equipment consisted of heater, separator (200 psi) and 100 bbl brine tank (< 10 bbl fluid). At the time of inspection, no E&S and IW issues at the site. Totalized show 5366 MCF and 542 MCF. |
2102277 | Primary Facility | 2012-09-19 | Routine/Complete Inspection | No Violations Noted | At the time, no issues with E&S. Gas well was in productions. |
2318153 | Primary Facility | 2014-09-24 | Routine/Complete Inspection | No Violations Noted | At the time of inspection, no E&S or IW issues at the site. Gas well was in production. |
2503064 | Primary Facility | 2016-07-20 | Routine/Complete Inspection | No Violations Noted | system running. no issues |
2511817 | Primary Facility | 2016-08-16 | Routine/Complete Inspection | No Violations Noted | system running. no issues |
For data sources see[7]