{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.660081,"lon":-78.964083,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Indiana | |
Municipality: Cherryhill Township | |
Operator Name: EQT PROD CO | |
Well Pad ID: 149227 | |
Farm/Lease Name: ROYAL OIL & GAS 590693 | |
License Status: | |
Spud Date: | |
Permit Date: 2010-08-19 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: Yes | |
Latitude: 40.660081 | |
Longitude: -78.964083 |
Date | Event |
---|---|
2010-08-19 | New Permit Application |
2011-03-14 | Performed Spud Operation |
2011-04-23 | Drilling Completion |
2011-05-22 | Perforation |
2012-10-19 | DEVIATED |
For data sources see[4]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2011-05-29 | 2011-05-29 | 8,015 | 7,540,983 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | HCl | Halliburton | 15 HCl Acid | Propargyl Alcohol | 107-19-7 | 10.0 | 0.00019 | |
Methanol | 67-56-1 | 60.0 | 0.00115 | |||||
Hydrochloric Acid | 7647-01-0 | 28.0 | 0.11836 | |||||
FR-66 | Halliburton | Friction Reducer | Hydrotreated light petroleum distillate | 64742-47-8 | 30.0 | 0.03016 | ||
LP-65 | Halliburton | Scale Inhibitor | Ammonium chloride | 12125-02-9 | 10.0 | 0.00239 | ||
GBW-30 | Halliburton | Enzyme Breaker | Hemicellulase Enzyme | 9012-54-8 | 15.0 | 0.00017 | ||
BA-40L | Halliburton | Buffer | Potassium carbonate | 584-08-7 | 60.0 | 0.01536 | ||
HCl | Halliburton | Corrosion Inhibitor | ||||||
SP Breaker | Halliburton | Oxidizing Breaker | Sodium Persulfate | 7775-27-1 | 100.0 | 0.00093 | ||
BE-9 | Halliburton | Biocide | Tributyl tetradecyl phosphonium chloride | 81741-28-8 | 10.0 | 0.00445 | ||
LGC-36 | Halliburton | Gelling Agent | Guar Gum | 9000-30-0 | 30.0 | 0.03 | ||
Naptha, hydrotreated heavy | 64742-48-9 | 30.0 | 0.03 |
For data sources see[5]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2010 | EQT PROD CO | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2011 | EQT PROD CO | 148,446.00 | 30 | 0.00 | 0 | 0.00 | 0 |
2012 | EQT PROD CO | 641,937.00 | 366 | 0.00 | 0 | 0.00 | 0 |
2013 | EQT PROD CO | 410,875.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2014 | EQT PROD CO | 265,007.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2015 | EQT PROD CO | 199,384.00 | 363 | 0.00 | 0 | 0.00 | 0 |
2016 | EQT PROD CO | 224,559.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2017 | EQT PROD CO | 188,064.00 | 363 | 0.00 | 0 | 0.00 | 0 |
2018 | EQT PROD CO | 303,325.00 | 358 | 0.00 | 0 | 0.00 | 0 |
2019 | EQT PROD CO | 217,677.00 | 362 | 0.00 | 0 | 0.00 | 0 |
For data sources see[6]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2011 | EQT PROD CO | Drilling Fluid Waste | 1,540.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2011 | EQT PROD CO | Drilling Fluid Waste | 110.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR119 |
2011 | EQT PROD CO | Produced Fluid | 700.00 Bbl | INJECTION DISPOSAL WELL | 34-009-22704 |
2011 | EQT PROD CO | Drilling Fluid Waste | 715.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0095443 |
2011 | EQT PROD CO | Fracing Fluid Waste | 440.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2011 | EQT PROD CO | Produced Fluid | 3,989.00 Bbl | INJECTION DISPOSAL WELL | 34-083-24137 |
2011 | EQT PROD CO | Drilling Fluid Waste | 2,557.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | 301353 |
2012 | EQT PROD CO | Produced Fluid | 752.00 Bbl | INJECTION DISPOSAL WELL | 34-007-24355 |
2012 | EQT PROD CO | Produced Fluid | 224.00 Bbl | INJECTION DISPOSAL WELL | 34-167-29577 |
2012 | EQT PROD CO | Produced Fluid | 4,167.00 Bbl | INJECTION DISPOSAL WELL | 34-083-24137 |
2012 | EQT PROD CO | Produced Fluid | 2,600.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2012 | EQT PROD CO | Produced Fluid | 287.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | 525-1 |
2012 | EQT PROD CO | Produced Fluid | 465.00 Bbl | INJECTION DISPOSAL WELL | 34-121-2-3995 |
2012 | EQT PROD CO | Produced Fluid | 101.00 Bbl | INJECTION DISPOSAL WELL | 34-133-22523 |
2012 | EQT PROD CO | Produced Fluid | 292.00 Bbl | INJECTION DISPOSAL WELL | 34-121-23995 |
2012 | EQT PROD CO | Fracing Fluid Waste | 1,619.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2012 | EQT PROD CO | Produced Fluid | 479.00 Bbl | INJECTION DISPOSAL WELL | 34-167-28466 |
2013 | EQT PROD CO | Produced Fluid | 4,563.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2013 | EQT PROD CO | Produced Fluid | 589.00 Bbl | INJECTION DISPOSAL WELL | 34-155-21447 |
2013 | EQT PROD CO | Produced Fluid | 112.00 Bbl | INJECTION DISPOSAL WELL | 34-059-24067 |
2014 | EQT PROD CO | Produced Fluid | 2,030.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014 | EQT PROD CO | Produced Fluid | 109.00 Bbl | INJECTION DISPOSAL WELL | 34-155-24076 |
2014 | EQT PROD CO | Fracing Fluid Waste | 20.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2015 | EQT PROD CO | Produced Fluid | 66.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NW011 |
2015 | EQT PROD CO | Produced Fluid | 102.00 Bbl | INJECTION DISPOSAL WELL | 34-007-23262 |
2015 | EQT PROD CO | Produced Fluid | 100.00 Bbl | INJECTION DISPOSAL WELL | 34-157-25511 |
2015 | EQT PROD CO | Produced Fluid | 1,013.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016 | EQT PROD CO | Produced Fluid | 586.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016 | EQT PROD CO | Produced Fluid | 387.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NW011 |
2016 | EQT PROD CO | Produced Fluid | 55.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2016 | EQT PROD CO | Produced Fluid | 344.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW005 |
2017 | EQT PROD CO | Produced Fluid | 158.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2017 | EQT PROD CO | Produced Fluid | 912.00 Bbl | REUSE (AT WELL PAD) | |
2017 | EQT PROD CO | Produced Fluid | 176.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2018 | EQT PROD CO | Produced Fluid | 116.75 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW019 |
2018 | EQT PROD CO | Produced Fluid | 377.39 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2018 | EQT PROD CO | Produced Fluid | 1,935.50 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2018 | EQT PROD CO | Produced Fluid | 184.24 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW005 |
2018 | EQT PROD CO | Produced Fluid | 85.66 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW009 |
2018 | EQT PROD CO | Produced Fluid | 1,508.31 Bbl | REUSE (AT WELL PAD) | |
2019 | EQT PROD CO | Produced Fluid | 21.21 Bbl | INJECTION DISPOSAL WELL | 34-167-29543 |
2019 | EQT PROD CO | Produced Fluid | 21.70 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123 |
2019 | EQT PROD CO | Produced Fluid | 21.21 Bbl | INJECTION DISPOSAL WELL | 2D0859721 |
2019 | EQT PROD CO | Produced Fluid | 32.12 Bbl | RESIDUAL WASTE PROCESSING FACILITY | |
2019 | EQT PROD CO | Produced Fluid | 102.76 Bbl | INJECTION DISPOSAL WELL | 34-105-23619 |
2019 | EQT PROD CO | Produced Fluid | 30.12 Bbl | SURFACE IMPOUNDMENT | 95-7-37312-19 |
2019 | EQT PROD CO | Other Oil & Gas Wastes | 52.00 Bbl | REUSE (AT WELL PAD) | |
2019 | EQT PROD CO | Produced Fluid | 821.86 Bbl | REUSE (AT WELL PAD) | |
2019 | EQT PROD CO | Produced Fluid | 21.21 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | N/A |
2019 | EQT PROD CO | Produced Fluid | 65.62 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2019 | EQT PROD CO | Produced Fluid | 226.61 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW009 |
2019 | EQT PROD CO | Produced Fluid | 27.94 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW019 |
For data sources see[7]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
1958657 | Primary Facility | 2011-03-17 | Drilling/Alteration | No Violations Noted | |
1960595 | Primary Facility | 2011-03-23 | Drilling/Alteration | No Violations Noted | |
1962775 | Primary Facility | 2011-03-30 | Drilling/Alteration | No Violations Noted | |
1964918 | Primary Facility | 2011-04-06 | Drilling/Alteration | No Violations Noted | |
1969558 | Primary Facility | 2011-04-27 | Drilling/Alteration | No Violations Noted | |
1969559 | Primary Facility | 2011-04-29 | Drilling/Alteration | No Violations Noted | |
1972827 | Primary Facility | 2011-05-12 | Drilling/Alteration | No Violations Noted | |
2023891 | Primary Facility | 2011-11-22 | Routine/Complete Inspection | No Violations Noted | |
2037212 | Primary Facility | 2012-01-24 | Routine/Complete Inspection | No Violations Noted | well site Id sign & revised ES plan present with emergency contact information on signage. Access road stable. Multi well pad. Well drilled & equipped for production. Well spudded 3/08/11, drilling completed 4/23/11. 9 mnth restoration deadling 1/23/12. Bmp's installed according to plan and it appears that site has been stabilized with vegetative matting, although limited growth <70% uniform coverage observed. Final restoration could not be determined , well site is partially snow covered. A follow up will be conducted in future to evaluate final permanent site restoration.Ten brine tanks located onsite,surrounded by rock dike. Tanks appear structurally sound, noted hose connected to main discharge line (manifold) of all tanks, it is recommended that operator remove hose when not actively emptying tanks in order to prevent a possible pollution event or even acts of vandalism. No accelerated ES issues on pad/access road, but dept observed impaired filter fence which should be mainained. |
2054690 | Primary Facility | 2012-03-27 | Routine/Complete Inspection | No Violations Noted | Well sign(s) and tag(s) present. ES and ESCGP-1 onsite. Multi Well pad. Well(s) drilled and equipped for production. Drilling completed 4/23/11. |
2065689 | Primary Facility | 2012-05-03 | Site Restoration | No Violations Noted | Well sign(s) and tag(s) present. ES and ESCGP-1 onsite. Multi Well pad. Well(s) drilled and equipped for production. Drilling completed 4/23/11. |
2072697 | Primary Facility | 2012-05-30 | Routine/Complete Inspection | No Violations Noted | |
2081431 | Primary Facility | 2012-07-06 | Site Restoration | No Violations Noted | Well sign(s) and tag(s) present. ES and ESCGP-1 onsite. Multi Well pad. Well(s) drilled and equipped for production. Pad adequately rocked. Observed mini excavator onsite, not currently being utilized. |
2150586 | Primary Facility | 2013-03-19 | Routine/Complete Inspection | No Violations Noted | |
2227325 | Primary Facility | 2013-12-04 | Routine/Complete Inspection | No Violations Noted | Multi-well pad. Marcellus. Wells drilled and equipped for production. According to records, drilling completed on 4/23/2011. Well tag present, legible. |
2305492 | Primary Facility | 2014-09-17 | Routine/Complete Inspection | No Violations Noted | Multi-well pad. Marcellus. Wells drilled and equipped for production. According to records, drilling occurred 3/19/2011-4/23/2011. Well tag present, legible. |
2326750 | Primary Facility | 2014-12-02 | Routine/Complete Inspection | No Violations Noted | Multi-well pad. Marcellus. Wells drilled and equipped for production. According to records, drilling of 590693 occurred 3/19/2011-4/23/2011. Well tag present, legible. |
2335787 | Primary Facility | 2015-01-13 | Routine/Complete Inspection | No Violations Noted | Multi-well pad. Marcellus. Wells drilled and equipped for production. According to records, drilling of 590693 occurred 3/19/2011-4/23/2011. Well tag present, legible. |
2553738 | Primary Facility | 2017-01-09 | Administrative/File Review | In Compliance with Policy | SPILL. AT 1646 ON 1/9/17, A RELEASE OF 5 GALLONS GLYCOL ONTO THE PRODUCTION PAD WAS REPORTED TO FIRST CHOICE TAS BY OPERATOR REPRESENTATIVE COREY GILES. NO WATERWAYS REPORTED TO BE IMPACTED. RELEASE IS CURRENTLY BEING CLEANED UP. |
2553751 | Primary Facility | 2017-01-10 | Administrative/File Review | In Compliance with Policy | Admin inspection conducted in response to inspection ID 2553738 for the reported release of 5 gallons glycol.
Upon receipt of spill notification, Department contacted Operator representative Corey Giles via phone at 0818. According to Mr. Giles: A total release of 20 gallons glycol occurred – 15 gallons remained in secondary containment and 5 gallons was released outside of secondary containment. The spill resulted from a malfunctioning pressure relief valve, which caused the glycol to be released as a mist. The glycol did not come into contact with the ground as the pad was snow-covered and the glycol remained on the surface of the snow. Per Mr. Giles, the release was discovered yesterday (1/9/17) at 0215 by the well-tender while it was actively occurring. Mr. Giles stated that the visibly impacted snow was immediately removed and placed into drums for proper disposal. The Department is requesting that the Operator submit all disposal records/manifests for any wastes removed from the site in response to |
2553758 | Primary Facility | 2017-01-11 | Administrative/File Review | No Violations Noted | On-site inspection conducted in response to inspection ID 2553738 for the reported release of 5 gallons glycol.
At the time of this inspection, two Operator representatives currently on-site performing maintenance activities. According to the on-site Operator representatives: The glycol release occurred due to a “bad gasket”. Approximately 15 gallons of glycol dripped into secondary containment, while approximately 5 gallons of glycol misted out onto the snow outside of secondary containment. The impacted materials were removed and placed into a drum, which is currently on-site awaiting proper disposal. The well site was not snow-covered during this inspection. At this time, the Department did not observe any adverse environmental impact that may have resulted from this reported release of glycol. SDS for glycol available on-site. Site ID sign installed. Emergency Response Plan and PPC Plan available at access road entrance. Well tag present. According to records, drilling occurred 3/19/2011-4/23/2011. Fi |
2563260 | Primary Facility | 2017-02-06 | Administrative/File Review | In Compliance with Policy | Admin inspection conducted in response to inspection ID 2553738 for the reported release of 5 gallons glycol.
At 1537, Operator representative Corey Giles electronically provided the Department with the disposal records for the wastes that were reported to be disposed of in response to the 1/9/17 release of glycol at the site. |
2631996 | Primary Facility | 2017-09-05 | Complaint Inspection | No Violations Noted | Multi-well pad. At time of inspection, all five drilled wells on the pad appear equipped for production. |
2683001 | Primary Facility | 2018-01-17 | Routine/Partial Inspection | No Violations Noted | Routine partial inspection due to snow cover. Multi well Marcellus site. Well head surrounded by cement barriers. Five brine tanks on site. Contractors on site working on equipment on SW side of well pad. |
2837251 | Primary Facility | 2019-02-07 | Routine/Complete Inspection | No Violations Noted | On 2/7/19 at 1320 hrs., I conducted a routine inspection of EQT Production Co.'s Royal Oil & Gas 590693 well (API 063-36924) at the Diamondville Pad in Cherryhill Twp., Indiana County. There are 5 wells drilled and equipped for production. The well pad is permanently stabilized. The Emergency Response Plan and PPC Plan are located at the pad entrance. A site ID sign is posted and a well tag is affixed to the well head. There are no violations noted for this inspection. |
For data sources see[8]